Quality in Electronic Manufacturing
Pag. 16 di 27
HB 237.16
FUNCTION
DISPLAY
DESCRIPTION
0
= Output disabled.
1
= The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 2).
The count increases (UP).
2
=The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 2) and
remains enabled for the time set in the work program (timer 2).
The count increases (UP).
3
=The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 2) and
remains enbled for the delta set in the work program (delta 2).
The count increases (UP).
4
= The output is activated when the count is equal to or less than
the value introduced in the work program (quota 2).
The count decreases (DOWN).
5
= The output is activated when the count is equal to or less than
the value introduced in the work program (quota 2) and
remains enabled for the time set in the work program (timer 2).
The count decreases (DOWN).
6
= The output is activated when the count is equal to or less than
the value introduced in the work program (quota 2) and
remains enabled for the delta set in the work program (delta
2).
The count decreases (DOWN).
F
U 2
0
Choice of functions
for output U2