Quality in Electronic Manufacturing
Pag. 22 di 27
HB 237.16
Description
Keyboard
Display
The request is made to introduce the delta for activating the third
output enabled in set-up (min. 0 - max. 9999).
The operator can introduce its value and confirm with
ENTER
.
When confirmed with
ENTER
the programming of the other enabled
outputs will appear. After programming, the display returns to the
one currently in use.
I
3 d 1 2 3
= OFF
SET
MINIMUM TIMES OF ACQUISITION
Description
Access to calibration of acquisition times.
Introduce access code "732" and confirm with
ENTER
.
The display shows the acquisition time for input I2. Every check
introduces a delay time of 5 milliseconds. When a value of zero is
set, the input acquires 10 checks (acquisition time 50 milliseconds).
The operator can introduce a new value (min. 0 - max. 99) and
confirm with
ENTER
. The display returns to the one currently in use.
Keyboard
Display
H
0 0 0
+
n
u 2
9 9
× 1 sec.
CHOICE OF THE PROGRAM TO BE EXECUTED
Description
Keyboard
Display
× 2 sec.
P r o G I
Access to the choice of program.
Enter the number of the required program and confirm with
ENTER