Operating
screens
Operating manual HR9
– QS203263
75
Manual control supply conveyor
The following can be operated in this screen:
Dosing conveyor
Turn conveyor
All relevant sensors are shown with a picture of the relevant sensor and a short description.
When it turns green, the sensor enters the PLC
The lightgrid beams are shown on this screen as well. A teach-in can be performed for the
lightgrid in this screen. By using the beam alignment help and getting the first, last and
weakest beam to 100% a good quality teach-in will be ensured.
These are the instructions for performing a teach in:
-
Press enable(Enable beam alignment). The enable button will turn light green and the
enabled led will blink orange.
-
Align the lightgrids until the first, last and weakest beam are 100%
-
Press enable again.(Disable beam alignment)
-
The button start will appear in the lightgrid teach-in windows. Press start to perform
the teach-in.