Confidentiality

 

The information contained in this manual may be confidential and proprietary and is 
the property of Pyxis Lab Inc. Information disclosed herein shall not be used to 
manufacture, construct, or otherwise reproduce the goods disclosed herein. The 
information disclosed herein shall not be disclosed to others or made public in any 
manner without the express written consent of Pyxis Lab Inc. 

Standard Limited Warranty 

Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab 
will, at its option, repair or replace instrument components that prove to be defective 
with new or remanufactured components (i.e., equivalent to new). The warranty set 
forth is exclusive and no other warranty, whether written or oral, is expressed or 
implied. 

 
Warranty Term 

The Pyxis warranty term is thirteen (13) months ex-works. In no event shall the 
standard limited warranty coverage extend beyond thirteen (13) months from original 
shipment date. 

 
Warranty Service 

Damaged or dysfunctional instruments may be returned to Pyxis for repair or 
replacement. In some instances, replacement instruments may be available for short 
duration loan or lease. 
 
Pyxis warrants that any labor services provided shall conform to the reasonable 
standards of technical competency and performance effective at the time of delivery. 
All service interventions are to be reviewed and authorized as correct and complete at 
the completion of the service by a customer representative, or designate. Pyxis 
warrants these services for 30 days after the authorization and will correct any 
qualifying deficiency in labor provided that the labor service deficiency is exactly 
related to the originating event. No other remedy, other than the provision of labor 
services, may be applicable. 
 
Repair components (parts and materials), but not consumables, provided in the 
course of a repair, or purchased individually, are warranted for 90 days ex-works for 
materials and workmanship. In no event will the incorporation of a warranted repair 
component into an instrument extend the whole instrument’s warranty beyond its 
original term. 
 

Shipping 

A Repair Authorization Number (RA) must be obtained from the Technical Support 
([email protected]) before any product can be returned to the factory. Pyxis will 
pay freight charges to ship replacement or repaired products to the customer. The 
customer shall pay freight charges for returning products to Pyxis. Any product 
returned to the factory without an RA number will be returned to the customer.

 

 

Содержание EM-400

Страница 1: ...Rev 1 0 Firmware version 1 10...

Страница 2: ...2 Pyxis Lab Inc 120 Jeffrey Ave Holliston MA 0176 USA www pyxis lab com service pyxis lab com...

Страница 3: ...ies 2 1 5 Optional Accessories 2 1 6 Light Shield Cover 2 2 Start Pyxis EM 400 3 2 1 Battery Installation 3 2 2 Description of the Control Keys 4 2 3 Turning On Off Pyxis EM 400 4 3 CHLOROPHYLL A Meas...

Страница 4: ...e Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical competency and performance effective at the time of delivery All service interventions are to b...

Страница 5: ...irement 1 2 Pyxis EM 400 Major Features The Pyxis EM 400 analyzer measures the in vivo chlorophyll a concentration in live algae cells Chlorophyll a is the main photosynthetic pigments of algae Chloro...

Страница 6: ...Customer Service at service pyxis lab com 1 4 Standard Accessories Quick instruction guide 9V alkaline battery Full instrument manual is available from www pyxis lab com 1 5 Optional Accessories Carry...

Страница 7: ...r new battery installation The EM 400 battery compartment shown in Figure 2 is on the back side of the instrument Install battery as follows 1 Remove the battery compartment cover by loosening two scr...

Страница 8: ...on associated with the keys and can change according to the screen modes Figure 3 Keys and associated functions 2 3 Turning On Off Pyxis EM 400 To turn on the EM 400 press OK momentarily and release T...

Страница 9: ...ample containing 100 ppb CHLOROPHYLL A the measured CHLOROPHYLL A should be stabilized within the range of 98 to 102 ppb The EM 400 does not need to be turned off between measurements of two samples R...

Страница 10: ...lgae Instead the standard contains a fluorophore that emits a 675 nm fluorescence when it is excited by a 470 nm light This calibration ensures that any change in fluorescent signal strength caused by...

Страница 11: ...also update to show the Slope steps as in Figure 6 The Cycle command replaces Zero on the black bar and the possible chlorophyll a selection is displayed in red The default is 100 ppb If the displaye...

Страница 12: ...Calibration Succeed will appear as in figure 7 Figure 7 11 Press the Exit labeled key OK to return to the basic read screen The screen will be similar to Figure 4 Slight variance in the chlorophyll a...

Страница 13: ...s screen where raw measurement data are displayed Figure 9 The information has no use for normal operation Please provide an image of both the device information screen and the diagnosis screen when y...

Страница 14: ...or Bluetooth for upgrading the device software The EM 400 can be wirelessly paired with other Pyxis devices for exchanging data In the normal operation modes the wireless function is turned off If yo...