COMPANY REG.: 6535355
VAT NO.: GB 936 5596 78
Operator Instructions
Page 2 of 4
MK731
Digital Combination Lock
The lock has a 10 button keypad , a
*
button and a # button.
The lock has three code levels that allow you to perform the following
actions:
o
Master code(8 digit code)
o
Sub-master code(8 digit code)
o
User code(4 digit code)
Default Settings
Master code = 20050330 (8 digit code)
User code =1111 (4 digit code)
Private Mode
Functions
Before programming, select the most appropriate function for the
application:
A) Private Mode
or
A) Public Mode
Private Mode
Note: this is the default function and is already pre-programmed into
each lock. This is the most common
mode and is used where the same code will be repeatedly used.
To set to Private Mode: * -- Master code - -#--07--#
Example: * - 20050330 - -#--07--#
Result: The lock will revert back to default Private Mode, factory set user
code 1111 will now work until reprogrammed.
Public Mode
This function is used for short term, multi user applications. The code is
only used one time
To set to Public Mode: * -- Master code - -#--06--#
Result: the lock will now remain open until next user enters their own
code into the lock as follow:
Step 1: enter new user code --Close the locker which will now be locked
Step 2: enter user code-- The lock will now remain open until next 4 digit
code is entered
Содержание Qi730