background image

KX15DQ

15m Digital PIR Detector

 

0845 6434 999 (UK). +44(0)1709 535 225

  

 [email protected]   

 

www.pyronix.com   

Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK  

 

       

RINS1039-7

EN50131-2-2:2008              

EN50131-1:2006+A1:2009        

PD6662:2010

Security Grade 2

Environmental Class II

E N G L I S H

(Diagram references)

Technical Specification

Warranty

Product Warning Information

This product is sold subject to our standard warranty conditions and is warranted 

against defects in workmanship for a period of five years.
For further warranty information visit: 

www.pyronix.com/warranty

For electrical products sold within the European Community. At the end of the 

electrical products life, it should not be disposed of with household waste. Please 

recycle where facilities exist. Check with your Local Authority or retailer for recycling 

advice in your country.  The declaration of conformity may be consulted at 

www.pyronix.com/product-compliance.php

This product is approved for use in the Residential, 

Commercial and Light Industrial Environments.

EOL

The KX15DD Printed Circuit Board

® 

D

C3

AUTO  HI

LOW AUTO

AUTO  HI

LOW AUTO

AUTO  HI

LOW AUTO

=

=

=

=

LOW

Model:  

KX15DQ

Colour:  

White

LED Colour:  

Blue

Casing:  

3mm ABS, 0.4mm HDPE in lens area

Detection Method:  

Digital Quad Signal Processing

PIR Sensitivity:  

Auto (Default), High, Low

Temperature Compensation:  

Digital

Detection Range:  

15m  (13m by EN50131-2-2 & INCERT criteria)

Detection Speed:  

0.3 - 3.0 m/s

Operating Voltage:  

9 - 16V DC 13.8V DC typical

Current Consumption:  

13mA @ 12V (Min),  16mA @12V (Max)

Relay Output:  

50mA 60V DC, 42 VAC (RMS)

Contact Resistance:  

< 10 ohms

Mounting Height:  

1.8 - 2.4m

Tamper Switch:  

12V  50mA

Storage Temperature:  

-40

o

C to  80

o

C

Certified Operating Temperature:  

-10

o

C to  40

o

C

Nominal Working Temperature:  

-30

o

C to  70

o

C

Accessories:  

Wall and Ceiling brackets

Emissions:  

EN55022 Class B

Immunity:  

EN50130-4

HIGH 

PCB

DEFAULT

PREDEFINITO

HIGH / 

LOW

 

B

START

f) Back 

Tamper

C

D

F

G

E

1

A

B

2

C

D

3

A

LED ON

LED OFF

LEDs

1

A

B

C

Printed Circuit Board (PCB)
LED light pipe / diffuser
Lens

D

E

F

G

Lens holder
PCB screw
Captive nut

Casing screw

2
33
34

PCB configuration (Including PIR sensitivity)

Mounting Options

The 15m Volumetric Lens.                        Dimensions and Weight

EOL Resistor Headers: 

The KX15DQ has 2 sets of header pins (as shown). These 

headers are used to select the End of Line resistance for EOL wiring applications.  

NOTE: If EOL wiring is not used, leave the headers OFF. 

Remote LED Enable: 

This is used when the LED is disabled via the  LED ON/OFF 

link. To enable this feature the LED terminal needs to be connected to an output 

on the control panel. When the system is in walk test mode the output should 

be at 0v. For Pyronix panels the output would usually be programmed as 

‘Remote LED enable’.

Powering Up: 

When the detector is first powered up, it will run through a self-test 

routine (indicated by the flashing blue LED). Once the LED goes out the detector 

is ready to use.

35

36

37

38

39

A

B

C

D

E

N/C

 - Normally Closed Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

PCX

 DEOL Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

EURO

 DEOL Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

Generic Control Panel (shows resistor locations)
2x Double End of Line Detectors to One Input 

(SEE CONTROL PANEL INSTRUCTIONS)

+

+

+

+

+

+

+

+

+

+

+

+

 P

IR

TAMPER

TAMPER

5K6, 4K7, 2K2, 1K

ALARM

6K8, 5K6, 

4K7, 2K2, 1K

A

B

B

C

3

AUTO

Отзывы: