Technical Manual
RECOMMENDED MAINTENANCE CF
Prefilter PP + CB: 12 months or 3600Lts. *
RO membrane: 36 months or 12000 Lts. *
Postfilter GAC: 12 months or 6000 Lts. *
* Lts. Litres of water produced.
Maintenance must be carried out by trained personnel,
who must handle the equipment properly, as well as
use original spare parts to maintain the characteristics,
warranty, certifications and performance of the equi-
pment and thus preserve the quality of the water dis-
pensed.
ATTENTION: The use of non-original spare parts,
installation outside the limits of operation and
commissioning, improper maintenance or use, may
lead to the loss of the guarantee, as well as the invali-
dation of any kind of quality certifications.
An excess in some compound (total chlorine, turbidity,
hardness, etc ...) can cause a reduction in the life of filters
and certain components. These maintenances are indica-
tive.
The distributor will foresee the duration of the consuma-
bles according to the characteristics of the water to be
treated and the expected consumption in each case.
ATTENTION: All consumables are supplied with
individual packaging specially designed forgua-
rantee hygienic storage and transport conditions.
Exercise extreme precautions after removing the con-
sumables from their packaging and while handling the
various connectors and components.
ATTENTION: Before disassembling the equipment,
provide all the material that you will need to carry
out maintenance operations (read the Table 5 Installa-
tion) and the space required for it. Work in a well-lit
place, in adequate hygienic conditions and with enou-
gh space to carry out operations comfortably.
ATTENTION: To change the filter cartridges, the
equipment must be depressurized beforehand.
To do this, close the inlet valve water to the equipment
and open the dispensing tap for a few seconds until
water hardly comes out and then cuts off the power
supply to the equipment. Once the equipment has been
depressurized, you can change the cartridges.
• Perform filter change properly. Ensure the tightness of
the joints and the original hydraulic configuration of the
system as recommended by the manufacturer.
• Sanitize the equipment following the instructions des-
cribed in the Sanitation Procedure.
• For more information, consult the technical data
sheet of the equipment. If you have any other ques-
tions, consult your dealer.
ATTENTION: Use gloves or appropriate personal
protection measures, if you use chemicals during
sanitization.
Содержание VYRTA direct flow
Страница 1: ...1 USER MANUAL EQUIPMENT REVERSE OSMOSIS ...
Страница 2: ......
Страница 3: ...Index P 1 2 3 4 User manual Technical manual Sanitation procedure Technical Data sheet 4 8 14 19 ...
Страница 13: ...13 IN FEED DRAIN 3 8 1 4 RO 3 8 1 4 1 4 1 4 1 4 Hydraulic scheme ...
Страница 17: ...17 ...
Страница 28: ...NOTES ...
Страница 29: ...NOTES ...
Страница 30: ...NOTES ...
Страница 31: ...NOTES ...
Страница 32: ...MU RO VYRTA DIRECT FLOW 2021 910475 ...