Puretec Sparq S4 Скачать руководство пользователя страница 18

18 

Installation & Operation Manual

Copyright © Puretec Pty Ltd 2021

Warranty

WARRANTY

Any claim under this warranty must be made within 1 year of the date of purchase of the 
product. This product is warranted to be free of defect of material and workmanship for 
1 year from date of purchase. To make a claim under the warranty, take the product and 
proof of purchase to place where you purchased the product, and they will lodge a Warranty 
Request with Puretec. 1 year warranty is parts and labour. Excludes cartridges and canisters. 

Puretec will pay your reasonable, direct expenses of claiming under this warranty.  You may 
submit details and proof of your expense claim to place of purchase for consideration.

The warranty only applies if the product was used and/or installed in accordance with the 
user guide and/or installation instructions. This warranty is given in lieu of all other express 
or implied warranties and manufacturer shall in no circumstance be held liable for damages 
consequential or otherwise or delays caused or faulty manufacturing except as excluded by 
law.

Applicable to all above, is that the warranties need to be approved by Puretec to ensure 
product was not incorrectly used, installed or claimed. False and incorrect claims will be 
pursued at Puretec’s discretion, including chargeable inspection and labour costs incurred.

WARRANTY / AUSTRALIA

This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road Lonsdale 
SA 5160, telephone no. 1300 140 140 and email at [email protected].

This warranty is provided in addition to other rights and remedies you have under law: Our 
goods come with guarantees which cannot be excluded under the Australian Consumer Law.  
You are entitled to replacement or refund for a major failure and to compensation for other 
reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 
replaced if the goods fail to be of acceptable quality and the failure does not amount to a 
major failure. 

WARRANTY / NEW ZEALAND

This warranty is given by Puretec Ltd, Reg. No 4464398, PO Box 875, Cambridge 3450, NZ, 

telephone no. 0800 130 140 and email at [email protected].

This warranty is provided in addition to other rights and remedies you have under law: Our 
goods come with guarantees which cannot be excluded under the Consumer Guarantees Act.  
You are entitled to replacement or refund for a major failure and to compensation for other 
reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 
replaced if the goods fail to be of acceptable quality and the failure does not amount to a 
major failure. 

Содержание Sparq S4

Страница 1: ...g Chilled Ambient Water Filter System For correct operation installation it is essential to observe these instructions MAR2021 SODA COLD CHILLING WMTS 105 Certificate No 23291 Australian Certification...

Страница 2: ...Customer Service 3 Installation Record 3 Before Installation 4 Parts Included 5 Specifications 5 Figure 1 Dimensions 6 Figure 2 Tap Button Identification 7 Figure 3 CO Bottle 7 Figure 4 Exploded Diagr...

Страница 3: ...litan supply water only Flush the system for 5 minutes or more after any period of non use more than 2 weeks Note Where maximum line pressure exceeds 500 kPa the supplied multivalve pressure limiting...

Страница 4: ...power and water connections Check there is sufficient room for the appliance inclusive of ventilation requirements within the cupboard and that the cupboard is capable of supporting the appliance with...

Страница 5: ...LD CHILLING Model SPARQ S4 Flow 20 Lph Chilled Temperature 4 C to 10 C Power Requirements 50Hz 220 240 V Max Power Consumption 100 W Tap Dimensions 423 H x 205 mm W Appliance Dimensions 390 H x 81 W x...

Страница 6: ...ion Manual Copyright Puretec Pty Ltd 2021 System Identification A 26mm hole is required for faucet Max 30mm Warranty cover parts and labour for the period of 1 year where applicable subject to approva...

Страница 7: ...2021 Puretec Sparq S4 User Guide System Identification CO2 Bottle Figure 2 Tap Button Identification Cold Sparkling Ambient Figure 3 CO2 Bottle Pressure Regulator CO2 Tube Black Pressure Gauge Pressu...

Страница 8: ...1 Figure 4 Exploded Diagram Note All lines are 1 4 tube Water Inlet Connection Blue Multivalve Pressure Limiting Valve Water Outlet White CO2 Tube Black Straight Connector Unit Power Supply Wiring Loo...

Страница 9: ...Fitting grips before it seals Ensure tube is pushed in to tube stop Figure 5 How To Use Quick Connect Fittings 3 Tube is secured in position How To Operate The Tap When the blue light is on the tap i...

Страница 10: ...sh the collet against the quick connect nut and slide tube out of fitting 3 The fitting grips before it seals Ensure the tube is pushed all the way into the tube stop 4 Once the tube is secured in pos...

Страница 11: ...may split the plastic nut Note For thin bench tops or a sink mount use the supplied spacer slipping it up the thread followed by the black nut to tighten 8 Choose the best position for the unit with...

Страница 12: ...RQ CO2 is NOT refillable 14 Ensure the regulator is in the off position by turning the black knob fully counter clockwise until home see Fig 3 15 Connect the CO2 bottle to the regulator by screwing th...

Страница 13: ...ature is preset to 4 10 degrees within the tank It takes approx 20 30 minutes to complete its chill cycle dependent on incoming water temperature and ambient surrounds of the unit Soda Sparking Water...

Страница 14: ...operation 33 Allow 1 2 hours for the water to both chill and reach full carbonation Note A small amount of water will come out after using the sparkling feature for 1 2 seconds This is normal as the...

Страница 15: ...by pushing up and rotating in a anti clockwise direction until it stops 7 Reinsert the manifold ensuring it clicks in securely 8 Restore the water supply SmartTee valve checking that there are no wate...

Страница 16: ...for leaks Note Some CO2 will escape as the valve in the bottle is depressed 4 Slowly open the CO2 regulator by turning the black knob clockwise until the gauge reads 3 Bar 5 Operate the sparkling but...

Страница 17: ...provider No cold water from tap Ice blockage Please turn off the power supply and allow 24 hrs for the blockage to melt No water inside the cold water tank Please check mains water supply Soda not wor...

Страница 18: ...or claimed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred WARRANTY AUSTRALIA This warranty is given by Puretec Pty Ltd ABN...

Страница 19: ...19 Copyright Puretec Pty Ltd 2021 Puretec Sparq S4 User Guide...

Страница 20: ...tridges Important Note Sales of products are subject to our Terms and Conditions which are available upon request All specifications information and photos are a guide only and are subject to change w...

Отзывы: