PVI Industries TURBOPOWER 500 N 750A-TPL Скачать руководство пользователя страница 1

Product is patented in the U.S., Canada, and Mexico. 

 

PVI INDUSTRIES, LLC 

FORT WORTH, TEXAS 76111 

PV 6549  11/07

 

(800) 784-8326  

  www.pvi.com 

LOW NO

x

 TURBOPOWER

®

 • PACKAGED WATER HEATER 

NICKELSHIELD

®

 NICKEL-PLATED STORAGE TANK 

TANK SERIES 750 GALLONS VERTICAL

 

 

MODEL 

NUMBER 

Recovery gph

 

c

 

INPUT 

Btu/h 

Min. Inlet 

Flow Gas 

Pressure 

" W.C. 

e

 

SCAQMD Energy 

Model No. 

Dimensions 

(inches)

 

Blower  

Motor 

Shipping

Weight

lbs  

40° - 120°F  40° - 140°F 

d

 HP Amps 

500 N 750A-TPL 

500 

400 

399,000 

4.5 

4TPL 

399 MBtu/h 

28 

3/4 

16 

1/3 

2660 

c

 Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. 

d

 “J” dimension is for the burner housing only – gas train may exceed this dimension. 

e

 Standard gas train. 

*  The information presented is for natural gas 0.6 S.G. 
  Dimensions are in inches unless otherwise specified. 
  For standard and optional equipment, see form #PV6540. 

 
 
 
 
 

 

 
 
 
 
 

STANDARD GAS PRESSURE REQUIREMENTS:

 

 

STANDARD ELECTRICAL REQUIREMENTS:

 

SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER. 

MAXIMUM STATIC INLET GAS PRESSURE IS 

14" W.C. 

FOR GAS PRESSURES OUTSIDE OF THIS RANGE,  

CONTACT YOUR PVI REPRESENTATIVE. 

 

CONTROL VOLTAGE:

  120V, 1Ø, 60 HZ., 2 AMPS. 

MOTOR VOLTAGE:

  1/3 HP ARE 120V, 1Ø, 60 HZ. 

 

  208V, 230V AND 460V MOTORS ARE AVAILABLE BUT WILL 
  REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN 
  OPTIONAL CONTROL CIRCUIT TRANSFORMER.

 

 

 

 

VENTING REQUIREMENTS:

 

 

 

-.02" TO -.06" W.C. (NEGATIVE PRESSURE). 

TYPE B VENTING. 

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON 

THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK 

NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED."

 

 

 

 

 

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND 

SPECIFICATION WITHOUT NOTICE. 

 

Отзывы: