FUNCTION
DISPLAY
DESCRIPTION
This is the value loaded on the count when input I1 is activated or
the
CLEAR
key is pressed when the parameter "
FC
" is set on "2".
Q
I 1 2 3 4
Determines the number of programs to be used.
n
P
0
0
= Introduction of work programs without the access code.
1
= Introduction of work programs with the access code (password
532).
Introduction of
work programs
E
P
0
0
= Output disabled.
1
= The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 1).
The count increases (UP).
2
= The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 1) and
remains enabled for the time set in the work program (timer 1).
The count increases (UP).
3
= The output is activated when the count is equal to or greater
than the value introduced in the work program (quota 1) and
remains enabled for the delta set in the work program (delta
1).
The count increases (UP).
4
=The output is activated when the count is equal to or less than
the value introduced in the work program (quota 1).
The count decreases (DOWN).
5
= The output is activated when the count is equal to or less than
the value introduced in the work program (quota 1) and
remains enabled for the time set in the work program (timer 1).
The count decreases (DOWN).
6
=The output is activated when the count is equal to or less than
the value introduced in the work program (quota 1) and
remains enabled for the delta set in the work program (delta
1).
The count decreases (DOWN).
F
U I
0
Choice of functions
for output U1
Preset Quota
Min. -99999
Max. 99999
Number of
programs
Max. 9