SWITCH   FEATURE              POSITION       MEANING 

A

LED Enable             ON

     LED Enable

                                OFF          LED Disable

       B            50/60 Hz                  ON            50Hz

                                                      OFF          60Hz

      C               And/Or                   ON            And
                       
                                                      OFF         Or

D          Digital signal             ON

     SPP+

                    Processing

                                OFF

    SPP+1

0C03

PYRONIX LTD                                                          

INSTALLATION

1

. Remove case lid by unscrewing fixings screw as illustrated in 

    and unclip the PCB, taking care not to touch the Pyro sensor

    labeled         .

2

. Choose wall fixing holes, labeled         and        on diagram.

3

. Mark wall for fixing positions (Do not route wires near mains cabling,

    avoid vibrating surfaces and mount only on a solid wall). 

4

. Drill fixing holes. 

5

. Fix case to wall.

6

. Replace PCB again taking care not to touch the pyro sensor (labeled

            on diagram).

7

. Select and fit the appropriate lens for your application (See diagram        ).

8.

 Using dip switches (See diagram        ) select required features and modes of

 

    operation.

9.

 Carry out walk test.

10.

 Re fit detector front cover using fixing provided (See diagram        ).

POTENTIAL FALSE ALARM HAZARDS.

               

1

. Direct sunlight on detector may cause false alarms.

2

. Pets and animals may cause false alarms.

3

. Mounting detector near heaters may cause false alarms.

4

. Draughts from open windows may cause false alarms.

GB

C1

G2

G1

C2

G1

C1

D2

D3

DIP switches (see diagram      )

Note:  As Factory Default all switches are ON

1

1

1A

1A

1B

1B

1C

1C

2

2

3

3

3A

3A

3B

3B

4

4

5

5

6

6

7

7

OPERATION OF FEATURES

1. LED Enable / Disable  (Switch A) 

ON

   =   LED Enable

OFF

 =   LED Disable

2. 50/60 Hz (Switch B)

Factory set

3. And /Or (Switch C)

AND

 = Conventional dual tech, both technologies need to be 

triggered simultaneously to generate an alarm.

OR

 = If either single technology detects prolonged intruder activity

an alarm will be generated independently.

Immunity testing carried out in AND mode.

    

4. Digital signal processing settings  (Switch D)

SPP+    = 

Two opposing detection zones must be crossed.   

SPP+1  = 

Two opposing detection zones and any other zone must be 

                 crossed.

 

        

 

 

 

                            

       

 

      

       

  

 

 

 

 

 

    

     

 

OPTIONAL TAMPER UNIT

Note: The Kudos detector may be fitted with an optional back tamper, which is sold separately.

SPECIFICATIONS (QUICK REFERENCE)

Model:                             

Kud

o

s DT 

Casing:                            White3mm ABS Back / Front cover

                                        White 3mm HDPE lens cover, 0.7mm in faceted area      

Lens:                               Volumetric: 15m, 74 zones, 7 planes, 2.4m mounting height

                                        

                                       .

Detection method:           Low noise dual element pyroelectric  microwave             

Digital signal processing: SPP+ , SPP+1, 

Detection speed:             0.3 - 3.0 m/s

Operating  Voltage:         9-16 VDC        

Current consumption:     40mA Quiescent

@13.8V                          35mA  Alarm

                                     

Relay Output:                 60Vdc, 50mA (42.4Vac peak)                

Mounting Height:            1.8 - 2.4m           

Tamper Switch:              Normally closed voltage free contacts 

                                       (12V 50mA max rating)

0

0

0

0

Storage Temp:               -40   C / 80   C (-40   F / 176   F )    

0 0

0

0

Operating Temp:           -30  C / 70   C (22   F / 158   F )            

Emissions:                     EN55022 Class B                                             

Immunity:                       To new European Standard EN50130-4

Accessories:                  Optional back tamper

.

C

I

al at on

nst l i

   Mo

i

w t back amper

  

unt ng  i h 

t

      Fla  

nst a  al

      

t agai

  w l

      C ner  ount

       or

m

ed

        

D

ee on  all

     45  egr

 

w

  C   t th t mp  

t on

    ut ou

e a

er posi i

     equi ed, 

i g  cal el or shar

 

r

r

us n s

p

 

    i i y kni e

  ut l t

f

     Orie ation of t

p  

t

 

nt

  am er uni

       Lef  hand  de

      

t

si

      R ght han side

       i

 

   

  

  E

e a per sw t h le e

    nsur t m

 

i c   v r

  i cor e tly  r ent ed

   s 

r c

o i

at

    osition swi ch 

 tam

pl e.

  P

t

and

per  at

  Posi i

uni  wi hi detecto ,

   

t on 

t

t n 

r

  usi

st

 thr

 or  i

a io

   

ng  ep

ee, f

or ent t n

      o  

t  

   

f uni .

    nsur cl p i ur

ar  l c te

  E

e  i f xt es  e o a d

     in t

cor ect po i i

, on  he 

 

he 

r

 

s t on

t

  out  sur ace   he cas ng.

   

er

f

of t

i

 

  

WARRANTY

This product is sold subject to our  standard warranty  conditions and is  warranted against 

defects in workmanship for a period  of two years. In the interest of continuing  improvement 
of quality, customer care  and design, Pyronix Ltd  reserve the  right to amend specifications 

without giving prior notice 

B

A1

A

G

C

A2

C1

C2

C3

D1

D

D2

D3

E

F

F1

F2

F3

G1

G2

DIAGRAMS

     Coverage patterns.     

     PIR coverage pattern and plan view.

     Microwave coverage pattern.

     Dimensions and weight.

     Board layout.

     Pyro sensor.

     DIP Switches.

     Optional rear tamper.

     Mounting and cable entry knockouts.

     Cable entry knockouts.

     Wall fixing knockouts.

     Wall fixing knockouts.

     Detection methods.

     Detailed connections.

     Control panel connections.

     Tamper operation.

     Alarm relay operation (N/C)

     Removal and replacement of front cover and lenses.

     Front cover fixing screw.

     Removing and replacing the lens.

C

H1                 H2                H3                   H4

Power up             Normal alarm      Micowave                 PIR
 

    

 

R

RINS 451-5

This product is approved for use in the 

Residential, Commercial and Light Industrial Environment.

Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND

Customer Support: 
+44(0)845 6434 999 (local rate)
or +44(0)1709 535225 
Hours: Mon to Fri, 8:00am till 6:30pm
Email: [email protected]
Website: www.pyronix.com

LED INDICATIONS

K

udos DT 

 

This product complies with TS50131-2-4. at security grade 2, 

environmental class 2.

UK = Suitable for use with systems installed to PD6662:2004 (AMD)

EXPORT = Suitable for use with systems installed to EN50131-1

D

Frequencies Countries 

AT, BE, CH, CY, CZ,
DK, FI, FR, GR, HU, IE,
IS, IT, LT, MT, NL, PL,
SI, TR

 

BE, CH, CY, DK, HU,
IE, IS, IT, MT, NL, NO, 
SE, SI

 

GB

 

9.9Ghz

 

10.5Ghz

 
10.6Ghz

 

This product operates is a 
European non-harmonised
frequency band

Hereby, Pyronix, declares that this Kudos DT
is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
The declaration of conformity may be consulted at
www.pyronix.com/DoC

!

2

TS50131-2-4
EN50131-1
PD6662:2004

Security Grade 2
Environmental Class 2

Отзывы: