12 – PC connection
12.1 – USB data download
The files contained in the memory are managed like any files in a digital archive memory (USB stick, memory card, etc,); this is why there is no
download time, you simply need to connect the Start Plus device to the PC and copy the files contained in the SESSION folder.
The *.SES file is formatted as follows:
NAME DATE TIME CIRCUIT BEST-LAP IDEAL-TIME.SES
Do not rename the session files under any circumstances; Start will no longer be able to open the files.
To eliminate the content of the memory, eliminate all the files inside the SESSION folder.
12.2 – Wi-Fi
The new Start Plus is equipped with an integrated Wi-Fi module that will be used for
data download and settings related to storage. Wi-Fi turns on when the product is turned
on and turns off when the motorcycle exceeds 30Km/h, to reactivate the Wi-Fi it will be
necessary to turn off and on the GPS receiver.
N.B: the Wi-Fi module is active only on the main screen and when the
product is charging, it is deactivated when you browse the menu.
After connection between RacePro and Start Plus, all the sessions stored in memory will
be displayed, select a session and click the “Download Session” button to start the data
download or the “Delete Session” button to delete the session.
The default data for the Wi-Fi network are the following:
Network name: PZRacing ST400P-USER 1
Password: 12345678
From the software, in the Network tab, it is possible,
and recommended
, to change the last part of the network name (USER 1) and the password.
Once modified it will be necessary to close the RacePro program, turn off and on the dashboard.
13 – Accelerometer
Start Plus is equipped with an internal accelerometer that is used for detecting the start and to
store the values on the recorded file.
We remind you that in order to have a correct reading of the values of the internal accelerometer it
is necessary to install the Start Plus integral with the vehicle frame, therefore the data stored by
installing the lap timer on the steering wheel or on the fork plate will not be truthful.
On the side the orientation of the accelerometer axes.
14 – Self-diagnosis
Start Plus has a self-diagnosis function that allows you to verify all the features of the product. To
perform the diagnosis, access the Menu, press the INFO icon, then press the TEST icon; once
diagnosis has started, the product will verify all the internal components and signal OK in the
event of a positive outcome and ERROR in the event of a negative outcome.
15 – Firmware installed and date of first use
It is possible to check both, the date of the first use of the product and the version of the firmware installed at start-up.
By holding down the power button, after the initial logo has been created, the version of the firmware installed will be displayed at the bottom right of
the display and, at the bottom left, the date of first use (date on which the first session has been created).
16 – Replace the startup image
It is possible to change the startup image by inserting an image in the IMAGE folder. The image must have the following characteristics:
Format: Bitmap (.bmp)
Dimensions: 240x128px
Color: monochrome
Any image with different characteristics will be discarded and the default one will be used.
PZRacing Via de Gasperi 5 – 61032 Fano (PU) Italy - Tel: +39 0721 820434 – Email: [email protected]