MR2 Manual
Revision B
/
June 2021
Page 7
of
34
Theory of Operation
The MR2 has a dual piston system and can process 2K materials with mix ratios up to 15:1.
For 1K chemistries, the MR2 alternates metering chambers to reduce refill time and increase
throughput. Each metering chamber is controlled independently so the mix ratio and flow
rate can be changed at the application point.
Personal Protective Equipment
Operators must use eye protection because material contents are under pressure. Always
wear gloves when handling materials and solvents. Refer to MSDS sheets on the material
being dispensed for other precautions.
Waste Disposal
Dispose of all used parts and materials in accordance with local laws and regulations.
Necessary Tools
PVA offers tools and cleaning accessories to maintain the MR2.
Part Number
Description
02506
Hook and Pick Set
Soft-jaw Pliers and/or Vice
Lubrication Fluid
Silicone Grease
2.5mm and 3mm T-handle or Hex Key
90° Snap Ring Pliers
Figure 1: MR2 Tool Kit
Spare Parts Kit
Part Number
Description
612-12675-1
Soft Seals (Does not include diaphragm)
614-12157-1
Diaphragm
Figure 2: Spare Parts Kit