Sensor: 2.75”H x 3.88”W x 1.5”D 
Compatible control panels: Qolsys IQ Panel 2 
Frequency: 319.5MHz 
Battery: 3V GP CR123A (x2) 
Operating Temperature: 14°F to 122°F 
Detection Range: 20ft Max and 5ft Min 
Intended for use with IQ Panel 2 
Supervisory signal interval: 70 min (approximately)

Intended for use with 3/16” and 1/4” plate or tempered 
glass.

SPECIFICATIONS

IQ GLASS S-LINE INSTALLATION MANUAL

Ceiling

Walls

Mounting Height:

 

The sensor should be mounted between 6.5ft and 8.5ft above the floor. 
All protected glass must be within a clear line of sight of the sensor and 
within the 20ft max range.

Ceiling mount

Wall mount

CHOOSE 
INSTALLATION 
LOCATION

STEP 

1

IQ GLASS-S

Note: for UL/cUL listed the device 
shall be secured using the provided 
mounting screws.

STEP 

2

STEP 

3

DETACH 
FACE 
PLATE

STEP 

4

STEP 

5

REPLACE  
FACE 
PLATE

SECURE 
TO 
SURFACE

REMOVE 
BATTERY 
TAB

Place your panel in 

“autolearn" mode

Open and close the case 

to “tamper” the device

Customize name and settings as 

desired and touch “ADD” 

ADD

STEP 

6

LEARN 
INTO 
PANEL

Note: Detector LED will flash rapidly for 5 
minutes as part of initial power up 
sequence.

Note: For UL/CUL installations use this device only in conjunction 

with compatible Qolsys wireless alarm system IQ Panel 2.