background image

TS50131-2-4

EN50131-1

PD6662:2004

Security Grade 3

Environmental Class 2

TS50131-2-4

EN50131-1

PD6662:2004

Security Grade 2

Environmental Class 2

TS50131-2-2

EN50131-1

PD6662:2004

Security Grade 2

Environmental Class 2

3

2

2

KX10DTP

®

10m Dual Technology Pet 

Immune Digital Detector

RINS1601-2

1: Disassembling the KX 

4: Bracket Connections

6: Sensitivity Settings

7: AND/OR Mode

8: Microwave Potentiometer

5: Installation Hints

9: EOL Resistor Headers

a) Auto Sensitivity (Default)

b) Wall Bracket 

Fitting

a) Ceiling 

Bracket 

Fitting

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

a) Normally Closed

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

b) Single End of Line Wiring

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

KX

KX

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

ALARM CONTROL PANEL

+ -

ZONE1

CO

M

TA

MPER

TA

MPER

+ -

Link

+ -

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

KX

+ -

5K6

5K6

6K8

4K7

4K7 2K2 1K

1K

ALARM

TAMPER

TAMPER

ALM 

ALM 

2K2

Hard Wired

Resistor

c) Double End of Line Wiring

d) Two Double End of Line Detectors to One Input

e) Zone Doubling Example (For Matrix 424, 832, 832+)

14: Technical Specification

15: Compliance and Warranty

16: Contact Information

2: The Printed Circuit Board

3: Cable Entry + Mounting

10: Choose the Connection Type:

11: Powering Up

12: The 10m Volumetric Lens

13: Dimensions and Weight

b) Lens Illuminator

a) Printed Circuit Board

d) Lens Holder

c) Lens

f) Back 

Tamper

e) PCB 

Screw

f) Nut

g) Casing Screw

h) Microwave

Potentiometer

f) Tamper and Alarm 

Resistor Headers

a) Terminals

a) Mounting Screw 

Knockouts

b) Cable Entry 

Knockout

c) Case Lid Screw 

Fitting

b) Mains Frequency

c) Sensitivity Auto

See Section 6

d) AND/OR

 

e) ALARM LED

See section 7

50Hz 

(Default)

LED Disable

60Hz

LED Enable

(Default)

g) Piro Sensor

DO NOT TOUCH

The KX10DTP has 2 set of header pins at the top of 

the printed circuit board. These headers are used 

to select the End of Line resistance for EOL wiring 

applications. 

If EOL wiring is not used, leave the headers OFF. 

Note: turning pot fully anti-clockwise turns off 

microwave

Conventional Dual Tech (Both technologies need to 

be triggered simultaneously to generate an alarm)

AND

DO NOT USE OR MODE 

WITH THIS PET IMMUNE 

DETECTOR

The connection shows the 

example values 4k7 for alarm, 

4k7 for tamper (EOL). And 2K2 

for the zone doubling EOL.

The connection shows the 

example values 4k7 for alarm, 

4k7 for tamper (EOL). 

The 

connection 

shows the 

example  value   

4k7 for tamper 

(EOL). 

The 

connection 

shows the 

example 

values of 4k7 

for Alarm and 

4K7 for tamper 

(EOL). 

When the detector is first powered up, it will run 

through a self-test routine, indicated by the flashing 

LEDs. Once this has distinguished the detector is 

ready to use.

NOT READY

READY

Secure Holdings, Pyronix Ltd, 

Braithwell Way, Hellaby, 

Rotherham, South Yorkshire

 S66 8QY

For electrical products sold within the 

European Community. At the end of the 

electrical products useful life, it should 

not be disposed of with household 

waste. Please recycle where facilities 

exist. Check with your Local Authority 

or retailer for recycling advice in your 

country.

Customer Support: 

+44(0)845 6434 999 (local rate)

or +44(0)1709 535225 

Hours: Mon to Fri, 8:00am till 6:30pm

Email: [email protected]

Website: www.pyronix.com

Model

: KX10DTP

Colour

: White

LED Colours:

 Orange (Microwave), Blue (Alarm), 

Green (PIR)

Casing

: 3mm ABS, 0.4mm HDPE in Lens Area

Detection Method

: Low noise dual element 

pyroelectric sensor and Microwave Doppler Sensor

PIR Sensitivity

: Auto

Max Pet Tolerance: 

24kg (55 pounds)

Temperature Comp

: Digital

Detection Range

: 10m

Detection Speed

: 0.3 - 3.0m/s

Operating Voltage

: 9-16V DC 13.8V DC typical

This product is approved for use in 

the Residential, Commercial and Light 

Industrial Environment. It complies 

with EN50131-2-4:2008 at security 

grade 2, environmental class 2. UK = 

Suitable for use with systems installed 

to PD6662:2010. EXPORT = Suitable for 

use with systems installed to EN50131-

1:2006+A1:2009

WARRANTY: 

This product is sold subject to our 

standard warranty conditions and is warranted 

against defects in workmanship for a period of five 

years. In the interest of continuing improvements 

of quality, customer care and design, Pyronix ltd 

reserves the right to amend specifications without 

giving prior notice.

117 x 69 x 50mm

125g (4.4 oz) 

without bracket

Current Consumption

: 24mA @ 12V (Min), 30mA @ 

12V (Max)

Relay Output

: 50mA 60 VDC, 42 VAC (RMS)

Contact Resistance

: <10ohms

Mounting Height

: 2 - 2.4m

Tamper Switch

: 12V 50mA

Storage Temp

: -40

°

C to 80

°

C

Certified operating temperature: 

-10

°

C to 40

°

C

Nominal working temperature:

 -30

°

C to 70

°

C

Accessories

: Wall and Ceiling brackets

Emissions

: EN55022 Class B

Immunity

: EN50130-4

The Installation of The KX15DD

CABLE ENTRY

KNOCKOUT

CASE LID

SCREW FITTING

The KX15DD Casing

Wall Mounting

NOTE: When

mounting the

detector, ensure 

that it is not

tilting backwards.

KX15DD

KX15DD

Control Panel

Control Panel

Control Panel

KX15DD

Control Panel

KX15DD

Control Panel

KX15DD

Wall Bracket Fitting

Ceiling Bracket Fitting

Auto Sensitivity

Normally Closed Wiring

Zone Doubling Example (Matrix 424,832 or 832+)

Two DEOL Detectors To One Input

Single End of Line Wiring (SEOL)

Double End of Line Wiring (DEOL)

Remote LED Enable

High Sensitivity

Low Sensitivity

OFF

ON (Default)

SENSITIVITY SETTINGS:

Auto, High or Low.

See the diagams below

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

Alarm LED

Pyro Sensor

EOL Resistance 

Headers

EOL Resistor Headers

The KX15DD Printed Circuit Board

The Wiring Connections For The KX15DD (Examples using 4k7 for alarm, 4k7 for tamper)

The KX15DD has two sets of header pins on the PCB, one on

either side of the connector blocks. These headers are used to 

select the End Of Line resistance for EOL wiring applications. 

If EOL wiring is not used, leave the headers OFF.
The set to the left of the + terminal selects the value of the 

resistance across the ALARM relay. The set to the right of the 

TAMPER terminals selects the value of the End Of Line resistor.
If the resistance value you require 

is not selectable, leave the 

headers off and wire a resistor 

of the required value between the 

appropriate terminals as shown.

The KX15DD has a terminal marked ‘LED’ which can be used

to enable the LED in walk test only on a alarm control panel. 
This is used when the LED is disabled via the LED ON/OFF link.
To enable this feature, the LED terminal needs to be connected

to an Output at the alarm control panel. When the system is

is in walk test mode the Output should be at 0V. 
The Output would be usually programmed as “Remote LED

enable”.

The KX15DD sensitivity is selected by 

the two headers located at the bottom 

of the PCB 
The sensitivity can be either AUTO, 

HIGH or LOW.
To select either of these sensivities 

please see the diagrams below.

This symbol illustrates 

where the resistors are 

connected internally

6K8

5K6

4K7

2k2

1K

LOW AUTO

AUTO HI

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

+        

      ALARM     TAMPER   LED

Control Panel

Output

(0v in Walk Test)

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

T T

+AUX- Z1 CO

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

+AUX-

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

+AUX-

Link

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

+AUX-

+AUX-

T T

+AUX- Z1 C

O

M

Link

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

This is the default

setting

RINS1038-3

® 

® 

® 

® 

® 

® 

C

D

E

C1

C2

C3

C4

E1

E2

E3

E5

E4

C5

® 

® 

® 

® 

® 

The Installation of The KX15DD

CABLE ENTRY

KNOCKOUT

CASE LID

SCREW FITTING

The KX15DD Casing

Wall Mounting

NOTE: When

mounting the

detector, ensure 

that it is not

tilting backwards.

KX15DD

KX15DD

Control Panel

Control Panel

Control Panel

KX15DD

Control Panel

KX15DD

Control Panel

KX15DD

Wall Bracket Fitting

Ceiling Bracket Fitting

Auto Sensitivity

Normally Closed Wiring

Zone Doubling Example (Matrix 424,832 or 832+)

Two DEOL Detectors To One Input

Single End of Line Wiring (SEOL)

Double End of Line Wiring (DEOL)

Remote LED Enable

High Sensitivity

Low Sensitivity

OFF

ON (Default)

SENSITIVITY SETTINGS:

Auto, High or Low.

See the diagams below

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

Alarm LED

Pyro Sensor

EOL Resistance 

Headers

EOL Resistor Headers

The KX15DD Printed Circuit Board

The Wiring Connections For The KX15DD (Examples using 4k7 for alarm, 4k7 for tamper)

The KX15DD has two sets of header pins on the PCB, one on

either side of the connector blocks. These headers are used to 

select the End Of Line resistance for EOL wiring applications. 

If EOL wiring is not used, leave the headers OFF.
The set to the left of the + terminal selects the value of the 

resistance across the ALARM relay. The set to the right of the 

TAMPER terminals selects the value of the End Of Line resistor.
If the resistance value you require 

is not selectable, leave the 

headers off and wire a resistor 

of the required value between the 

appropriate terminals as shown.

The KX15DD has a terminal marked ‘LED’ which can be used

to enable the LED in walk test only on a alarm control panel. 
This is used when the LED is disabled via the LED ON/OFF link.
To enable this feature, the LED terminal needs to be connected

to an Output at the alarm control panel. When the system is

is in walk test mode the Output should be at 0V. 
The Output would be usually programmed as “Remote LED

enable”.

The KX15DD sensitivity is selected by 

the two headers located at the bottom 

of the PCB 
The sensitivity can be either AUTO, 

HIGH or LOW.
To select either of these sensivities 

please see the diagrams below.

This symbol illustrates 

where the resistors are 

connected internally

6K8

5K6

4K7

2k2

1K

LOW AUTO

AUTO HI

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

+        

      ALARM     TAMPER   LED

Control Panel

Output

(0v in Walk Test)

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

T T

+AUX- Z1 CO

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

+AUX-

T T

+AUX- Z1 C

O

M

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

+AUX-

Link

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

+AUX-

+AUX-

T T

+AUX- Z1 C

O

M

Link

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

+        

      ALARM     TAMPER   LED

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2K2

1K

6K8

5K6

4K7

2k2

1K

5K6

4K7

2K2

1K

+        

      ALARM     TAMPER   LED

LOW AUTO

AUTO HI

LOW AUTO

AUTO HI

This is the default

setting

RINS1038-3

® 

® 

® 

® 

® 

® 

C

D

E

C1

C2

C3

C4

E1

E2

E3

E5

E4

C5

® 

® 

® 

® 

® 

Minimum 

Range (0m)

Maximum

Range (10m)

Not 

Recommended

EN50131-2-4:2008

EN50131-1:2006+A1:2009

PD6662:2010

Security Grade 2

Environmental Class II

The total weight of several 

small pets should not exceed 

24kg (55 pounds)

NOTE: AUTO SENSITIVITY 

CAN ONLY BE USED ON THIS 

PET IMMUNE DETECTOR

Avoiding False Alarms

1. Avoid placing the detector in direct sunlight.

2. Do not mount the detector near heaters or 

radiators.

3. Do not mount the detector near open windows or 

air vents as draughts may cause false alarms

4. Mount the detector on a stable surface.

5. Do not run cable parallel to mains wiring.

IMPORTANT NOTE:

AVOID INSTALLING THIS DETECTOR 
LOOKING AT A STAIRCASE. 

Do not partially or completely obscure the detector’s 

field of view with large objects such as furniture.

Отзывы: