9
Undersink UV Filter System with Tripla
™ LED
Mixer Tap
Mixer Tap Servicing
Mixer Tap Servicing
Periodically clean the aerator for any lodged sediment that may restrict flow. A Puretec water
filter is highly recommended on all incoming lines for product longevity.
Should it be necessary to have your mixer serviced while under warranty, please carry out the
following procedure:
1.
Firstly call the plumber, preferably the one that has installed it, (most problems are
caused by the supply lines not being cleaned out properly, prior to connecting the
mixers).
2.
Make sure that the plumber has installed your mixer according to the Instruction Guide.
3.
If the plumber is satisfied that he cannot rectify the problem then contact your
plumbing supply store or your local Puretec stockist.
Important
: We do not recommend the dismantling of any internal part of the mixer
as this will breach your warranty.
Replacement of Ceramic Disc Cartridge(s)
1.
Hot/Cold Outlet
• Remove hot and cold water indicator then release screw in lever and lift lever off, now
you can unscrew dome cap and loosen the cartridge lock nut.
• Lift out old cartridge and clean inside making sure no old O-rings are still stuck inside
cartridge housing.
• Insert new cartridge making sure O-rings on bottom of new cartridge have not fallen
off and lugs in bottom of cartridge line up with holes in cartridge housing.
• Now you can tighten lock nut with a torque wrench to 14 newton meters, then reinstall
dome cap, lever screw and hot and cold water indicator.
2.
Filtered/Rain Ancillary Outlet
• Remove front button cover using fine-edged 1.2mm screwdriver.
• Unscrew handle then remove cartridge by unscrewing it anti-clockwise, using 5/8”
socket. Install cartridge by completing removal instructions as above, in reverse order.
• Ensure cartridge is firmly tightened not over tightened.
Содержание ESR2 Series