Spectra UV
Revision D
/
January 2022
Page 20 of 47
Auto Cycle
249B
Auto Cycle is the normal operating mode when the module operates as part of a production
line. In Auto Cycle, the parameters set in Setup mode are used. When there is a board near
the UV lamps, the conveyor moves at the cure speed. The conveyor moves at the transfer
speed at all other times. These speeds are set in Setup mode.
250B
Push the Home icon or “
F3
” at any time to exit Auto Cycle, even when the lamps are in
startup procedure.
All Modes
251B
The options below are available in all modes of Auto Cycle.
1.
68B
The
SMEMA Status Indicators
display the current SMEMA status and the signals
being sent and received. Output from the module is in the box, external signals are
outside the box.
2.
69B
The
Lamp Status Indicators
display each lamp’s individual status.
•
70B
A light on indicates a lamp bulb is on.
•
71B
A light flashing indicates a lamp bulb is preparing to turn on.
•
72B
A light off indicates a lamp bulb is off.
3.
73B
If the
Lamps Cooling Indicator
is flashing, it indicates a lamp bulb is cooling off.
Bulb cooldown time is set in OEM mode.
4.
74B
If the
Bulb Life Expired Indicator
is flashing, it indicates at least one lamp bulb has
reached the warning limit of expected lamp life.
5.
75B
The
Conveyor Width
will display the current conveyor width.
6.
76B
The
Conveyor Speed
will display the current conveyor speed.