background image

KH-ES4850

KH-ES4850 POWER CABINETS

Owner’s Manual

Version 1.0

KH strongly advises to take due care in following the owner’s manual.
A warranty claim is invalid if damage is caused by human error, inconsistent

Содержание KH-ES4850

Страница 1: ...ES4850 KH ES4850 POWER CABINETS Owner s Manual Version 1 0 KH strongly advises to take due care in following the owner s manual A warranty claim is invalid if damage is caused by human error inconsist...

Страница 2: ...res 8 2 2 Specification 9 2 3 Equipment interface instruction 11 Definition of RJ45 Port Pin 13 3 Safe handling of lithium batteries guide 15 3 1 Schematic diagram of solution 15 3 2 Danger label 15 3...

Страница 3: ...or or a third party Une op ration ou un travail incorrect peut causer 1 blessure ou mort l op rateur ou un tiers 2 Dommage au mat riel du syst me et d autres propri t s appartenant l op rateur ou un t...

Страница 4: ...personal injury Risque d endommagement du syst me de batterie ou de blessure corporelle DO not pull out the connectors while the system is working NE PAS debrancher les connecteurs lorsque le syst me...

Страница 5: ...mortelles sont pr sentes dans les bornes et les c bles de la batterie Des blessures graves voire mortelles peuvent survenir si les c bles et les bornes sont touch s Do not connect battery with PV sola...

Страница 6: ...t tre r alis conform ment la Norme NFPA70 Do not expose cable outside Ne pas exposer le c ble l ext rieur Any foreign object is prohibited to insert into any part of battery Il est interdit d ins rer...

Страница 7: ...age pour nettoyer la batterie Do not paint any part of battery include any internal or external components Ne pas peindre aucune partie de la batterie y compris les composants internes ou externes Ple...

Страница 8: ...e est teinte Wiring must be correct do not mistake the positive and negative cables and ensure no short circuit with the external device Le c blage doit tre correct ne pas confondre les c bles positif...

Страница 9: ...ype Please do not open repair or disassemble the battery except staffs from Keheng or authorized by Keheng We do not undertake any consequences or related responsibility which because of violation of...

Страница 10: ...and long cycle life 3 Battery management system BMS has protection functions including over discharge over charge over current and high low temperature 4 The system can automatically manage charge an...

Страница 11: ...9 Positive Terminal ADD Dialer DRY CONTACT Negative Terminal SS Handle ON OFF Button Reset Key Run Indicator Light Electricity Volume Indicator RS485 Port CAN Port RS232 Port RS485 Port RS485 Port...

Страница 12: ...5 Max Charge Discharge Current A 50 Peak Charge Discharge Current A 100A 15sec Communication RS485 RS232 Depth of discharge 90 Configuration max in 1 battery group 4pcs Working Temperature 0 50 Charge...

Страница 13: ...g to show the battery running status Alarm Red LED flashing to show the battery has alarm lighting to show the battery is under protection SOC 6 green LEDs to show the battery s current capacity ADD S...

Страница 14: ...o1 Output1 On stop charge Com No2 Output2 On stop discharge Com No3 Output3 On BMS error Output request signal voltage 25V 500 Kbps 120 recommended For connection to LV HUB inverter 9600 or 115200 bps...

Страница 15: ...Pin3 Pin4 CAN H Pin5 CAN L Pin6 GND Pin7 RS485A recommend Pin8 RS485B recommend Power Terminals Power cable terminals there are two pair of terminals with same function one connects to equipment the...

Страница 16: ...flash on 0 5s off 0 5s Discharge Show soc Alarm ALR Other LEDs are same as above System error Protect ON flash on 0 3s off 3 7s flash on 0 5s off 1 5s BMS basic function Protection and alarm Managemen...

Страница 17: ...15 3 Safe handling of lithium batteries guide 3 1 Schematic diagram of solution 3 2 Danger label...

Страница 18: ...ectric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their tips with electrical tape 3 4 Safety gear It is recommen...

Страница 19: ...for each battery package 2 For battery system connects to inverters Two long power cables current capacity 120A constant 100A and one communication cable for each energy storage system NOTE These thr...

Страница 20: ...C 5 The temperature and humidity are maintained at a constant level 6 There is minimal dust and dirt in the area 7 The distance from heat source is more than 2 meters 8 The distance from air outlet o...

Страница 21: ...nt exposure to harsh temperatures may deteriorate the performance and life of the battery pack Si la temp rature ambiante est hors de la plage de temp rature de service la batterie cesse de fonctionne...

Страница 22: ...connection point of room or installed place shall smaller than 0 1 1 based on metal directly touch between the module s surface and rack s surface If using painted rack the corresponding place shall...

Страница 23: ...limentation est de 120 A Si le courant de conception de la cha ne de batterie est sup rieur 100 A il est n cessaire d utiliser au moins 2 paires de c bles d alimentation externes pour tendre la capaci...

Страница 24: ...different SOC voltage of module together please maintain the system in idle for 15mins or till the SOC LEDs becomes similar 1dot difference before normal operation 4 5 Power off 1 Turn external power...

Страница 25: ...nitor tools to check the battery log If battery terminal voltage is 45Vdc please use 0 05C to slowly charge the module to avoid affect to SOH If battery terminal voltage is 45Vdc it can use 0 5C to ch...

Страница 26: ...d discharge with red LED on The temperature is 0 50 degree Use charger to charge not possible Use load to discharge not possible g Under permanent protection The single cell voltage has been higher th...

Страница 27: ...scribed below a Inhalation Evacuate the contaminated area and seek medical attention b Contact with eyes Rinse eyes with flowing water for 15 minutes and seek medical attention c Contact with skin Was...

Страница 28: ...battery pack seems to be damaged pack it in its original container and then return it to Keheng or an authorized dealer Danger Damaged batteries may leak electrolyte or produce flammable gas Les batt...

Страница 29: ...6 months for this charge maintenance make sure the SOC is charged to higher than 90 2 Every year after installation The connection of power connector grounding point power cable and screw are suggeste...

Страница 30: ......

Страница 31: ...MasLitio M xico Avenida Reforma Agraria 121 2A Colonia 5 Se ores Oaxaca C Dolores 4 Altos 203 Col Centro Alcald a Cuauht moc Cd M xico Website maslitio com Tel 951 310 5323...

Отзывы: