Quality in Electronic Manufacturing
Pag. 21 di 27
HB 237.16
INTRODUCING MORE THAN ONE WORK PROGRAM (SET-UP "
nP
" > DI "1")
Description
Keyboard
Display
+
× 2 sec.
P
r
n
r
1
= ON
A
b U I 0
I
I 1 2 3 4
A
b U 2 0
I
2 2 3 4 5
Access to introduction of work programs.
A request is made to introduce the program in which to enter the the
new work quotas (max. 9).
The operator can introduce the required program and confirm with
ENTER
.
The request is made to enable or disable output U1.
0
= Output disabled.
1
= Output enabled.
The operator can decide whether to enable or disable the output
and confirm with
ENTER
.
Example with set-up parameter "
FU1
" set on "1".
The (flashing) quota 1 currently in use is displayed.
The operator can introduce the quota relative to the first output
enabled (min. -9999 - max. 9999) and confirm with
ENTER
.
The request is made to enable or disable output U2.
0
= Output disabled.
1
= Output enabled.
The operator can decide whether to enable or disable the output
and confirm with
ENTER
.
Example with set-up parameter "
FU2
" set on "2".
The (flashing) quota 2 currently in use is displayed.
The operator can introduce the quota relative to the second output
enabled in set-up (min. -9999 - max. 9999) and confirm with
ENTER
.
The request is made to introduce the activation time for the second
output enabled (max. 99.99 seconds).
The operator can introduce its value and confirm with
ENTER
.
Example with set-up parameter "
FU3
" set on "3" when the
parameter "
Ab
" is set on "1".
The request is made to enable or disable output U3.
0
= Output disabled.
1
= Output enabled.
The operator can decide whether to enable or disable the output
and confirm with
ENTER
.
The (flashing) quota 3 currently in use is displayed.
The operator can introduce the quota relative to the third output
enabled in set-up (min. -9999 - max. 9999) and confirm with
ENTER
.
Follows on next page.
I
2 t 1
0
0 0
A
b U 3 0
I
3 3 4 5 6
SET