Quality in Electronic Manufacturing
Pag. 10 di 27
HB 237.16
COUNT INPUTS
Name
F1
N / P
P1
"Phase 1" input incremental transducer.
F1
N / P
P1
"Phase 2" input incremental transducer.
For details of the count inputs, refer to the chapter entitled "Electrical characteristic" in the "Hardware
structure" booklet enclosed with this manual.
Polarizer
Operating logic
Description
Key
N = Transducer with NPN logic.
P = Transducer with PNP logic.
2 - 3 OUTPUTS
Output Characteristics
Refer to the chapter entitled "Electrical Characteristics" in the "Hardware structure" booklet enclosed with this manual.
Name
U1
P
C1
C
Quota 1.
With set-up parameter "
LI
" set on "0", the output is activated when the count reaches the value of
the quota set as parameter "
I
" in the work program. When the set-up parameter "
LI
" is set on "1", the output
is de-activated when the count reaches the value of the quota set as parameter "
I
" in the work program.
U2
P
C1
C
Quota 2.
§With set-up parameter "
L2
" is set on "0", the output is activated when the count reaches the value
of the quota set as parameter "
2
" in the work program. When the set-up parameter "
L2
" is set on "1", the output
is de-activated when the count reaches the value of the quota set as parameter "
2
" in the work program.
Operating logic
Polarizer
Activation mode
Description
Key
C = Continuous signal.
P = Programmable in set-up.