Fault Recovery Procedure
226B225B225B
Several errors can cause a fault condition. They are:
•
125B124B124B
The EMERGENCY STOP is engaged or there is an open door
•
126B125B125B
There is an exhaust or intake fan failure
•
127B126B126B
The parameters are out of range
•
128B127B127B
The module is over-temperature
•
129B128B128B
There is a solid-state relay failure
227B226B226B
The following sections show an example of a machine error. For a complete list of error
messages, refer to
Recovery from Emergency Stop or Open Door Error
228B227B227B
If the Emergency Stop button is engaged or the machine has a system error, perform the
following procedure to return the machine to the cycle stop state.
285B284B284B
WARNING: If the Emergency Stop was engaged because of system failure, do not
disengage the Emergency Stop. Shutdown the system and have qualified personnel
repair the machine.
1.
130B129B129B
Disengage the Emergency Stop button or close all doors.
2.
131B130B130B
Select “Clear Fault”.
Recovery from an Exhaust or Intake Fan Failure
1.
132B131B131B
Select “
Clear Fault
” to stop the alarm or “
Reset
” to clear the fault.
2.
133B132B132B
Operate the fan in Manual mode to make sure the components operate correctly.
Recovery from a Parameter Out of Range Error
1.
134B133B133B
Select “
Silence Horn
” to stop the alarm or “
Clear Fault
” to clear the fault.
2.
135B134B134B
Operate the module in manual mode or restart the Auto Cycle. Look for the
parameter that causes the error.
3.
136B135B135B