background image

 

3.3 Setting 

1)

 

With monitor power off 

2)

 

Hold the

S

button for 3 seconds, Year digits blinking 

a)

 

Change number

 

Press the memory button to advance one number                                 

 

Hold down the 

M

memory button, the number will change rapidly 

b)

 

Enter the two digit of the year number 

c)

 

Press the 

S

button will proceed to month setting 

d)

 

Repeat step a) to c) to set month, day, hour and minutes 

3)

 

Unit Conversion (mmHg to kPa)   

a)

 

Press the memory button will automatically change the unit conversion either from 

mmHg or kPa as shown on Fig 6 or Fig 7. 

b)

 

Complete setting, press Start/Stop button to exit. 

 

 

 

 

       

 

Fig

 6                    

Fig

 7             

 

                     

  

      

 

4 Take a measurement 

4.1 Important Noted 

 

Don't eat, drink alcohol, smoke, take a shower or exercise for at least 30 minutes before you 

take your blood pressure and don't use any medicines that can raise blood pressure. 

 

Try not to take your blood pressure if you are nervous or upset. If you are nervous, anxious, 

or agitated your blood pressure will rise.   

 

Rest for 5

10 minutes before taking a reading. Sit in a comfortable, relaxed position. Don't 

move around or talk while taking the blood pressure. Leave your legs in one position, breath 

freely and calmly.   

 

The blood pressure cuff should fit over about 3/4 of your upper arm. It should easily go 

around the arm and the Velcro should close tightly. 

 

If you can, use the same arm for every reading.   

 

Measuring blood pressure at the same time on different days should give about the same 

reading (excluding outside influences like exercise).   

 

Changes  in medication or nutritional supplement can alter  your result. Please consult  your 

doctor before taking or stopping medications or supplement. 

 

4.2 Fitting the cuff 

1)

 

Plug in the air tube connector into the main unit 

2)

 

Wrap the cuff around the upper left arm or upper right arm. 

Содержание PHBPB16TL

Страница 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Страница 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Страница 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Страница 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Страница 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Страница 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Страница 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Страница 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Страница 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Страница 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Страница 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Страница 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Страница 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Страница 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Страница 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Страница 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Отзывы: