SMEMA
210B
For manufacturing lines with conveyor systems, the SMEMA and Intermodule cables must
be correctly connected.
424B
Note: On the diagrams, the J# refers to the label on the machine, not the label on the
cable.
211B
The Surface Mount Equipment Manufacturers Association (SMEMA) Electrical Equipment
Interface Standard is used to make sure the sequence of boards is correct. If these
connections are not in place, boards cannot move from one machine to another. SMEMA
cables have male 14-pin amp-type CPC connectors. The cables are straight-through so
orientation does not matter.
212B
On each module, the wire to the J1 plug must connect to the J2 plug on the machine
upstream. Similarly, the J2 plug on each machine must connect to the J1 plug on the
machine downstream, as shown in the following diagram:
3B
Figure 5: Process Flow