Qiagen Q-Base Скачать руководство пользователя страница 29

 
 

 
 

Q-Base User Manual   03/2019 

29 

Select an instrument icon to open the detailed instrument screen. 

 

The status information is automatically updated every 20 seconds. 

5.2

 

Run setup 

Run setup allows preparation of an instrument run using the QIAcube Connect App on the tablet 
instead of the QIAcube Connect touchscreen. All run setup information will be displayed in the app 
in the same way as it is displayed on the instrument touchscreen. Run setup allows selection of all 
protocols, either manually, or by scanning the kit bar code, or by selecting a favorite protocol. 

 

Содержание Q-Base

Страница 1: ...Sample to Insight__ March 2019 Q Base User Manual...

Страница 2: ...our network 9 4 4 Connecting additional tablets to an existing Q Base 22 4 5 Administration of Q Base via the Q Base Administration Portal 22 4 6 Factory reset of Q Base 27 4 7 Insert remove the micro...

Страница 3: ...e User Manual 03 2019 3 8 3 Certificates 34 8 4 Waste Electrical and Electronic Equipment WEEE 34 8 5 FCC Declaration 34 9 Appendix B Ordering Information 35 Ordering Information 35 10 Revision Histor...

Страница 4: ...teway and the QIAcube Connect tablet application The gateway can be connected to one or more QIAcube Connect instruments and serves as an interface between the instrument and the QIAcube Connect table...

Страница 5: ...ll one of the QIAGEN Technical Service Departments or local distributors see back cover or visit www qiagen com 1 1 2 Policy statement It is the policy of QIAGEN to improve products as new techniques...

Страница 6: ...and servicing of the QIAcube Connect Task Personnel Training and experience Delivery No special requirements No special requirements Installation routine use and maintenance Laboratory technicians or...

Страница 7: ...gateways reliagate 10 12 3 General Description The Q Base hardware enables connection of the QIAcube Connect App running on a tablet to QIAcube Connect instruments via a local intranet connection The...

Страница 8: ...gure Q Base from a personal computer Important Do not connect to your LAN 7 Green LED indicator for Bluetooth on off first LED USER1 LED 8 Blue LED indicator for power on off last LED POWER 3 Two USB...

Страница 9: ...ation site Mains supply voltage fluctuations are not to exceed 10 of nominal supply voltages Important The power connector is NOT protected against short circuit Always include an external fuse to pro...

Страница 10: ...the application 6 On the tablet press the Configuration icon to start Bluetooth scanning for Q Base devices Note For successful Bluetooth communication between Q Base and tablet the devices must be wi...

Страница 11: ...e password guidelines described by the information box on the screen and then press Reset 11 Enter the LAN or Wi Fi settings as described in sections 4 3 1 1 or 4 3 1 2 before proceeding with step 12...

Страница 12: ...n the QIAcube Connect instrument and log in as an admin user 13 On the QIAcube Connect touchscreen select the Configuration tab and then select the Q Base tab as shown below 14 Make sure that the box...

Страница 13: ...he QIAcube Connect touchscreen press Apply to continue 17 Press Finish Configuration on the tablet Important If you don t press Finish Configuration the connection will only be established after 10 mi...

Страница 14: ...ss the WLAN tab in the QIAcube Connect App to configure the Wi Fi connection 2 Select the desired Wi Fi network from the list of Available networks 3 Once selected enter the Wi Fi password in the Pass...

Страница 15: ...professional Note When entering details into the screen above Static IP Manual is selected by default 1 In the IP address field in the QIAcube Connect App enter the IP address that should be used for...

Страница 16: ...ensure the connection to your QIAcube Connect instrument without using Bluetooth Note If you intend to connect Q Base to your LAN and your LAN does not support automatic assignment of IP addresses not...

Страница 17: ...rectly display all features of the Q Base Administration Portal Note Q Base uses a self signed certificate for the https connection Therefore the browser may issue a security warning Ignore the warnin...

Страница 18: ...nu on the left hand side Note You will not be able to change any other Q Base settings while you are connected via ETH0 port To access other settings finish the network setup and then access the Q Bas...

Страница 19: ...bled is checked 12 Enter the Q Base IP address in the Q Base URL field on the QIAcube Connect touchscreen marked in red in the screenshot below Note The IP address shown above is just an example 13 On...

Страница 20: ...able Wi Fi networks 3 Select the desired Wi Fi network from the list of Available networks 4 Once selected enter the Wi Fi password in the Password field Note The server SSID and security type details...

Страница 21: ...the Gateway field enter the IP address of the gateway 5 Press Connect 6 Proceed with step 10 in Section 4 3 2 page 18 LAN connection using DHCP 1 To use DHCP configured LAN select DHCP in the network...

Страница 22: ...n can be performed though the Q Base Administration Portal via a secure https connection using an internet browser on a personal computer that is connected to the local network Note It is not possible...

Страница 23: ...3 Enter the login id and the password that was set during initial Q Base set up Section 4 3 4 You can now access the Maintenance features System Time Settings and Instrument Administration via the si...

Страница 24: ...manually unplug the power cord for a few seconds We suggest not to use the Reboot button when the Wi Fi Bluetooth dongle is used 4 5 4 Update Q Base software New versions of software for Q Base can b...

Страница 25: ...r more information on Run Report storage on the instrument please refer to the QIAcube Connect instrument user manual 1 Select Maintenance from the sidebar 2 Current max number of run reports will be...

Страница 26: ...d to the Q Base it can be disabled in the Instrument Administration function 1 Select Instrument Administration from the sidebar of the Q Base Administration Portal 2 A list of instruments connected t...

Страница 27: ...point 7 in Section 3 1 page 8 will blink during the factory reset and will turn off when the factory reset is complete Note If you are using the Wi Fi Bluetooth dongle the Q Base may not be able to us...

Страница 28: ...igured the app home screen will show an overview of instrument status for each instrument Three possible instrument statuses can be displayed Offline the QIAcube Connect instrument is not connected to...

Страница 29: ...etup allows preparation of an instrument run using the QIAcube Connect App on the tablet instead of the QIAcube Connect touchscreen All run setup information will be displayed in the app in the same w...

Страница 30: ...bar code using the 2 D bar code reader of the QIAcube Connect instrument 5 3 Maintenance The Maintenance screen shows the current maintenance status information of the selected instrument 5 4 History...

Страница 31: ...ooth is enabled on the tablet and that the installation procedure is started from the QIAcube Connect App within 10 minutes by pressing the Configuration icon If Q Base still cannot be found refresh t...

Страница 32: ...10 minutes and retry 6 3 1 6 How can I retrieve a forgotten password If the password is lost it can be reset by performing a factory reset of Q Base see Section 4 6 Factory reset of Q Base 6 3 1 7 Ca...

Страница 33: ...ss will be assigned to Q Base LAN Local area network a wired connection between one or more devices to a particular network SSID Service set identifier this is the Wi Fi network s unique name and is t...

Страница 34: ...equested from QIAGEN Technical Services 8 3 Certificates For certificates refer to the ReliaGATE 10 12 user manual from Eurotech https www eurotech com en products iot multi service iot edge gateways...

Страница 35: ...D SDHC 9026169 For up to date licensing information and product specific disclaimers see the respective QIAGEN kit handbook or user manual QIAGEN kit handbooks and user manuals are available at www qi...

Страница 36: ...Q Base User Manual 03 2019 36 This page intentionally left blank...

Страница 37: ...Q Base User Manual 03 2019 37 This page intentionally left blank...

Страница 38: ...Q Base User Manual 03 2019 38 This page intentionally left blank...

Страница 39: ...ooth SIG Inc Chrome Google LLC Internet Explorer Microsoft Corporation Mozilla The Mozilla Foundation Registered names trademarks etc used in this document even when not specifically marked as such ar...

Страница 40: ...Q Base User Manual 03 2019 40 1117167 03 2019 HB 2620 002 www qiagen com Technical Support www support qiagen com...

Отзывы: