PVI Industries 250N600A-TPO Скачать руководство пользователя страница 1

  Recoveries based on 83% thermal efficiency.  ASHRAE 90.1 compliant for efficiency and standby loss. 
   "J" dimension is for the burner housing only.  

 

Dimensions are in inches unless otherwise specified. 

 

For standard and optional equipment, see form PV 6006.  

 

Model 

Number 

Recovery gph 

 

Input 

Btu/h 

Dimensions (inches) 

Blower  

Motor 

Shipping 

Weight 

lbs  

40°- 120°F  40°- 140°F 

 

HP 

Volt/Ph/

Amps 

250 P 600A-TPO 

250 

200 

199,000 

28 

17 

1/3 

115/1

/8 

2270 

500 P 600A-TPO 

500 

400 

399,000 

28 

17 

1/2 

115/1

/10 

2290 

750 P 600A-TPO 

750 

600 

600,000 

31 

17 

1/2 

115/1

/10 

2370 

1000 P 600A-TPO 

1000 

800 

800,000 

31 

17 

1/2 

115/1

/10 

2410 

1250 P 600A-TPO 

1250 

1000 

1,000,000 

39 

17 

1/2 

115/1

/10 

2650 

1500 P 600A-TPO 

1500 

1200 

1,200,000 

39 

17 

1/2 

115/1

/10 

2660 

Gph 

#2 Oil 

1.4 

2.8 

4.3 

5.7 

7.2 

8.6 

2000 P 600A-TPO 

2000 

1600 

1,600,000 

11.4 

51 

10 

25 

1-1/2 

115/1

/20 

3100 

2500 P 600A-TPO 

2500 

2000 

2,000,000 

14.3 

51 

10 

25 

1-1/2 

115/1

/20 

3120 

3000 P 600A-TPO 

3000 

2400 

2,400,000 

17.1 

53 

12 

25 

1-1/2 

115/1

/20 

3130 

3500 P 600A-TPO 

3500 

2800 

2,800,000 

20.0 

53 

12 

25 

230/3

/16 

3160 

4000 P 600A-TPO 

4000 

3200 

3,200,000 

22.8 

53 

12 

25 

230/3

/16 

3210 

41 

41 

41 

41 

41 

41 

41 

41 

51 

51 

51 

TURBOPOWER

®

  OIL 

 

PACKAGED WATER HEATER 

POLYSHIELD

®

 

POLYMER-LINED STORAGE TANK

 

TANK SERIES 600 GALLONS  

PV 5440  04/05 

PVI INDUSTRIES, LLC 

FORT WORTH, TEXAS 76111 

(800) 784-8326 

 

(817) 335-9531 

 

www.pvi.com 

Product is patented in the U.S., Canada, and Mexico. 

VENTING REQUIREMENTS 

-.02" TO -.06" W.C. (NEGATIVE PRESSURE) 

 

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED 

UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.  

FOR PROPER SIZING, CONSULT VENTING SUPPLIER. 

STANDARD ELECTRICAL REQUIREMENTS 

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS. 
  MOTOR VOLTAGE:  
  208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL 
  REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN 
  OPTIONAL CONTROL CIRCUIT TRANSFORMER. 

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN 

AND SPECIFICATION WITHOUT NOTICE. 

* REAR ACCESS MODULE 

MODEL PREFIX 

STD or OPTIONAL 

250-1500 

23" 

8" 

OPTIONAL 

2000-2500 

23" 

16" 

STANDARD 

3000-4000 

30" 

18" 

STANDARD 