DeltaTherm IR Cure Module
Revision C
/
September 2022
Page 16 of 41
Machine Safety Check
201B200B200B
When the machine is started, it must initialize. After it has initialized successfully, the
operator interface shows the following screen:
202B201B201B
8B8B8B
Figure 9: PVA Screen
203B202B202B
The machine safety check ensures that the DeltaTherm IR Cure Module safety devices
(emergency stop, door interlocks, etc.) operate correctly. For the startup procedure, the
operator must start and complete the safety check successfully. After you start the safety
check, you must activate and deactivate the safety devices. Some safety checks are timed
and will cause a failure if the action is not done in the set time.
Shutdown Procedure
204B203B203B
Do the following procedure to shut down the cure module.
1.
45B44B44B
Wait for all boards to clear the cure module.
2.
46B45B45B
Press
Auto
Stop
on the OIT. Wait for the PVA screen to appear.
3.
47B46B46B
Wait one minute for the module to cool. The exhaust fan will be on.
4.
48B47B47B
Turn the main power switch to
OFF
.
5.
49B48B48B
Make sure you remove all parts before you shut down the cure module.
273B272B272B
CAUTION: If you plan to perform maintenance during the shutdown, be sure to lock
out and tag the machine.