background image

 

NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected 
by absorption and reflection from structures, objects and people. 

 

8

About Blood Pressure                                                                                   

 

8.1 What is Blood Pressure?                                                                                                         

Blood pressure (BP) is the pressure exerted by circulating blood upon the walls of blood vessels, 

and is one of the principal vital signs. 

Two pressures are measured for a blood pressure reading: 

 

Systolic blood pressure is a measure of blood pressure while the heart is beating.   

 

Diastolic pressure is a measure of blood pressure while the heart is relaxed.   

 

8.2 What is high blood pressure?                                                                                             

High blood pressure, also known as HBP or hypertension, is a widely misunderstood medical 

condition. Some people think that those with hypertension are tense, nervous or hyperactive, but 

hypertension has nothing to do with personality traits. The truth is, you can be a calm, relaxed 

person and still have HBP. Let's look at the facts about blood pressure so you can better 

understand how your body works and why it is smart to start protecting yourself now, no matter 

what your blood pressure numbers are. 

By keeping your blood pressure in the healthy range, you are: 

 

Reducing your risk of your vascular walls becoming overstretched and injured 

 

Reducing your risk of your heart having to pump harder to compensate for blockages 

 

Protecting your entire body so that your tissue receives regular supplies of blood that is rich in 

the oxygen it needs 

According to World Health organization standard, the blood pressure level classification and 

definition as following: 

Category 

Systolic

mmHg

 

Diastolic

mmHg

 

Desirable 

120                    and 

80 

Normal   

120-129        and/or 

80-84 

Pre hypertension 

130-139        and/or 

85-89 

Hypertension

 

≥140            and/or 

≥90 

  Stage 1 Hypertension 

140-159      and/or 

90-99 

  Stage 2 Hypertension 

160-179      and/or 

100-109 

Hypertensive Crisis 

≥180            and/or 

≥110 

These categories were defined by the American Heart Association. This chart applies to adults 
age 20 and older. 

 

 

 

Содержание PHBPB16TL

Страница 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Страница 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Страница 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Страница 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Страница 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Страница 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Страница 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Страница 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Страница 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Страница 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Страница 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Страница 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Страница 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Страница 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Страница 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Страница 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Отзывы: