background image

OUTPUT A & B Wiring:

Learning Inputs:

Signal Strength Indicator:

Learning Keyfobs:

FAULT OUTPUT Wiring:

ARM / DISARM:

UR2-WE

 

 Dual channel universal receiver   

 for Enforcer inputs and keyfobs

0845 6434 999 (UK). +44(0)1709 535 225

  

*

 [email protected]   

 

www.pyronix.com   

Pyronix Limited,Pyronix House,Braithwell Way, Hellaby, Rotherham, S66 8QY, UK  

 

           RINS1702-4

Environmental Class II

E N G L I S H

15s

≤300s

≤300s

>5s

>5s

0-9

0-9

A-F

≤300s

FAULT

FAULT

Technical Information Summary:

(SLOW)

(LENTO)

(FAST)

(VELOCE)

Product Information

Warranty

START

Each output allows a maximum of 10x Wireless Inputs and 6x Wireless 

Keyfobs to be learnt. The relays will wire directly to an input on the 

control panel (normally open or normally closed).The outputs should be 

connected to an input programmed according to the device learnt (e.g. 

Keyswitch input for keyfobs, or Intruder input for wireless devices)

 

Fault Output: 

This output will activate if there are any of the following faults:

Low Battery

  /  

Jamming  

/  

Supervision

   /  

Tamper

The output should be connected to an input programmed as ‘Fault’.

 Arm / Disarm Status:

 

In order to receive alarm events from learned devices, the 'ARM' terminal 

should be connected to an output that monitors the ARM/DISARM status of 

the control panel. The shown dip switch is used to select 0v or 12v applied 

when the control panel is armed. 

PIR’s will only trigger a channel relay if the UR2 is in an Armed State.

 Learning Inputs:

 

It is recommended that all inputs are learnt to one output (e.g. OUTPUT A) 

and all keyfobs are learnt to the other output (e.g. OUTPUT B) -A dot next 

to the letter/number indicates that an Input is connected to OUTPUT B.

  Learning Keyfobs:

 

If learning keyfobs, the control panel input should be programmed as a 

keyswitch.

  Signal Strength Indicator:           

                                                         

Shows the following for each input learned:

A

’:Excellent. ‘

B

’:Good. ‘

C

’:Bad. ‘

     ’:

Waiting for response/out of range

 

Event Log /History: (Events display in realtime AND in Event logs)

 

Clearing the Event Log       Deleting Inputs           Deleting Keyfobs

                         

 

Pulse Outputs:

 

Keyfob:

 Pressing      ,     or  

 on the keyfob will activate the relay for the 

pulse time (3 or 60 seconds).

Input:

 The output will activate for the pulse time (3 or 60 seconds) after 

an input has activated. The pulse time will only be reset once all inputs 

are in a closed state.
Pressing  

II

 

will display the UR2 status

 RED LED = ARMED, GREEN LED = DISARMED, ORANGE LED = FAULT

 Toggle Outputs:

 

Keyfob:

 

Pressing only the      button on the keyfob will activate the relay. 

Pressing only the      button will deactivate the relay.

Pressing 

 I

 

will display the error LED (blinks orange 4 times).

Input:

 The output will activate after an input has activated. The output 

will only be reset, when either the same input is activated again, or a 

different input is activated.
Pressing  

II

 

will display the UR2 status (same as pulse mode).

 Walk Test Mode:

 

The channel relay will open for 3 seconds and then the relay will close 

again after a successful walk test.

Output A and Output B:

OUTPUT

  (A/B) 

OUTPUT

  (A/B) 

OUTPUT

  (A/B) 

OUTPUT

  (A/B) 

FAULT

FAULT

Control 

Panel

UR2-WE

+12VDC

Supply

POWER SUPPLY

1

0

DISPLAYS EVENTS IN ORDER ONCE DISARMED

MOSTRA GLI EVENTI ORDINE UNA VOLTA DISARMATO

Supply Voltage:                     9V – 15V
Current Consumption:           80mA (min) – 400mA(max, all outputs active)
Output A:                              3A @ 30VDC

Output B:                              3A @ 30VDC  

Fault:                                    3A @ 30VDC
Arm / Disarm status:              0V (0V ARM), 9-15V (12V ARM)
Radio Frequency:                  868MHz, FM Transceiver Narrow Band
Dimensions Plastic Box:         173x125x32mm 
Dimensions PCB:                    135x90x15mm
Operational Temperature:    -10°C to +50°C
Storage Temperature:           -40°C to +80°C          
Humidity:                               85% @ 25°

For electrical products sold within the European Community. At the end of the electrical products 

life, it should not be disposed of with household waste. Please recycle where facilities exist. Check 

with your Local Authority or retailer for recycling advice in your country.

To prevent possible damage to components, any static charge on your body needs to be eliminated 

before touching the inside of the unit. This can be accomplished by touching some rounded/earthed 

metallic conductor such as a radiator/pipework immediately before handling the product.

This product is sold subject to our standard warranty conditions 

and is warranted against defects in workmanship for a period of 

two years. In the interest of continuing care and design, Pyronix 

Ltd reserves the right to amend specifications, without giving 

prior notice.Please see the control panels programming manuals 

for further information.

M

N/C (Normally Closed)

N/O (Normally Open)

N/O  DEOL

N/C  DEOL

N/C (Normally Closed)

N/O (Normally Open)

N/O  DEOL

N/C  DEOL

= ALARM

= TAMPER

= ALARM

= TAMPER

Example Disarm Status 

after Alarm (Output A)

0V   

12V

0V   

12V

12V

ARM

0V

ARM