BK3254601-00  C

Third party information brought to

you courtesy of Dell EMC.

User’s Guide

Fibre Channel Adapter

QLE2740-DEL, QLE2740L-DEL,

QLE2742-DEL, and QLE2742L-DEL

Содержание QLE2740-DEL

Страница 1: ...BK3254601 00 C Third party information brought to you courtesy of Dell EMC User s Guide Fibre Channel Adapter QLE2740 DEL QLE2740L DEL QLE2742 DEL and QLE2742L DEL ...

Страница 2: ...port for RHEL 7 1 changed RHEL 6 6 to RHEL 6 8 and changed SLES 12 SP0 to SLES 12 SP2 For VMware added support for VMware ESXi 6 5 and removed support for ESXi 6 0 ESXi 5 5 U3 and ESXi 5 5 U2 Supported Operating Systems on page xv Added a reference to the Dell Update Packages Version xx xx xxx User s Guide as a prerequisite Running the Dell Update Package in the GUI on page 5 Deleted the Installat...

Страница 3: ...om ESXi 5 5 to ESXi 6 5 In the note changed from ESXi 6 0 to ESXi 6 0 U2 Installing the CIM Provider on an ESXi 6 5 or 6 0 U2 Host on page 27 Added a reference to the Dell Update Packages Version xx xx xxx User s Guide Using Dell Update Packages section Running the Firmware Update by Double Click ing on page 33 In Table 3 10 for the ESXi Driver row changed from ESXi 6 0 to ESXi 6 0 U2 Brocade Fabr...

Страница 4: ...Safety Precautions 1 Pre Installation Checklist 2 PCIe Bus Slot Considerations 2 Installing the Adapter 3 Connecting to the SAN 3 2 Driver Installation and Configuration Windows Driver Installation and Configuration 4 Running the Dell Update Package in the GUI 5 Running the Dell Update Package from the Command Line 11 Examples 11 Linux Driver Installation and Configuration 12 Installation Overview...

Страница 5: ...ng the QLogic Adapter CIM Provider 29 Installing QConvergeConsole VMware vSphere Web Client Plug in 30 Uninstalling the QConvergeConsole VMware vCenter Server Plug in 31 3 Fibre Channel Configuration Updating the Dell Firmware 33 Running the Firmware Update by Double Clicking 33 Running the Firmware Update from the Command Line 35 Using Fast UTIL for Custom Configuration 36 Configuration Settings ...

Страница 6: ...ConvergeConsole CLI 47 Configuring NPIV Quality of Service 48 Setting QoS by Bandwidth 49 Setting QoS by Priority 52 Configuring Fibre Channel Driver Parameters 53 Configuring Fibre Channel Driver Parameters with QConvergeConsole GUI 53 Configuring Fibre Channel Driver Parameters with Interactive QConvergeConsole CLI 53 Configuring Fibre Channel Driver Parameters with Noninteractive QConvergeConso...

Страница 7: ...gned Boot LUN with Noninteractive QConvergeConsole CLI 74 Using a Fabric Assigned Boot LUN with QConvergeConsole Plug ins 75 Running Diagnostics Fibre Channel Ping and Trace Route 76 Pinging and Viewing Trace of Routing Using Topology Map 76 Running a Fibre Channel CT Ping Test 77 Running a Fibre Channel CT Ping from QConvergeConsole GUI 77 Running a Fibre Channel CT Ping from QConvergeConsole CLI...

Страница 8: ...stics 98 Fibre Channel Diagnostics Using QConvergeConsole GUI 98 Fibre Channel Diagnostics Using Interactive QConvergeConsole CLI 100 Fibre Channel Diagnostics Using Noninteractive QConvergeConsole CLI 100 Fibre Channel Troubleshooting Diagram 101 Troubleshooting with a Diagnostic Port D_Port 102 Configuring D_Port on a Brocade Fibre Channel 16G or 32G Switch 103 Checking D_Port Results from a Bro...

Страница 9: ...Installing the Agents Using the Built in Agent Installer 112 Installing QConvergeConsole GUI 112 Installing QConvergeConsole in a Windows Environment 113 Installing QConvergeConsole in a Linux Environment 114 Installing QConvergeConsole in Silent Mode 115 What Is in the QConvergeConsole Help System 115 D Regulatory Information Warranty 117 Regulatory and Compliance Information 117 Laser Safety FDA...

Страница 10: ...ded Audience This guide is intended for system administrators and other technical staff members responsible for configuring and managing adapters installed on Dell PowerEdge servers in Windows Linux or VMware environments User s Guide Content This guide provides information in the following chapters and appendices Chapter 1 Hardware Installation covers the hardware and software requirements safety...

Страница 11: ...le Web management interface Appendix D Regulatory Information provides warranty regulatory and compliance information Related Materials For additional information refer to the following QLogic documents QConvergeConsole Help available through QConvergeConsole GUI provides help topics on configuring and managing host servers and adapters using QConvergeConsole GUI Installation Guide QConvergeConsol...

Страница 12: ...u items buttons check boxes or column headings For example Click Start point to Programs point to Accessories and then click Command Prompt Under Notification Options select the Warning Alarms check box Text in Courier font indicates a file name directory path or command line text For example To return to the root directory from anywhere in the file structure type cd root and then press the ENTER ...

Страница 13: ...st specify For example hba instance square brackets indicate an optional parameter For example file_name means specify a file name or omit it to select the default file name vertical bar indicates mutually exclusive options select one option only For example on off 1 2 3 4 ellipsis indicates that the preceding item may be repeated For example x means one or more instances of x x means zero or more...

Страница 14: ... profile Gen6 32Gb dual port Fibre Channel PCIe adapter with a full height bracket installed QLE2742L DEL A low profile Gen6 32Gb dual port Fibre Channel PCIe adapter with a low profile bracket installed Key Features Key features of the adapters include Centralized device management for SAN Connectivity to 32Gb 16Gb 8Gb Fibre Channel networks PCIe 3 0 x8 Full hardware offload for the Fibre Channel...

Страница 15: ...Linux Red Hat Enterprise Linux RHEL 7 3 RHEL 7 2 RHEL 6 8 RHEL 6 7 SUSE Linux Enterprise Server SLES 12 SP2 SLES 12 SP1 SLES 11 SP4 VMware vSphere VMware ESXi 6 5 vSphere VMware ESXi 6 0 U2 Citrix XenServer Citrix XenServer 6 5 NOTE Because the Dell Update Packages Version xx xx xxx User s Guide is not updated in the same cycle as this Fibre Channel adapter user s guide consider the operating syst...

Страница 16: ... operating systems firmware versions adapter drivers and utilities refer to the product release notes Safety Precautions For your safety follow these precautions Remove any metallic objects or jewelry from your hands and wrists Make sure to use only insulated or nonconducting tools Before you touch internal components verify that the system is powered OFF and is unplugged Install or remove adapter...

Страница 17: ... to achieve line rates NOTE If you acquired the adapter software on a disk or from the Dell support Web site http support dell com verify the path to the adapter driver files Table 1 1 Approximate Speed Throughput per Bus Slot Size Slot Size PCIe Generation Speed Throughput PCIe Gen1 2 5 GT s PCIe 2 0 5 GT s PCIe 3 0 8 GT s x8 slot 20Gbps 2 5 8 40Gbps 5 8 64Gbps 8 8 x16 slot 40Gbps 2 5 16 80Gbps 5...

Страница 18: ... see PCIe Bus Slot Considerations on page 2 4 Pull out the slot cover if any 5 Grasp the adapter by the top edge and seat it firmly into the appropriate slot 6 Refasten the adapter s retaining bracket 7 Close the computer cover 8 Plug the Fibre Channel cable into the adapter 9 Plug in the power cable and turn on the computer For more detailed information refer to the Hardware Owner s Manual for yo...

Страница 19: ...d to update the Flash memory of multiple adapters simultaneously For QConvergeConsole GUI refer to the Update the Flash Using the Flash Update Wizard topic in the QConvergeConsole Help For QConvergeConsole CLI issue the flashsupport command to update the Flash memory for all cards supported by the specified file For example qaucli pr nic flashsupport i ALL a p3p11179 bin NOTE When you disable the ...

Страница 20: ...ll Update Packages Version xx xx xxx User s Guide Prerequisites and Features for Systems Running Windows section To run the Dell update package in the GUI 1 Double click the icon representing the Dell update package file 2 In the Dell Update Package window Figure 2 1 click Install Figure 2 1 Dell Update Package Window NOTE The actual file name of the Dell update package varies ...

Страница 21: ...gic Super Installer InstallShield Wizard s Welcome window Figure 2 2 click Next Figure 2 2 QLogic InstallShield Wizard Welcome Window 4 In the wizard s License Agreement window Figure 2 3 on page 7 a Read the QLogic End User Software License Agreement b To continue select I accept the terms in the license agreement ...

Страница 22: ...ck Next Figure 2 3 QLogic InstallShield Wizard License Agreement Window 5 Complete the wizard s Setup Type window Figure 2 4 as follows a Select one of the following setup types Click Complete to install all program features Click Custom to manually select the features to be installed b To continue click Next ...

Страница 23: ...stall By default all features are selected To change a feature s install setting click the icon next to it and then select one of the following options This feature will be installed on the local hard drive This setting marks the feature for installation without affecting any of its subfeatures This feature and all subfeatures will be installed on the local hard drive This setting marks the featur...

Страница 24: ...tion and Configuration 9 BK3254601 00 C b Click Next to continue Figure 2 5 InstallShield Wizard Custom Setup Window 7 In the InstallShield Wizard s Ready To Install window Figure 2 6 click Install Figure 2 6 InstallShield Wizard Ready to Install the Program Window ...

Страница 25: ...ompleted window appears Figure 2 7 Click Finish to dismiss the installer Figure 2 7 InstallShield Wizard Completed Window 9 In the Dell Update Package window Figure 2 8 on page 11 Complete indicates successful installation Optional To open the log file click View Log The log file shows the progress of the DUP installation any previous installed versions any error messages and other information abo...

Страница 26: ...and line with no options specified results in the same behavior as double clicking the icon representing the Dell update package To run the Dell update package from the command line C DUP_file_name EXE The following shows the syntax for specifying options to customize the Dell update package installation behavior DUP_file_name exe option1 value1 option2 value2 To display the GUI for guided install...

Страница 27: ...the Linux Fibre Channel Driver Installation Overview To install and configure the adapter drivers on a Linux system refer to the driver release notes readme and installation instructions included in the package Installing the Linux Fibre Channel Driver This section provides procedures for installing the Linux Fibre Channel driver for the following operating systems Building the Driver for RHEL 6 x...

Страница 28: ...river modules from the source code by executing the build sh script as follows extras build sh install The build sh script does the following Builds the driver ko files Copies the ko files to the appropriate lib modules kernel version extra qlgc qla2xxx directory Add the appropriate directive in the modprobe conf if applicable 3 Optional To manually load the driver issue the insmod or modprobe com...

Страница 29: ...ad the driver reboot the host Building the Driver for SLES 11 1 From the directory that contains the source driver file qla2xxx src vx xx xx xx 11 x k tgz issue the following commands tar xzvf qla2xxx src vx xx xx xx 11 x k tgz cd qla2xxx x xx xx xx xx xx k4 Where x xx xx xx xx xx is the applicable version number 2 Build and install the driver modules from the source code by executing the build sh...

Страница 30: ...uing the following commands cd boot cp initrd kernel version img initrd kernel version img bak mkinitrd 5 To load the driver reboot the host Building the Driver for SLES 12 1 From the directory that contains the source driver file qla2xxx src vx xx xx xx 12 x k tgz issue the following commands tar xzvf qla2xxx src vx xx xx xx 11 x k tgz cd qla2xxx x xx xx xx xx xx k4 Where x xx xx xx xx xx is the ...

Страница 31: ... each time the system boots rebuild the RAM disk to include the driver as follows a Create a backup copy of the RAMDISK image by issuing the following commands cd boot cp initramfs kernel version img initramfs kernel version img bak b Create the new RAMDISK by issuing the following command dracut f 5 To load the driver reboot the host VMware Driver Installation and Configuration This section provi...

Страница 32: ...r on page 18 Updating an Existing Driver or Installing a New Driver for an Existing ESXi 6 5 or 6 0 U2 Installation with esxcli To use the driver bundle offline bundle zip 1 Copy the driver bundle offline bundle zip to this ESXi host 2 Install the driver bundle offline bundle zip as follows a To create a temporary directory issue the following commands mkdir install cd install b Unzip the driver b...

Страница 33: ...5 VMware VMwareCertified 2011 09 21 Installing QConvergeConsole VMware vCenter Server Plug in To use QConvergeConsole VMware vCenter Server Plug in install the following software in this order 1 QConvergeConsole VMware vCenter Server Plug in on the vCenter Server 2 QLogic Adapter CIM Provider on the ESXi server The following sections explain how to install and uninstall the required software Insta...

Страница 34: ...vers hardware and software requirements operating system support supported features installation and removal instructions known issues and workarounds and support contact information release_notes txt This file is the Release Notes document that lists changes fixes known issues and release details For detailed information on installing the QConvergeConsole VMware vCenter Server Plug in refer to In...

Страница 35: ...figuration 20 BK3254601 00 C The InstallAnywhere wizard opens as shown in Figure 2 9 Figure 2 9 InstallAnywhere Initial Window 3 In the QLogic Adapter VI Plug in wizard s Introduction window see Figure 2 10 click Next Figure 2 10 QLogic Adapter VI Plug in Wizard Introduction ...

Страница 36: ...1 BK3254601 00 C Wait while the wizard configures the plug in see Figure 2 11 Figure 2 11 QLogic Adapter VI Plug in Wizard Configuring the Plug in 4 Select the installation directory and then click Install see Figure 2 12 Figure 2 12 QLogic Adapter VI Plug in Wizard Choose Install Folder ...

Страница 37: ...ation and Configuration VMware Driver Installation and Configuration 22 BK3254601 00 C Wait while the wizard performs the installation see Figure 2 13 Figure 2 13 QLogic Adapter VI Plug in Wizard Installing the Plug In ...

Страница 38: ...tion and Configuration VMware Driver Installation and Configuration 23 BK3254601 00 C 5 Type the requested information in the boxes then click Next see Figure 2 14 Figure 2 14 QLogic Adapter VI Plug in Wizard User Input ...

Страница 39: ... and Configuration VMware Driver Installation and Configuration 24 BK3254601 00 C Wait while the wizard finishes configuring the plug in see Figure 2 15 Figure 2 15 QLogic Adapter VI Plug in Wizard Configuration in Progress ...

Страница 40: ...restart the VMware Virtual Center Management Web services If the plug in is installed on a server other than the vCenter Server restart the Apache Tomcat service Plug in Unregistration from a Manual Install If you have performed a manual install of the QConvergeConsole VMware vCenter Server Plug in you must perform a manual uninstall before running the plug in Installation Wizard VMware provides t...

Страница 41: ...e VMware vCenter Server Plug in To remove the QConvergeConsole VMware vCenter Server Plug in 1 In the Windows Control Panel select Add or Remove Programs Windows Server 2008 or later only select Programs and Features 2 In the Add or Remove Programs dialog box select the QConvergeConsole VMware vCenter Server Plug in and then click Change Remove 3 To remove the plug in follow the instructions in th...

Страница 42: ...ds as follows cd esxcli software acceptance set level CommunitySupported esxcli software vib install d file offline bundle zip maintenance mode 3 Reboot the system as required Existing ESXi Installation Using VMware Update Manager An existing ESXi host has asynchronous drivers installed using VMware Update Manager VUM For more information see Using vSphere ESXi Image Builder CLI in the vSphere Ins...

Страница 43: ...ns to complete the installation You might need to reboot the ESXi system Subsequent Update Installation To update the QLogic Adapter CIM Provider after a prior VIB installation follow the instructions in Uninstalling the QLogic Adapter CIM Provider on page 29 to remove the existing VIB After completing the VIB removal use the same steps in Initial Installation Methods on page 27 to install the new...

Страница 44: ...bout removing the QLogic Adapter CIM Provider through a remote host see the QLogic Adapter CIM Provider and vCenter Plug in for VMware ESX ESXi Readme file Uninstalling the CIM Provider from an ESXi 5 x Host 1 To view the VIB list issue the following command esxcli software vib list 2 To remove the QLogic Adapter CIM Provider issue the following command esxcli software vib remove vibname qlogic ad...

Страница 45: ...to the appropriate directory 2 Run the installer on the server providing the Tomcat service Provide the information requested by the installer On Windows double click the installer and follow the instructions on the GUI provided On Linux a Make sure the user is the root user or has root privileges b Create the installer executable if one does not already exist Choose the installer for your system ...

Страница 46: ...ols menu select Services and then restart VMware vSphere Web Client On the vCenter Server Appliance Linux issue the following command etc init d vsphere client restart Uninstalling the QConvergeConsole VMware vCenter Server Plug in To uninstall the QConvergeConsole VMware vCenter Server Plug in refer to the procedure for Windows or Linux Windows Uninstalling the QConvergeConsole VMware vCenter Ser...

Страница 47: ...Configuring OoOFR on page 55 Configuring the UEFI Driver on page 56 Setting an FA PWWN on page 63 Configuring and Verifying FA BLD on page 68 Using a Fabric Assigned Boot LUN on page 73 Running Diagnostics Fibre Channel Ping and Trace Route on page 76 Configuring CS_CTL QoS on page 81 Configuring End to End CS_CTL QoS on page 84 Configuring FDMI on page 90 Enabling QLogic Forward Error Correction ...

Страница 48: ...ge from the command line which supports several command line options Running the Firmware Update by Double Clicking For additional information refer to the Dell Update Packages Version xx xx xxx User s Guide Using Dell Update Packages section To run the firmware Dell Update Package by double clicking the executable file 1 Double click the icon representing the firmware Dell Update Package file Whe...

Страница 49: ... C 2 Follow the installer instructions If a warning message appears Figure 3 2 click Yes to continue the installation Figure 3 2 Continue Dell Update Package Installation The installer indicates that it is loading the new firmware Figure 3 3 Figure 3 3 Loading New Firmware ...

Страница 50: ...omplete the installation click Finish Figure 3 5 Figure 3 5 Finish Installation Running the Firmware Update from the Command Line Running the firmware Dell update package from the command line with no options specified results in the same behavior as double clicking the icon representing the Dell update package Note that the actual file name of the Dell update package will vary C Network_Firmware_...

Страница 51: ...configuration of the adapters and connected devices using Fast UTIL the QLogic Fibre Channel Adapter BIOS utility in a pre OS environment To configure adapters using Fast UTIL 1 During the Host Bus Adapter BIOS initialization press ALT Q or CTRL Q It may take a few seconds for the Fast UTIL menu to appear 2 When the Select Host Adapter window appears select the adapter type 3 In the Adapter Settin...

Страница 52: ...Default Settings on page 40 Raw NVRAM Data on page 40 Advanced Adapter Settings on page 40 Adapter Settings Table 3 1 describes the adapter settings CAUTION If the configuration settings are incorrect your 2700 Series Adapter may not function properly Table 3 1 Adapter Settings Setting Values Default Description Host Bus Adapter BIOS Enabled Disabled Disabled Disabling this setting disables the RO...

Страница 53: ...enabled the adapter attempts to use the ID specified in this setting Connection Options 0 1 2 2 This setting defines the type of connection 0 loop only for the 8Gb data rate 1 point to point only for the 8Gb 16Gb and 32Gb data rate 2 loop preferred then point to point for the 8Gb and 16Gb data rate Fibre Channel Tape Support Enabled Disabled Enabled This setting enables FCP 2 recovery Data Rate 2 ...

Страница 54: ...nable or disable toggle the Selectable Boot option press the ENTER key To move to the Primary location of the Selectable Boot List menu press the DOWN ARROW key 5 To see a list of accessible devices in the Select Fibre Channel Device menu press ENTER 6 Select a drive by pressing the UP ARROW and DOWN ARROW keys or the PAGE UP and PAGE DOWN keys to scroll to the device that you want to put into you...

Страница 55: ...tem BIOS compatibility To boot from a QLogic host 2700 Series Adapter in a computer system with a multiboot system BIOS the 2700 Series Adapter must be included in the list of bootable devices in the system s Boot menu Table 3 3 Advanced Adapter Settings Setting Values Default Description LUNs per Target 0 8 16 32 64 128 256 128 This setting specifies the number of LUNs supported per target if the...

Страница 56: ...s setting specifies the number of seconds the software waits for a link that is down to come up Operation Mode 0 5 6 6 This setting specifies the reduced interrupt operation RIO modes if they are supported by the software driver The RIO modes allow posting multiple command completions in a single interrupt This setting supports the following modes 0 Interrupt for every I O completion 5 Interrupt w...

Страница 57: ...al loopback data test Internal loopback data test Select Adapter If you have a multiport or multiple 2700 Series Adapters in the system use the Select Adapter option to select and then configure or view the settings of a specific 2700 Series Adapter or one of its ports Exit Fast UTIL The Exit Fast UTIL option allows you to exit the utility and reboot the system After making changes to the 2700 Ser...

Страница 58: ...le Help Setting Fibre Channel Adapter Parameters with Interactive QConvergeConsole CLI To set Fibre Channel adapter parameters with interactive QConvergeConsole CLI 1 On the Fibre Channel Adapter Configuration menu select HBA Parameters 2 On the port menu select a port to open the HBA Parameters menu 3 On the HBA Parameters menu select the Configure HBA Parameters option to open the Configure Para...

Страница 59: ...then click the Target Persistent Binding tab 4 Choose the binding options Select the Bind All check box to bind all the devices listed to adapter ports Select the Bind check box if you want to configure a specific port and bind it to the target ID that you have selected from the Target ID list If you do not want to configure the port clear the check box If you clear the check box the corresponding...

Страница 60: ...Binding with Noninteractive QConvergeConsole CLI To bind a selected target to a specific adapter using the noninteractive mode of QConvergeConsole CLI issue the following command qaucli pr fc p hba instance hba wwpn target wwnn target wwpn target port id target id Where For more information refer to the section about Fibre Channel noninteractive commands in the User s Guide QConvergeConsole CLI pa...

Страница 61: ... interactive commands in the User s Guide QConvergeConsole CLI part number SN0054667 00 Configuring Boot Devices with Noninteractive QConvergeConsole CLI To set a specific target as the boot device for a specific adapter issue the following command qaucli pr fc e hba instance hba wwpn target wwnn target wwpn target id lun id Where For more information refer to the Fibre Channel Noninteractive Comm...

Страница 62: ...hen click Browse Contents To install QConvergeConsole GUI see Installing QConvergeConsole GUI on page 112 Configuring NPIV with Interactive QConvergeConsole CLI For information about using virtualization NPIV in the interactive mode of QConvergeConsole CLI refer to the User s Guide QConvergeConsole CLI part number SN0054667 00 To download the guide go to www qlogic com and click Downloads Configur...

Страница 63: ...ng the priority method or the bandwidth method but not both The priority method assigns priority levels low medium or high to virtual ports based on the quality of service required for the applications or VMs using the virtual port This method provides for various levels of latency requirements across virtual ports The bandwidth method assigns a bandwidth percentage 0 100 or a bandwidth rate for e...

Страница 64: ... allocates up to 80 percent of the physical port s bandwidth to its virtual ports The remaining 20 percent is reserved to handle non QoS applications and virtual ports Setting QoS by bandwidth guarantees bandwidth for each virtual port and to the application or virtual machine VM associated with that virtual port The proper QoS setting can prevent bottlenecks that occur when VMs contend for port b...

Страница 65: ...rtual ports The setting for a specific QoS can resolve bottlenecks that exist when VMs contend for port bandwidth To set the QoS by bandwidth percentage with QConvergeConsole GUI 1 In the QConvergeConsole system tree pane on the left expand a 2700 Series Adapter 2 Select a virtual port 3 In the content pane on the right click the QoS tab 4 In the QoS Type box select Bandwidth 5 In the View By box ...

Страница 66: ...k the QoS tab 4 In the QoS Type box select Bandwidth 5 In the View By box select Bandwidth Speed 6 Move the slider to select the bandwidth speed as shown in Figure 3 9 Figure 3 9 Setting the QoS by Bandwidth Speed 7 Click Save To set the QoS by bandwidth speed with interactive QConvergeConsole CLI 1 On the Fibre Channel Adapter Configuration menu select the QoS option 2 From the port menu select a...

Страница 67: ... the content pane on the right click the QoS tab 4 In the QoS Type box select Priority 5 Move the slider to select a low medium or high priority as shown in Figure 3 10 Figure 3 10 Setting the QoS by Priority 6 Click Save To set the QoS by priority with interactive QConvergeConsole CLI 1 From the Fibre Channel Adapter Configuration menu select the QoS option 2 From the port menu select a port to o...

Страница 68: ...ameters in the QConvergeConsole Help for information Configuring Fibre Channel Driver Parameters with Interactive QConvergeConsole CLI To configure Fibre Channel driver parameters using interactive QConvergeConsole CLI 1 On the Fibre Channel Adapter Configuration menu select HBA Parameters 2 On the port menu select a port to open the HBA Parameters menu 3 On the HBA Parameters menu select Configur...

Страница 69: ...QConvergeConsole plug in see the User s Guide QConvergeConsole Plug ins for VMware vSphere part number SN0054677 00 Configuring Selective LUNs The QConvergeConsole GUI cannot be used for configuring selective LUNs To configure selective LUNs with the interactive QConvergeConsole CLI refer to the section about the Fibre Channel interactive commands in the User s Guide QConvergeConsole CLI part numb...

Страница 70: ...ConvergeConsole system tree pane on the left select a Fibre Channel port 2 In the content pane on the right click Parameters 3 Click the Advanced HBA Parameters tab 4 Select the Enable Receive Out of Order Frame check box Configuring OoOFR with Interactive QConvergeConsole CLI To enable OoOFR with the interactive QConvergeConsole CLI 1 On the Fibre Channel Adapter Configuration menu select HBA Par...

Страница 71: ...me 0 qaucli n hba instance hba wwpn EO 0 Configuring the UEFI Driver This section provides information on configuring the unified extensible firmware interface UEFI driver contained in the multiboot image UEFI 2 x systems use a human interface infrastructure HII to configure motherboard devices and plug in adapters QLogic Fibre Channel Adapters use an HII to configure adapter parameters and boot f...

Страница 72: ...er name and WWPN of the port Figure 3 11 shows an example of the System Setup window for Device Settings Figure 3 11 Dell System Setup Device Settings 3 In the Device Settings window select your device and then press ENTER The Main Configuration Page for the selected device appears The Main Configuration Page is the top level menu of the adapter configuration pages Figure 3 12 shows an example of ...

Страница 73: ...figuration Page Table 3 4 Port Configuration Page Settings Setting Description Device Name Indicates the name of the adapter Port Number Indicates the index of the selected port 1 to N Figure 3 13 shows port 1 in a two port adapter Port Speed Indicates the data rate of the Fibre Channel adapter port This value can be automatic or specified in Gbps The adapters support 8Gbps 16Gbps and 32Gbps Port ...

Страница 74: ...port address information Figure 3 14 shows an example Figure 3 14 Dell System Setup Firmware and Device Information Virtual World Wide Node Name Indicates the adapter port s unique virtual WWNN World Wide Port Name Indicates the adapter port s unique WWPN Virtual World Wide Port Name Indicates the adapter port s unique virtual WWPN a Loop support is available only at port speeds up to and includin...

Страница 75: ... page appears Figure 3 15 shows an example Figure 3 15 Fibre Channel Target Configuration Table 3 5 Firmware and Device Information Settings Setting Description Chip Type Type of intelligent storage peripheral ISP controller used in the adapter PCI Device ID Unique PCI device ID of the adapter Bus Device Function PCI address of the adapter in the Bus Device Function BDF notation Family Firmware Ve...

Страница 76: ...on Boot Scan Selection Specifies the adapter initiator behavior for booting the system from the specified Fibre Channel storage target s or fabric discovered target s First FC Target World Wide Port Name Specifies the WWPN of the first Fibre Channel stor age target First FC Target LUN Specifies the LUN of the first Fibre Channel storage target Second FC Target World Wide Port Name Specifies the WW...

Страница 77: ...sables Fibre Channel protocol FCP 2 recovery Loop Reset Delay Specifies the Fibre Channel arbitrated loop reset delay for the port After resetting the loop the adapter firmware refrains from initiating any loop activity for the number of seconds specified The range is 0 to 60 Frame Payload Size Specifies the maximum Fibre Channel frame payload size Port Login Retry Count Specifies the number of ti...

Страница 78: ...set the FA PWWN using the following utilities Setting FA PWWN with QConvergeConsole GUI Setting FA PWWN with QConvergeConsole CLI Setting FA PWWN with QConvergeConsole VMware Plug ins Port Down Retry Count Specifies the number of seconds the software retries a command to a port returning port down status The range is 0 to 255 Link Down Timeout Specifies the number of milliseconds the Fibre Chan ne...

Страница 79: ...ge as shown in the example in Figure 3 17 Figure 3 17 Before Setting the FA PWWN in the GUI 1 In the QConvergeConsole GUI tree pane on the left select an adapter expand the adapter node and then select a port 2 In the content pane on the right click the Parameters tab 3 On the Parameters page click the Advanced HBA Parameters tab 4 Under Configure Port Advanced Parameters select the Enable Fabric ...

Страница 80: ...nu and then click Adapter Configuration 2 Select HBA Parameters 3 Select the appropriate port 4 Select Configuration HBA Parameters 5 Select Enable Fabric Assign WWN 6 On the Enable Fabric Assign WWN Menu select 1 Enable 7 Select the option to Commit Changes The following shows an example of setting the FA PWWN HBA Desc QLE2742 QLogic 2 port 32Gb Fibre Channel Adapter FW Version 7 04 00 WWPN 21 00...

Страница 81: ...u ex or 99 Quit Please enter selection 20 QConvergeConsole Version 1 1 3 Build 22 Enable Fabric Assign WWN Menu 1 Enable 2 Disable current p or 0 Previous Menu m or 98 Main Menu ex or 99 Quit Please enter selection 1 After refreshing the Brocade switch the Adapter Information shows the port name as shown in the following example QConvergeConsole CLI Version 1 1 3 Build 22 FC Adapter Information 1 ...

Страница 82: ... Channel Adapter Port in the User s Guide QConvergeConsole Plug ins for VMware vSphere part number SN0054677 00 Setting the FA PWWN from the Brocade Switch From the Brocade switch you can set a FA PWWN and a static FA PWWN For the most current information refer to the Brocade switch documentation Setting the FA PWWN from the Switch Figure 3 19 shows the FA PWWN setting from the Brocade switch Figu...

Страница 83: ...his section provides the following information on fabric assigned boot LUN discovery FA BLD Configuring FA BLD from the Adapter Verifying that FA BLD is Operational Adapter Side Restrictions Configuring FA BLD from the Adapter On the adapter side follow these procedures to configure fabric assigned boot LUN discovery FA BLD in the QConvergeConsole GUI and QConvergeConsole CLI Enabling Host Bus Ada...

Страница 84: ...ick Save Figure 3 23 shows an example Figure 3 23 Enabling Host Bus Adapter Port BIOS To enable fabric assigned boot LUN 1 In QConvergeConsole GUI select the Host tab in the left pane 2 In the system tree expand the adapter node and then select a port node 3 In the content pane on the right click the Parameters tab 4 On the Parameters page click the Boot Device Selection tab 5 Select the Enable Fa...

Страница 85: ... To configure adapter and boot devices 1 In QConvergeConsole CLI navigate to Adapter Configuration and then select HBA Parameters 2 Enter the port number 3 Select Configure HBA Parameters 4 Select Enable BIOS and set it to Enable 5 In the Adapter Configuration select Boot Device Configuration 6 Enter the port number 7 Select Configure Boot Device s 8 Set the Enable Fabric Assign Boot LUN to Enable...

Страница 86: ...switch 1 Create a boot LUN configuration as follows bootluncfg add 50 00 53 37 63 FA 00 05 20 02 00 11 0d 51 5c 01 0000000000000000 2 Create a zone named with the following Device s PWWN Specific information about the target WWN LUN to be booted from 3 Add a zone to the zoneset configuration as follows cfgadd config BFA_5000533763fa0005_BLUN 4 To save the zoneset issue the following command cfgsav...

Страница 87: ...xample of a configured zone in a Brocade switch Figure 3 26 Configuring a Zone in a Brocade Switch Verifying that FA BLD is Operational To verify if the FA BLD is operational use either Fast UTIL or the system Figure 3 27 shows Fast UTIL displaying the boot LUN Figure 3 27 Verifying FA BLD with Fast UTIL ...

Страница 88: ...e FA PWNN and FA BLD restrictions include the following Cannot be fully enabled from Fast UTIL Do not use Restore Defaults from Fast UTIL QConvergeConsole GUI or QConvergeConsole CLI Doing so causes these capabilities to become disabled Using a Fabric Assigned Boot LUN This section describes how to use a fabric assigned boot LUN in the following utilities Using a Fabric Assigned Boot LUN in QConve...

Страница 89: ...ibre Channel Adapter 2 On the Fibre Channel Adapter Configuration menu select Boot Devices Configuration appears 3 On the Boot Device Settings menu select Configure Boot Device s and then press the ENTER key 4 Select Enable Fabric Assigned Boot LUN and then press ENTER 5 On the Enable Fabric Assign Boot LUN menu type 1 to enable this feature Using a Fabric Assigned Boot LUN with Noninteractive QCo...

Страница 90: ...e part number SN0054677 00 To configure a 2700 Series Adapter boot device with QConvergeConsole VMware vCenter Server Plug in 1 In the QConvergeConsole VMware vCenter Server Plug in click the QConvergeConsole tab 2 In the tree pane on the left select a 2700 Series Adapter port 3 Click the Boot tab 4 On the Boot Device Selection page select the Enable Fabric Assigned Boot LUN check box Figure 3 29 ...

Страница 91: ...gy map uses the common transport CT layer to enable the adapter s initiator port to ping or run a trace route that will navigate across the environment through multiple ports of the switch or switches and to the target Table 3 8 compares the differences between the Ping Test CT Ping Test and the CT FTR Tests Table 3 8 Ping Test CT Ping Test and CT FTR Test Ping Test CT Ping Test CT FTR Test SCSI l...

Страница 92: ...e VMware plug ins as described in this section Running a Fibre Channel CT Ping from QConvergeConsole GUI To run a Fibre Channel CT ping test from QConvergeConsole GUI 1 In the QConvergeConsole GUI left pane click the Host tab 2 On the Host page expand the adapter node and then select a port 3 In the content pane on the right click the Diagnostics tab 4 On the Diagnostics page click the General Dia...

Страница 93: ... complete the Test Configuration options and then click CT Ping Test to start the test Figure 3 30 Running the Fibre Channel CT Ping Test A caution message appears for the diagnostic CT ping test Figure 3 31 Figure 3 31 CT Ping Test Caution 6 Ensure that the port has no active I O operations and then either click Yes to proceed or No to cancel the test ...

Страница 94: ...Loop Miscompare Failure Loss Loss CRC Status 01 0B 01 0 0 0 0 0 Success Running a Fibre Channel CT Ping from QConvergeConsole VMware Plug ins For information about running Fibre Channel CT ping from the QConvergeConsole VMware vCenter Server Plug in or QConvergeConsole VMware vSphere Web Client Plug in see the section Diagnostic Tests Fibre Channel Port in the User s Guide QConvergeConsole Plug in...

Страница 95: ...Console GUI The Fibre Channel trace route output from QConvergeConsole GUI shows a symbol of a red payload that starts from the host The travel across the route is also highlighted in red The payload enters and exits from the appropriate port on each switch as it traverses the path until it reaches the selected target The results appear as a success message output from the following QConvergeConso...

Страница 96: ...e GUI Setting the QoS Priority Level for a Virtual Port in QConvergeConsole GUI CS_CTL QoS Features The following highlights some of the features of the CS_CTL QoS Traffic priority classification for QLogic Gen6 Fibre Channel SAN QoS at the packet level is realized by using the CS_CTL field which is specified in the FC FS 2 specification QoS allows one to prioritize frames between a host and targe...

Страница 97: ... verify the CS_CTL mode setup for each port Figure 3 34 CS_CTL Mode Setup for Each Port Creating a Virtual Port from the Adapter s Port in QConvergeConsole GUI To create a virtual port in QConvergeConsole GUI 1 In the QConvergeConsole GUI content pane on the left select the Host tab 2 On the Host page expand the adapter node and then select a port 3 In the content pane on the right select the Virt...

Страница 98: ...3 Fibre Channel Configuration Configuring CS_CTL QoS 83 BK3254601 00 C Figure 3 35 shows how to create a virtual port from the adapter s port in QConvergeConsole GUI Figure 3 35 Creating a Virtual Port ...

Страница 99: ...rol CS_CTL QoS implementation is an end to end solution encompassing the initiator 2700 Series Adapters the switches and the target storage The 2700 Series Adapter stamps the priority value high medium low in the CS_CTL field of the Fibre Channel frame All three entities initiator switch and target honor this priority value at their respective levels NOTE By default the QoS of the physical port is...

Страница 100: ...wing command root configurechassis Configure 2 A list of attributes appear one at a time After either accepting the default or entering a different value the next attribute appears Press ENTER to accept the default for cfgload attributes Custom attributes and system attributes Type y for fos attributes Type 1 for CSCTL QoS Mode For example cfgload attributes yes y no n no Custom attributes yes y n...

Страница 101: ...indows To change the vPort priority levels in Windows you must first assign the vPorts and then change the priority levels Both procedures can be accomplished using either QConvergeConsole GUI or interactive QConvergeConsole CLI as described in the following sections For more detailed information see the QConvergeConsole Help and the User s Guide QConvergeConsole CLI part number SN0054667 00 Creat...

Страница 102: ...select Generate 6 To create the vPorts select Commit Changing the vPort Priority Level To change the vPort priority level using QConvergeConsole GUI 1 In the QConvergeConsole GUI left pane connect to the host that contains the 2700 Series Adapter whose vPort levels you want to change 2 Expand the host in the left pane by clicking the plus sign 3 Locate and expand the 2700 Series Adapter whose vPor...

Страница 103: ...u select Adapter Port 4 On the Adapter Port menu select QoS Priority 5 On the QoS Priority menu select Modify QoS Settings 6 Choose the priority value for the vPorts 7 Select Apply QoS Changing the Priority Levels in VMware ESXi To change the priority levels using either QConvergeConsole VMware vCenter Server Plug in or QConvergeConsole VMware vSphere Web Client Plug in 1 In the tree pane on the l...

Страница 104: ...vPort Priority Using QConvergeConsole Plug ins If vPort is not listed under QoS a Under QoS click Add b Set the QoS priority value by moving the corresponding slider c Enter the vPort WWPN d Click Save 7 Click Refresh to see the new QoS settings To remove a vPort priority 1 Under QoS locate the vPort whose priority you want to remove 2 Do one of the following Select the Delete check box of the vPo...

Страница 105: ...upported configuration for FDMI QLogic 2700 Series Adapters Brocade 16G and 32G switches with Fabric OS FOS v7 3 or higher This section provides the following information on the FDMI Brocade Switch FOS CLI Brocade Fabric Features FDMI Enhancements Support NOTE i Results can be viewed from Switch CLI If the Fibre Channel switch does not support FDMI 2 it falls back to FDMI 1 support ...

Страница 106: ...3 Fibre Channel Configuration Configuring FDMI 91 BK3254601 00 C Brocade Switch FOS CLI Figure 3 40 shows the FOS CLI of a Brocade switch Figure 3 40 FOS CLI of Brocade Switch ...

Страница 107: ...Console GUI QConvergeConsole CLI QConvergeConsole VMware vCenter Server Plug in No default setting Requires configuration on adapter FC Ping Ping a Fibre Channel N_Port or end device QConvergeConsole GUI QConvergeConsole CLI QConvergeConsole VMware vCenter Server Plug in Diagnostic test nothing to configure FC Trace Route Obtains the path infor mation between two F_Ports from the Fabric Configurat...

Страница 108: ... sample output of the fdmishow command Port attributes Device Name QLogic Adapter Node Name 20 00 00 0e 1e 80 af 80 Port Name 21 00 00 0e 1e 80 af 78 Port Type 0x5 Port Symbolic Name QLE8362 FW v7 04 00 DVR v9 1 12 20 Alpha 2 Class of Service 0x00000008 Fabric Name 10 00 00 05 33 8f 1a 49 FC4 Active Type 0x000001000000000000000000000000000000000000000000000000000 Port State 0x00000002 Discovered P...

Страница 109: ...9x DEL adapters FEC Process Overview The following highlights how the FEC process works between the transmitting and receiving device 1 Transmitter Device a Takes the incoming data stream b Inserts a redundant amount of parity bits of information on the data stream c Sends the data stream 2 Receiving Device a Receives the data stream b Checks for missing or corrupt data If there are no corrupt or ...

Страница 110: ...rection part number 83830 514 03 In Figure 3 41 the QConvergeConsole CLI interactive mode Adapter Information menu shows a port with an online FEC status Figure 3 41 QConvergeConsole CLI Adapter Information Menu FEC Status NOTE i Instead of having to request retransmission of the entire data frame the receiving device can recreate or reconstruct the data stream itself This process prevents multipl...

Страница 111: ...g the LCB SW6505 admin portpeerbeacon enable 12 SW6505 admin portpeerbeacon show all portPeerBeacon is enabled on port 12 SW6505 admin portpeerbeacon disable 12 Read Diagnostic Parameters Extended Link Service Command The following example shows the read diagnostic parameters extended link service RDP ELS command output for Port 13 on a Brocade 16G switch SW6505 admin sfpshow 13 link force Identif...

Страница 112: ...00 12 000 2 000 11 500 Voltage 3322 2 mVolts 3000 0 3600 0 3100 0 3500 0 RX Power 3 1 dBm 495 3uW 31 6 uW 1258 9 uW 31 6 uW 794 3 uW TX Power 3 2 dBm 481 6 uW 125 9 uW 1258 9 uW 251 2 uW 794 3 uW State transitions 5 Port Speed Capabilities 8Gbps 16Gbps 32Gbps PEER Port Gbic Info Laser Type Short Wave Laser SFP Type Optical Port Type Connecter Type Other Following SFP Parameters are Valid Temperatu...

Страница 113: ...ics Using QConvergeConsole GUI QConvergeConsole GUI supports the internal and external loopback read write buffer and beacon on off diagnostic tests for Fibre Channel ports To set the loopback or read write buffer test parameters 1 In the QConvergeConsole system tree select the adapter port 2 In the content pane on the right click the Diagnostics tab and then click the General Diagnostics tab 3 Fr...

Страница 114: ...r Stops the test sequence once an error is encountered Loop on Error Uses the same data pattern and test until the failure is cleared 7 In the Test Increment box type or select the number of passes you want to run before the test stops The valid range is between 1 and 10 000 and must be less than or equal to the value in the Number of Tests box see Step 5 For example if the Number of Tests box con...

Страница 115: ...er test or beacon test 1 On the Main Menu select 4 Adapter Diagnostics 2 On the Fibre Channel Diagnostics menu select the test type to run 1 Loopback Test to run the loopback test 2 Read Write Buffer Test to run the read write buffer test 3 Beacon Test to run the beacon test 4 Transceiver Diagnostics Monitoring Interface DMI to view the transceiver diagnostics information For more information refe...

Страница 116: ...ibre Channel Troubleshooting Diagram 101 BK3254601 00 C Fibre Channel Troubleshooting Diagram Figure A 1 and Figure A 2 provide a two part troubleshooting flowchart Figure A 1 Fibre Channel Troubleshooting Diagram 1 of 2 ...

Страница 117: ...witch firmware and a Brocade Fibre Channel switch feature license Fabric Vision Configure the diagnostic D_Port on the Brocade switch to dynamically allow a port to enter D_Port mode when a D_Port is configured on the switch end and then return to operational mode when the test is completed Also configure the switch to start and stop the diagnostic test on the adapter port See the Brocade switch d...

Страница 118: ...e QConvergeConsole utilities Configuring D_Port on a Brocade Fibre Channel 16G or 32G Switch Checking D_Port Results from a Brocade Fibre Channel 16G or 32G Switch Verifying D_Port Mode with QConvergeConsole GUI Verifying D_Port Mode with Interactive QConvergeConsole CLI Verifying D_Port Mode with Noninteractive QConvergeConsole CLI Verifying D_Port Mode with QConvergeConsole Plug ins Configuring ...

Страница 119: ...number issue the switchshow command switchshow The following example output identifies port 17 17 17 011100 id N16 Online FC D Port Loopback Port 17 2 Issue the portdporttest command as follows portdporttest show port_num For example portdporttest show 17 Following is an example output for this command portdporttest show 17 D Port Information Port 17 Remote WWPN 21 00 00 0e 1e 11 4a 31 Mode Automa...

Страница 120: ...nce 3 meters Buffers required 1 for 2112 byte frames at 16Gbps speed Verifying D_Port Mode with QConvergeConsole GUI To verify D_Port mode in QConvergeConsole GUI 1 In the QConvergeConsole left pane click the Host tab 2 On the Host page expand a 2700 Series Adapter to view its port nodes If a port is in D_Port mode the port node specifies Loop Down Diagnostic Mode Figure A 3 shows an example Figur...

Страница 121: ...then select the adapter type Fibre Channel Adapter 2 From the FC Adapter Information menu select 2 FC Port Information The Adapter Information menu shows the affected port with a status of Loop Down Diagnostic Mo Figure A 4 shows an example Figure A 4 D_Port Mode in Interactive QConvergeConsole CLI Verifying D_Port Mode with Noninteractive QConvergeConsole CLI To verify D_Port mode in noninteracti...

Страница 122: ...ormation refer to the section about the Fibre Channel noninteractive commands in the User s Guide QConvergeConsole CLI part number SN0054667 00 Verifying D_Port Mode with QConvergeConsole Plug ins For information about verifying D_Port mode using QConvergeConsole VMware vCenter Server Plug in and QConvergeConsole VMware vSphere Web Client Plug in see the Fibre Channel Adapter Management section in...

Страница 123: ...cal Characteristics Adapter Type Bracket Installed Length Width QLE2740 DEL Low profile PCIe card Full height 6 6 inches 2 731 inches QLE2740L DEL Low profile PCIe card Low profile 6 6 inches 2 731 inches QLE2742 DEL Low profile PCIe card Full height 6 6 inches 2 731 inches QLE2742L DEL Low profile PCIe card Low profile 6 6 inches 2 731 inches Table B 2 Power Requirements Adapter Nominal Power Max...

Страница 124: ...2 Second Generation FC Generic Services FC GS 2 Third Generation FC Generic Services FC GS 3 Interface Specifications Table B 3 list the interface specifications for the QLE274x DEL Adapters Environmental Specifications Table B 4 lists the environmental specifications for the QLE274x DEL Adapters Table B 3 Interface Specifications Port Type Media 32Gb SFP SFF 8431 Specification for SFP Revision 3 ...

Страница 125: ...geConsole GUI is launched on the application server you can connect to QConvergeConsole GUI through a browser either locally on the server or remotely from another computer Your browser window becomes the client used to connect to servers that host the QLogic adapters and connected storage devices within the network Use the QConvergeConsole GUI main window to connect to servers that host QLogic ad...

Страница 126: ...ons see the QConvergeConsole Readme which you can download at http driverdownloads qlogic com Downloading QConvergeConsole Documentation To download the Installation Guide QConvergeConsole GUI part number SN0051105 00 go to www qlogic com and click Downloads Downloading and Installing Management Agents To manage the adapters on a local or remote host the management agents also called agents used b...

Страница 127: ...ng the Built in Agent Installer To access the QCC Agent Installer within QConvergeConsole GUI 1 Point to the gear icon point to Help and then click Download Agent Installers The QCC Agent Installer Utility opens in a separate window and lists links for the platform that the utility has detected 2 For each agent installer to download click the link 3 In the File Download dialog box click Save Insta...

Страница 128: ...t a localhost only installation If you do not want a localhost only installation select No 5 In the Pre Installation Summary dialog box verify that the information is correct and then click Install to proceed The installer displays the progress of the installation A message box prompts you to confirm if you want to enable the SSL feature which allows data to be encrypted within a secure layer befo...

Страница 129: ...e has permission to execute by issuing the ls lt command at the prompt 3 To install QConvergeConsole double click the QConvergeConsole installer bin file A prompt asks if you want to run or view the contents of the bin file 4 Click Run in Terminal The installer extracts the files and installs QConvergeConsole in the following directory opt QLogic_Corporation QConvergeConsole The InstallAnywhere wi...

Страница 130: ...ws how to start using QConvergeConsole and the help system It also describes how to initiate automatic e mail notifications and set security on adapters installed for a selected host Managing Host Connections describes how to connect to a host create and use a host group view host information and disconnect from one or more host servers Displaying Host Information describes how to view general hos...

Страница 131: ...anagement pages for Series Intelligent Ethernet Adapters as well as 8100 8200 Series Converged Network Adapters Using the Wizards describes how to use QConvergeConsole wizards to update the following Flash drivers NIC parameters Fibre Channel and FCoE parameters parameters files passwords and agents Troubleshooting describes tools you can use to resolve the problems that can occur when installing ...

Страница 132: ...llowing section contains a summary of EMI EMC test specifications performed on model HD8310405 and CU0310421 to comply with radiated emission radiated immunity and product safety standards Class 1 Laser Product Caution Class 1 laser radiation when open Do not view directly with optical instruments Appareil laser de classe 1 Attention Radiation laser de classe 1 Ne pas regarder directement avec des...

Страница 133: ... Class A EN55024 2010 EN61000 3 2 2006 A1 A2 2009 EN61000 3 3 2008 EN61000 4 2 ESD EN61000 4 3 RF Electro Magnetic Field EN61000 4 4 Fast Transient Burst EN61000 4 5 Fast Surge Common Differential EN61000 4 6 RF Conducted Susceptibility EN61000 4 8 Power Frequency Magnetic Field EN61000 4 11 Voltage Dips and Interrupt VCCI 20011 04 Class A AS NZS CISPR 22 2009 A1 2010 Class A Korea Certification K...

Страница 134: ...only with listed ITE or equivalent Complies with 21 CFR 1040 10 and 1040 11 Complies with 21 CFR 1040 10 and 1040 11 For use with UL Listed Servers or equivalent Power off the computer and all attached devices such as monitors printers and external components before installing the accessory card or equivalent 2006 95 EC Low Voltage Directive TUV EN60950 1 2006 A11 A1 A12 2nd Edition TUV IEC 60950 ...

Страница 135: ... trademarks of Google Inc IBM is a registered trademark of International Business Machines Corporation Linux is a registered trademark of Linus Torvalds Microsoft Hyper V Internet Explorer Windows and Windows Server are registered trademarks of Microsoft Corporation Mozilla and Firefox are registered trademarks of the Mozilla Foundation Novell SLES and SUSE are registered trademarks of Novell Inc ...