QIAgility Software
5-146
QIAgility User Manual 11/2011
3.
Select the desired COM port from the drop-down menu
and then click on the “OK” button.
Note
: The software lists only eligible COM ports and
marks the mostly likely port on which the instrument can
be found with an asterisk (*). For correct communication
of the laptop (supplied with the QIAgility) with the
instrument:
Select COM1 if you are using RS-232 (recommended)
Select COM4 if you are using USB
4.
The following message will appear.
5.
Click on the “Yes” button to shut down the software.
6.
Restart the software.
5.12
Service register
The service register describes the current status of
maintenance alert notification records that are associated
with the instrument. The software maintains a schedule of
required service activities in the service register.
Maintenance activities that are scheduled for future dates are
displayed as green records. When a scheduled maintenance
activity is due, the record is displayed in red, and a service
alert notification is generated.
If the system has any unacknowledged service alert
notifications, the icon in the toolbar is marked with a red
exclamation mark.
Service alert notifications can be acknowledged by an
operator, using the “Service Register” dialog box.
To view the “Service Register” dialog box:
1.
Select “Options/Robot Setup/Service register”.
2.
The “Service Register” dialog box will appear.
Содержание QIAgility
Страница 10: ...Contents Contents 8 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 20: ...Safety Information 1 10 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 40: ...General Description 3 16 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 62: ...Installation Procedures 4 22 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 211: ...QIAgility Software QIAgility User Manual 11 2011 5 149...
Страница 212: ...QIAgility Software 5 150 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 254: ...Instrument Setup and Calibration 7 20 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 260: ...Maintenance Procedures 8 6 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 274: ...Troubleshooting 9 14 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 278: ...Glossary 10 4 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 284: ...Appendix A A 6 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 286: ...Appendix B B 2 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 298: ...Appendix C C 12 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 326: ...Appendix G G 4 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 328: ...Appendix H H 2 QIAgility User Manual 11 2011 This page intentionally left blank...
Страница 332: ...Index Index 4 QIAgility User Manual 11 2011 This page intentionally left blank...