Quality in Electronic Manufacturing
Pag. 13 di 27
HB 237.16
3 - 1 SET-UP
As these parameters set the operating mode of the instrument, access is restricted to the installer only; a password
must be entered for access to programming as follows:
Description
Access the set-up programming.
Enter the access code "237" and confirm with
ENTER
.
Keyboard
Display
H
0 0 0
+
= ON
FUNCTION
DISPLAY
DESCRIPTION
0
=The instrument is not provided with Input/Output expansion.
1
=Input/Output expansion is installed on the instrument.
Expansion
enabling
A
E
0
0
=Normal display.
1
=Display with HDR 1 system (High definition reading).
2
=Display with HDR 2 system (High definition reading).
N.B.
Refer to the "Installation, maintenance and servicing"
manual.
H
d
0
Display method
Specifies the number of figures after the decimal point, with which
to display the count (axis position).
N.B.
Introduction of decimal figures influences the DISPLAY of
the count; precision in positioning depends on the number
of impulses supplied by the transducer.
C
d
0
Decimal figures
Max. 3
This parameter indicates by how much the encoder revolution
impulses must be multiplied to display the lengths in the required
unit of measurement. Values can be introduced from 0.00200 to
4.00000 bearing in mind that the frequency of the F1 phases must
not exceed the instruments maximum count frequency.
N.B.
Refer to the "Installation, maintenance and servicing
manual".
Encoder resolution
E
4
0 0 0 0 0
0
=Not enabled.
1
=Resets count to zero.
2
=Loads the count in impulse mode with the preset quota.
C
L
0
Functions of the
CLEAR
key
× 1 sec.
PRG