background image

5.3

Calibration Screen and Reading

When connected, the

uPyxis®

Mobile App will default to the

Calibration

screen. From the

Calibration

screen, you can perform calibrations by pressing on

Zero Calibration

,

Slope Calibration

, and

4–20mA Span

.

Follow the screen instructions for each calibration step.

Figure 8.

ST-590 User Manual

[email protected]

| +1 (866) 203-8397

10

Содержание 50690

Страница 1: ......

Страница 2: ...luorescent Polymer Inline Sensor User Manual January 29 2021 Rev 3 01 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confi...

Страница 3: ...Connecting to uPyxis Mobile App 9 5 3 Calibration Screen and Reading 10 5 4 Diagnosis Screen 11 5 5 Device Info Screen 11 6 Setup and Calibration with uPyxis Desktop App 12 6 1 Install uPyxis Desktop...

Страница 4: ...elivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services fo...

Страница 5: ...te interference commonly associated with real world waters The Pyxis ST 590 sensor has a short fluidic channel and can be easily cleaned The fluidic and optical ar rangement of the ST 590 sensor is de...

Страница 6: ...40 F 7 60 C Pressure Up to 100 psi 0 7 MPa Up to 290 psi 2 0 MPa Enclosure Rating IP67 Regulation CE With Pyxis s continuous improvement policy these specifications are subject to change without notic...

Страница 7: ...ssories The following optional accessories can be ordered from Pyxis Customer Service order pyxis lab com or Pyxis E Store at https pyxis lab com shop Figure 1 ST 590 User Manual service pyxis lab com...

Страница 8: ...tall the ST 590 sensor into the ST 001 Tee Assembly follow the steps below 1 Insert the provided O ring into the O ring groove on the tee 2 Insert the ST 590 sensor into the tee 3 Tighten the tee nut...

Страница 9: ...T to 1 4 tubing adapters are used to connect the sensor to the sampling system Sample water entering the sensor must be cooled down to below 104 F 40 C The sensor can be held by a 1 75 inch pipe clamp...

Страница 10: ...ower ground and the negative 4 20mA ter minal on the ST 590 sensor are internally connected Follow the wiring table below to connect the ST 590 sensor to a controller Table 2 Wire Color Designation Re...

Страница 11: ...adapters may result in permanent damage of the ST 590 sensor communication hardware Figure 5 USB connection to ST 590 sensor 5 Setup and Calibration with uPyxis Mobile App 5 1 Download uPyxis Mobile...

Страница 12: ...g steps 1 Open uPyxis Mobile App 2 On uPyxis Mobile App pull down to refresh the list of available Pyxis devices 3 If the connection is successful the ST 590 and its Serial Number SN will be displayed...

Страница 13: ...fault to the Calibration screen From the Calibration screen you can perform calibrations by pressing on Zero Calibration Slope Calibration and 4 20mA Span Follow the screen instructions for each calib...

Страница 14: ...rt Upload This feature may be used for technical support when communicating with service pyxis lab com Figure 9 5 5 Device Info Screen From the Device Info screen You can name the Device or Product as...

Страница 15: ...k 4 5 if not previously installed on the PC the USB driver for the USB Bluetooth adapter MA NEB the USB RS485 adapter MA 485 and the main uPyxis Desktop application Double click the uPyxis Setup exe f...

Страница 16: ...computer 2 Launch uPyxis Desktop App 3 On uPyxis Desktop App click Device Connect via USB Bluetooth or Connect via USB RS485 Fig ure 12 4 If the connection is successful the ST 590 and its Serial Numb...

Страница 17: ...tion description for Device Name Product Name and Modbus Address then click Set to save Figure 13 6 4 Calibration Screen To calibrate the device click on Calibration On the Calibration screen there ar...

Страница 18: ...is screen you can view the Diagnosis Condition of the device This feature may be used for technical support when communicating with service pyxis lab com Figure 15 7 Outputs 7 1 4 20mA Output Setup Th...

Страница 19: ...s Desktop App click 4 20mA Span found on the Calibration Screen shown in Figure 17 Figure 16 Figure 17 7 3 Communication using Modbus RTU The ST 590 sensor is configured as a Modbus slave device In ad...

Страница 20: ...pected and cleaned if required It is suggested that the ST 590 sensor be checked for fouling and cleaned calibrated on a monthly basis Heavily contam inated waters may require more frequent cleanings...

Страница 21: ...90 sensor from direct sunlight and precipitation 9 Troubleshooting If the ST 590 sensor output signal is not stable and fluctuates significantly make an additional ground con nection connect the clear...

Отзывы: