ST-730 Series Inline Turbidity Probes
User Manual
February
23,
2020
Rev.
1.31
©
2017
Pyxis
Lab,
Inc.
Lab
Proprietary
and
Confidential
Страница 1: ...ST 730 Series Inline Turbidity Probes User Manual February 23 2020 Rev 1 31 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confidential...
Страница 2: ...6 5 2 Connecting to uPyxis Mobile App 6 5 3 Calibration Screen and Reading 7 5 4 Diagnosis Screen 8 5 5 Device Info Screen 8 6 Setup and Calibration with uPyxis Desktop App 9 6 1 Install uPyxis Deskt...
Страница 3: ...ovided shall conform to the reasonable standards of technical com petency and performance effective at the time of delivery All service interventions are to be reviewed and authorized as correct and c...
Страница 4: ...Resolution NTU 0 1 1 0 1 0 05 10 Accuracy 2 of reading Method Nephelometric with white LED and IR LED 860 nm light sources Calibration Two point calibration against standard solution Outputs 4 20mA A...
Страница 5: ...Tee O ring and Nut P N ST 001 7 Pin Female Adapter Flying Leads Cable 2 ft P N MA 1100 User Manual available online at www chemtrol com au probes selection inline turbidity meter series 3 2 Optional...
Страница 6: ...o the O ring groove on the tee 2 Insert the ST 730 series probe into the tee 3 Tighten the tee nut onto the tee to form a water tight compression seal NOTE It is recommended to install the ST 730 seri...
Страница 7: ...ow to connect the ST 730 series probe to a controller Wire Color Designation Red 24V Black 24V Power ground White 4 20mA Green 4 20mA Blue RS 485 A Yellow RS 485 B Clear Shield earth ground Internally...
Страница 8: ...Store or Google Play Figure 6 5 2 Connecting to uPyxis Mobile App Turn on Bluetooth on your mobile phone Do not pair the phone Bluetooth to the ST 730 series probe Open uPyxis Mobile App Once the app...
Страница 9: ...s Mobile App will default to the Calibration screen From the Calibration screen you can perform calibrations by pressing on Zero Calibration Slope Calibration and 4 20mA Span Follow the screen instruc...
Страница 10: ...From the Diagnosis screen you can check the diagnosis condition as well as Export Upload Figure 9 5 5 Device Info Screen From the Device Info screen You can name the Device or Product Figure 10 ST 730...
Страница 11: ...r for the USB Bluetooth adapter MA NEB the USB RS485 adapter MA 485 and the main uPyxis Desktop application Double click the uPyxis Setup exe file to install Figure 11 Click Install to start the insta...
Страница 12: ...you can set the information description for Device Name and Product Name then click Set to save Figure 13 6 4 Calibration Screen To calibrate the device click on Calibration On the Calibration screen...
Страница 13: ...n Then follow the instruction on how to calibrate then click Slope Calibration Figure 16 6 4 3 4 20mA Span To perform 4 20mA Span click on 4 20mA Span Then follow the instructions provided to alter th...
Страница 14: ...in the Diagnosis screen you can view the Diagnosis Condition of the device Figure 18 7 Communication using Modbus RTU The ST 730 series probe is configured as a Modbus slave d evice In addition to the...
Страница 15: ...tential foulants and con taminants Our inline probe cleaning solutions below have been shown to remove most common foulants and contaminants A small soft bristle brush Q Tips cotton swab or soft cloth...
Страница 16: ...d earth ground wire to a conductor that contacts the sample water electrically such as a brass pipe adjacent to the ST 730 series tee Carry out routine calibration verification against a qualified tur...