Module Selection

For detailed key electrical data, please refer to the 
product data sheet for the respective product. 

 

Ä

only connect modules of the same type and the same 
power class.

Safety factor

During normal operation, a module may generate a greater 
current and / or higher voltage than that determined under 
standardised test conditions. 

Refer to As / NZs 5033:2012 (including all relevant 
amendments) and the clean energy council Guidelines 
(for Australia).

Series Connection

connection of modules in series is only permitted up to 
the maximum system voltage as listed in the applicable 
data sheet.  

 

Ä

take into account all possible operating situations and all 
relevant technical norms and regulations when designing 
the system. this will ensure that the maximum system 
voltage, including all necessary safety margins, is not 
exceeded. 

 

Ä

take the voltage limit of the inverter into account when 
determining the maximum number of modules in the 
string.  

Parallel Connection

modules may be damaged by the occurrence of reverse 
currents (caused by module defects, ground leaks, or 
defective insulation).

 

Ä

ensure that the maximum reverse current load capacity 
indicated in the data sheet is observed. 

in order to limit reverse currents that may occur, we 
recommend using the following safety options:

1)  Layout with a limited number of parallel connected 

strings :

Refer to As / NZs 5033:2012 (including all relevant 
amendments) for parallel string overcurrent protection 
requirements.

2)  Layout with string fuses :

place fuses for each string of modules at the plus and 
minus ends. observe the maximum permitted number 

of strings as indicated in the specifications provided by 

the respective string fuse manufacturer and the technical 
guidelines.

NOTE! 

When installing different product versions, the lowest 
minimum permitted reverse current load capacity applies.  

Inverters

inverters with or without transformers may be used.

2.4  electrical layout

2 PLaNNING

2 PLaNNING

2.3  Mounting options

SPeCIfICaTIoN of THe CLaMPING raNGe

 

Ä

in case of varying clamping range for push and pull loads the smaller clamping range must be applied.

DISTaNCe BeTWeeN MoDULeS

 

Ä

maintain an interval of at least 10 mm between two modules.

MoUNTING oPTIoN CL1

 

Ä

ensure, that the subconstruction does not run below the junction box.

MoUNTING oPTIoN CL4

 

Ä

ensure, that the subconstruction runs exactly below the frame, not below the laminate (module less frame).

MoUNTING oPTIoNS fB1 aND fB2

• 

the fastening points are located on the backside of the module frame.

Содержание Q.Peak-G3

Страница 1: ...Valid for Australia and New Zealand Q Pro G3 Q PRO BLK G3 Q Peak G3 Q PLUS G3 Installation and Operation Manual ...

Страница 2: ...procedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations The solar module operator is responsible for compliance with all applicable statutory requirements and regulations Ä Ä The following regulations and standards must be upheld at all times during the i...

Страница 3: ... for the functionality and safety of the modules Ä Ä Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry out a structural analysis for the entire project Ä Ä If your questions are not satisfactorily answered in the manual please contact your system supplier Additional information can be found on our websi...

Страница 4: ...ened to the ground the roof or the façade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Has electrochemical series that prevent corrosion among different metals Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by v...

Страница 5: ...ounting options Specifications Module type Mounting option Clamping range1 Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PRO G3 Q PRO BLK G3 Q PEAK G3 Q PLUS G3 CL1 Push 245 345 346 445 3500 2400 5400 Pull 245 345 346 445 5650 4000 CL3 Push 245 445 5700 Pull 245 345 346 445 4000 4000 CL4 Push 0 300 2000 Pull 0 300 2000 FB1 Push 3500 Pull 3100 FB2 Push 4000 Pull 3100 IP1 Push 3700 Pull 37...

Страница 6: ...ground leaks or defective insulation Ä Ä Ensure that the maximum reverse current load capacity indicated in the data sheet is observed In order to limit reverse currents that may occur we recommend using the following safety options 1 Layout with a limited number of parallel connected strings Refer to AS NZS 5033 2012 including all relevant amendments for parallel string overcurrent protection req...

Страница 7: ... packaging until installation Ä Ä Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your dealer of any damages immediately 3 1 Safety and transport 3 Installation Note Module damage may occur Ä Ä Never lift or move the module with the connection cables or junction box Ä ...

Страница 8: ... in windy or wet weather Danger Risk of fatal injury due to electric shock Ä Ä Only use dry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not drill any other holes 3 2 Preparation of installation 3 Installation Ä Ä Maintain an interval of at least 10 mm between two modules 10mm 1 0 m m Option 2 Ä Ä Install the module at the 4 mount...

Страница 9: ...e wiring with extreme caution Ä Ä Ensure that the modules are disconnected at the inverter prior to separation Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge Danger Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Do not remove bypass diodes Danger Risk of fatal injury due to electric...

Страница 10: ...c shock Ä Ä Ensure that all electrical components are in a proper dry and safe condition A module with 1 160 mm long cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cable Standard wiring with a return cable Inverter Inverter 1 2 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functional tests have been carried out accor...

Страница 11: ...e Maintenance Ä Ä The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all electrical components are clean and undamaged Cleaning WARNING Risk of injury due to hot and live modules Ä Ä Only clean modules that have cooled down Ä Ä Do not carry or wear any electrically conductive parts WA...

Страница 12: ...4 20 Berry Street North Sydney NSW 2060 Australia TEL 61 0 29016 3033 FAX 61 0 269016 3032 EMAIL q cells australia q cells com WEB www q cells com au Subject to change without notice Hanwha Q CELLS GmbH Installation manual G3 modules_2015 02_Rev06_AU ...

Отзывы: