Dimensions are in inches unless otherwise noted.
For standard and optional equipment, see form # PV 6811.
* When connected with field provided 3” x 4” adapter of the same material as required for venting (see I&M).
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN
AND SPECIFICATION WITHOUT NOTICE.
STANDARD GAS PRESSURE REQUIREMENTS
VENTING REQUIREMENTS
MINIMUM FLOW GAS PRESSURE: 4.5" W.C.
MAXIMUM STATIC GAS PRESSURE: 10.5" W.C.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
CATEGORY IV - POSITIVE PRESSURE, CONDENSING.
UL CLASSIFIED FOR SCHEDULE 40, SOLID-WALL PVC OR CPVC PIPE.
“SANI” TEMPERATURE HEATER REQUIRES CPVC VENT PIPE
SEE INSTALLATION MANUAL FOR VENTING
AND DIRECT COMBUSTION AIR GUIDELINES.
STANDARD ELECTRICAL REQUIREMENTS
120V, 1Ø, 60 HZ.
MAXIMUM AMP DRAW (TRIAL FOR IGNITION): 6
CONTINUOUS AMP DRAW WHEN FIRING: 1.3
CONTINUOUS AMP DRAW DURING STANDBY: 0.03
PV 6812 09/08
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
(800) 784-8326
y
www.pvi.com
This product is protected by patents in
the U.S., Canada and Mexico.
MODEL NUMBER
X
199 SS A-PN
299 SS A-PN
399 SS A-PN
Input Btu/h
199,000 299,000 399,000
GPH Recovery Rate at 40°F to 140°F
221
340
444
Approximate Shipping Weight - lbs
1000
1100
1100
Flue Connection Diameter - inches
3 *
4
4
Hot Outlet and Cold Inlet - NPT
2
2
2
1st Hour Delivery (100°F
Δ
T) - gallons
289
397
501
Storage Capacity - gallons
80
70
70
PLATINUM
®
• CONDENSING GAS WATER HEATER
STAINLESS STEEL TANK
TANK SERIES 70 GALLONS