0C03
PYRONIX LTD
INSTALLATION
1.
Remove the case lid by unscrewing the fixing screw illustrated in.
2.
Remove the lens as shown in.
3.
Remove the PCB, taking care not to touch the pyro sensor labeled.
4.
Choose wall fixing holes, labeled and on diagram.
5.
Mark wall for fixing positions (Do not route wires near mains cabling,
avoid vibrating surfaces and mount only on a solid wall)
6.
Drill fixing holes
7.
Fix the case to the wall.
8.
Replace the PCB taking care not to touch the pyro sensor, labeled
9. Using the DIP switches (See diagram ) select the required
features and modes of operation.
10. Carry out walk test.
11. Refit the case lid and lens as shown in and
POTENTIAL FALSE ALARM HAZARDS.
1
. Direct sunlight on detector
2
. Pets and animals
3
. Mounting detector near heaters
4
. Draught’s from open windows
GB
C
H1
D3
H2
C1
C1
C2
H2
D2
H1
B2
B
A
A
B3
B1
C
D
F
E
F1
F2
F3
F4
F5
G
H
H1
H2
H1 H2 H3 H4
Power up. Normal alarm. Micowave. PIR
DIP switches (see diagram )
Note: As Factory Default all switches are ON
LED INDICATIONS
SPECIFICATIONS (QUICK REFERENCE)
Model: Kudos AM 3 in 1
Casing: White 3mm ABS Back / Front cover
0.7mm HDPE in lens area
Lens: Volumetric: 15m, 74 zones, 7 planes, 2.4m mounting height
Curtain 25m, 24 Zones, 6 planes, 5m mounting height
Long Range 45m, 46 zones, 6 planes, 2.4 mounting height
.
Detection method: Low noise dual element pyroelectric microwave
Digital signal processing: PC1, SPP+
Detection speed: 0.25 - 2.5 m/s
Operating Voltage: 9-16 VDC
Current consumption: 40mA Quiescent
@13.8V 35mA Alarm
105mA self test (short burst per test)
Relay Output: 60Vdc, 50mA (42.4Vac peak)
Mounting Height: 1.8 - 2.4m Volumetric
1.8 - 5.0m Curtain
1.8 - 2.4m Long Range
Tamper Switch: Normally closed voltage free contacts
(12V 50mA max rating)
0
0
0
0
Storage Temp: -40 C / 80 C (-40 F / 176 F )
0 0
0
0
Operating Temp: -30 C / 70 C (22 F / 158 F )
Emissions: EN55022 Class B
Immunity: To new European Standard EN50130-4
Accessories: Optional back tamper
PIR sensor
failed self test.
H6
Mask processing in progress.
H7
Indication of a valid mask activation.
Note:
The technology
which has failed will be
indicated by a cylic flash
and pause of the LED.
H5
Microwave sensor
failed self test.
9.
E- Remote LED enable terminal
To use the remote LED enable feature switch A must be in the OFF position.
9.1 Connections
To remotely enable LEDs 0 volts must be applied to the E- terminal.
9.2 Pyronix panels
Connect detector input E- to a PGM output and configure as walk test.
R
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
OPERATION OF FEATURES
1. LED Enable / Disable (Switch A)
ON = LED Enable (Override the E- control)
OFF = LED Disable (E- controls the LEDs)
ON:
The detector operates in AM dual mode
OFF:
The detector operates in
AM PIR mode only and is intended for
use with a curtain or long range lens only.
In AM PIR mode, a triggering of the PIR causes the alarm relay to open
and the alarm LED to turn on. The PIR and Microwave LEDs are disabled.
Mask processing will work the same in both modes, i.e. the microwave signal
will be used to reset mask processing or a latched mask event
2. Operational Mode (Switch B)
OR
= If either single technology detects prolonged intruder activity
5. And /Or (Switch E)
AND
= Conventional dual tech, both technologies need to be
triggered simultaneously to generate an alarm.
an alarm will be generated independently.
Immunity testing carried out in AND mode.
7. Relay mode (Switch G)
ON
= Relay is in normally closed mode. (N/C)
OFF
= Relay is in normally open mode. (N/O)
8. 50/60 Hz (Switch H)
Factory set.
K
udos AM
3 in 1
The KUDOS AM incorporates a unique anti-masking feature which will
prevent the alarm panel from being set if an attempt to block the PIR or
Microwave coverage pattern is detected. When something moves in close
proximity to the detector an anti-mask processing sequence will be
activated. This is indicated by the Red LED which will flash at half second
intervals. Processing will normally take 60 seconds to complete and during
this time the detector mask relay output will remain closed. If the detector
verifies that an attempt to block its coverage has been made then the
appropriate relay(s) will open (according to the alarm relay mode switch).
The relay(s) will remain open until the block has been removed. In addition
the Green and Orange LEDs will turn on regardless of whether LED disable
has been selected. To reset the detector to normal operating mode, remove
the blocking material, while the RED alarm LED is flashing the detector should
be walk tested to activate both technologies. After 60 seconds the RED alarm
LED should stop flashing. When the RED Alarm LED is no longer flashing the
detector should be walk tested again to activate both technologies. Under
certain conditions it may be possible for anti-masking system not to recognise
masking of one technology only. See Options
5
&
6
.
NB. The above description assumes the relay mode switch G is set to
Normally Closed.
Mask sensitivity adjustment is provided by a potentiometer on the PCB.
Maximum sensitivity is achieved when the pot is turned fully clockwise.
To disable the anti-masking feature the pot should be turned fully counter
3. Mask (Switch C)
ON
= Only mask relay opens and stays open upon mask processing
concluding a genuine mask situation has occurred.
OFF
= Mask and alarm relays open and stay open upon mask processing
concluding a genuine mask situation has occurred.
ANTI - MASKING Refer to
MASK - ADJUSTMENT Refer to
F3
C
clockwise.
.
RINS845-3
This product complies with TS50131-2-4. at security grade 3,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
SWITCH
FEATURE
POSITION MEANING
A
LED Enable
ON
LED Enable
OFF
LED Disable
B
Operational
ON
Dual Tech Mode
Mode
OFF
AM PIR Mode
C
Mask Relay
ON
Open Mask relay
Action
only when in mask
OFF
Open Mask and Alarm
relay when in mask
D
PIR
ON
SPP+
Processing
OFF
PC1
E
AND/OR
ON
AND mode is functional
OFF
OR mode is functional
F
Mask
ON
Normal Anti Mask Security Mode
Security Mode
(Anti-Block)
OFF
High Anti Mask Security Mode
G
Relay Mode
ON
Relays Normally Closed
OFF
Relays Normally Open
H
Frequency of ON
50Hz
Operation
OFF
60Hz
4. PIR Signal Processing (Switch D) refer to
PC1
= One detection zone must be crossed
SPP+
= Two opposing detection zones must be crossed
E
6. Mask Security Mode (Switch F)
ON
= Normal Anti Mask Security Mode
OFF
= High Anti Mask Security Mode
Single Technology Masking can be prevented by using the Normal/High Anti
Mask Security Mode function. Switch F to OFF (Anti-Block)
When this mode is selected the RT input must be connected to a control
panel programmable (PGM) output.
When the panel is disarmed this input must be at 0V. When the panel is
armed the input must switch to 12V.
If an attempt to mask the detector is made during a disarmed state, then the
alarm relay will be held open until the detector masking is removed.
This fault is displayed as shown in diagram H7.
65mm
55mm
155mm
WEIGHTS AND
DIMENSIONS
Kg
79.2 g
Weights And Dimensions
Coverage Patterns
15m Volumetric Lens
25m Curtain Lens
45m Long Range Lens
Board Layout
Mounting & Cable Entry
PIR Detection Methods
Wiring to Control Panel
Remote LED Enable
Tamper Operation
Mask Operation
Normally Closed Operation
Normally Open Operation
Optional Tamper Unit
Front Cover & Lenses
Removing Cover
Removing Lens
Diagrams
WARRANTY
This product is sold subject to our standard warranty conditions and is warranted against defects in
workmanship for a period of two years. In the interest of continuing improvement of quality, customer care and design,
Pyronix Ltd reserve the right to amend specifications without giving prior notice.
Single technology masking can be prevented by switching switch E to OFF
(OR mode is functional).
TS50131-2-4
EN50131-1