cuff inflates, and your pulse and blood pressure measurement is taken. 

5)

 

When  completing  the  test,  the  cuff  will  automatically  deflate  and  the  test  result  will 

display on the screen as shown on fig 13. 

6)

 

You may turn off the unit or compare with the previous results 

7)

 

Automatic shut off in 3 minutes. 

8)

 

If a problem occur during the test, “Err ” will display on the screen. 

9)

 

In  the  end  of  measurement,  “

”  will  display  on  the  screen  when  irregular  pulse  is 

detected.   

 

 

  

 

 

 

 

         

Fig

 10             

Fig

 11             

Fig

 12            

Fig

 13 

Notes: 

 

Do  not  self-diagnosis  according  to  measurement  results.  Follow  the  instructions  of  your 

physician or licensed healthcare provider. 

 

The blood pressure monitor only will remind the end user on high blood pressure as follows: 
When the systolic pressure is greater or equal to 140mmHg and/or when the diastolic pressure 
is greater or equal to 90mmHg as abnormal.    The display will flash to remind the end user of 
the blood pressure abnormality.   

 

If the device caused any discomfort during measurement or fail to perform as indicated, turn 
off the power or discontinue use.   

 

The time of the pressure reduced from 260mmHg (34.67kPa) to 15mmHg (2kPa) does not 
exceed 10s. 

 

If cuff inflated up to 300 mmHg (40 kPa) doesn’t stop, please remove the cuff or power off 
the unit 

 

4.5 Bluetooth Connection and Data Transmission

 

The Bluetooth  can  be  turned  on  after  the  device  is  connected  to  the AC  adapter  or  you  have 

installed  the  batteries,  the  device  can  transmit  data  to  the  PHBP  Blood  Pressure  App  by 

Bluetooth.   

Download and install the PHBP Blood Pressure App on your Android or iOS device 

Please be sure that Bluetooth is turned on your device   

Search  for  the PHBPB16TL  on  your  device.  Once  the  device  is  found  select  it  for  automatic 

pairing. 

Start the PHBP Blood Pressure App and follow the directions included in App. 

 

Содержание PHBPB16TL

Страница 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Страница 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Страница 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Страница 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Страница 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Страница 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Страница 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Страница 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Страница 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Страница 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Страница 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Страница 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Страница 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Страница 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Страница 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Страница 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Отзывы: