![Qimarox PRORUNNER mk9 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/qimarox/prorunner-mk9/prorunner-mk9_user-manual_765757022.webp)
Description
22
UM-PRORUNNER_mk9-2.0-EN
4.6
Specifications
The information below, the machine layout drawing, the specification sheet and the
identification plate give the specifications for the transportation of products.
4.6.1
Product transport specifications
Data concerning product type, dimensions, stability and weights must always be verified
with Qimarox.
When permitted weight and distance deviate from the specifications in the machine layout
drawing, the machine must be adjusted to accommodate this. These type of adjustments
may only carried out by Qimarox or after written permission from Qimarox has been
obtained.
If Qimarox does not supply the product conveyor, the weight of the applied conveyor
needs to be checked by Qimarox to determine the correct drive on the vertical movement.
4.6.2
Environmental specifications
The surrounding area of the machine must comply to the following specifications:
/i
When the specifications for the surrounding area deviate from the table above, the
machine must be adjusted to this. Such adjustments shall always be carried out by
Qimarox or after permission from Qimarox.
4.6.3
Electrical specifications
See the type plate. Refer to section
and the electrical circuit diagrams.
Motor
The motor can be connected directly or through an operating switch in the main switch
box. The machine must be controlled with a frequency inverter to ensure a smooth start
and stop movement and to reduce speed.
The motor safety relays must meet EN-IEC 60204-1 specifications. The setting range
depends on the motor specifications.
Property
Description
General
Covered and normally clean for operation. There must be suffi-
cient space around the machine for carrying out maintenance
and other activities on the machine.
Relative air humidity
Maximum 80%.
Temperature
B5°C (41 F) and 40°C (104 F).
Floor
Even. The floor load is given in the machine layout drawing and
specification sheet.
Required height
Refer to the machine layout drawing and specification sheet.
Compressed air
Between 5 bar and 7 bar in accordance with ISO 85731:2010
[7:4:4]