Содержание ESR2 Series

Страница 1: ...3497 Licence No WM 74617 Australian Certification Services JAN2021 User Guide Undersink UV Filter System with Tripla LED Mixer Tap ESR2 Tripla Series DO NOT OVERTIGHTEN DO NOT USE LIQUID SEALANTS SUR...

Страница 2: ...ption 17 Tripla T2 Parts Description 18 Tripla T3 Parts Description 19 Tripla T4 Parts Description 20 Tripla T5 Parts Description 21 Tripla T6 Parts Description 22 Warranty 23 Puretec Customer Service...

Страница 3: ...acid base cleaning agents be used Installation Note A water filter system tap like any product has a limited life and may eventually fail Also sometimes failure happens early due to unforeseen circums...

Страница 4: ...r Rubber Washer Locking Nut Retainer Screw Metal Pipe Fig 1 Mixer Tap Installation Guide PART 1 Mixer Tap Assembly Installation Note It is important to flush out the supply pipes to the mixer before c...

Страница 5: ...Spacer Locking Nut Retainer Screw Zinc Spacer Fig 2 Tap Assembly O Ring Brass Base 1 2 Step 1 Connect the hoses to the faucet and tighten them Refer to page 7 for connection patterns Only use hand to...

Страница 6: ...ation Operation Manual Copyright Puretec Pty Ltd 2021 Retainer Screw HOT Water Connection COLD Water Connection Water Filter Connection For ESR2 T1 ESR2 T2 Fig 3 Water Connection Patterns Mixer Tap Co...

Страница 7: ...Filter System with Tripla LED Mixer Tap Mixer Tap Connections Retainer Screw HOT Water Connection COLD Water Connection Water Filter Connection For ESR2 T3 to ESR2 T6 Retainer Screw Fig 4 Water Conne...

Страница 8: ...the faucet canopy Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes or 12 months Ple...

Страница 9: ...e dismantling of any internal part of the mixer as this will breach your warranty Replacement of Ceramic Disc Cartridge s 1 Hot Cold Outlet Remove hot and cold water indicator then release screw in le...

Страница 10: ...d ensuring it is surge protected If in doubt please consult a qualified electrician Where the water being treated contains unusually high levels of dissolved solids particularly hard water iron mangan...

Страница 11: ...see Fig 7 SmartTee Quick Connect Fitting Allow slack in tubing Replacement Guide Install the filter housing assembly by positioning it in the desired location marking the position of fixing holes and...

Страница 12: ...ixings are required to go you may need to unclip and remove the lamp chamber to do so 12 Drill the holes and install the anchors fixing anchors not included 13 Position the ESR2 unit on the wall Inser...

Страница 13: ...to tube stop 3 Tube is secured in position Fig 6 How To Use Quick Connect Fittings Fig 5 Installation Diagram No DESCRIPTION 1 Tripla Mixer Tap 2 Lock Nut Washer 3 Filtered Water Flexible Hose Plain...

Страница 14: ...the quick connect nut and slide tube out of fitting 3 The fitting grips before it seals Ensure the tube is pushed all the way into the tube stop 4 Once the tube is secured in position turn the quick...

Страница 15: ...he unit in case of drips 3 Slowly pull the black the black lamp cap off being careful not to detach the lamp inside Do not use a twisting motion as this will unscrew the aluminium nut underneath simpl...

Страница 16: ...sleeve regularly about every 3 months depending on quality of water source To see whether there is dirt or substances gathered Follow maintenance Quartz Sleeve Maintenance Procedure below Quartz Sleev...

Страница 17: ...Aerator Insert 32 Aerator Insert 30 Aerator Cap 33 Aerator Cap 16 Rubber Washer 15 2 Nut 19 Rubber Washer 20 Stainless Washer 21 Brass Nut 18 Screw 35 Screw 39 Display 9 Cover Stem 7 Plunger 11 Spout...

Страница 18: ...Screw 36 Display 32 Screw 31 Plunger 33 Magnet Seat 34 Strong Magnet 35 Handle Cap 7 Cover Stem 12 Body Stem 38 O Ring 41 Battery Seat 40 Circuit Board 5 Plunger 9 Spout 2 Cap 4 Cap 6 Stem Cartridge 1...

Страница 19: ...t 8 Screw 40 Screw 26 O Ring 23 Spout 28 Body 35 Body 36 Nut 23 3 Inner Tube 23 2 Tube 11 Screw 24 Cap 1 W asher 2 Aerator Insert 3 Aerator Cap 23 1 Body 27 O Ring 29 O Ring 30 Connector 30 2 Cartridg...

Страница 20: ...6 Screw 37 Handle Cap 29 Body 38 1 Body 38 2 Nut 30 O Ring 31 Connector 32 Stem 33 Plunger 34 Cap 39 Stopper 40 Washer 17 Circuit Board 10 Cap 13 Display 16 Screw 11 O R ing 12 Screw 15 Washer 21 Plun...

Страница 21: ...p 29 Body 38 1 Body 38 2 Nut 30 O Ring 31 Connector 32 Stem 33 Plunger 34 Cap 39 Stopper 40 Washer 17 Circuit Board 10 Cap 13 Display 16 Screw 11 O Ring 12 Screw 15 Washer 21 Plunger 22 Turn Stem Body...

Страница 22: ...40 Handle Cap 32 Body 41 Body 41 1 Nut 33 O Ring 34 Connector 35 Stem 36 Plunger 37 Cap 42 Stopper 43 Washer 20 Circuit Board 13 Cap 16 Display 19 Screw 14 O Ring 15 Screw 18 Washer 24 Plunger 25 Tur...

Страница 23: ...ntial or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the warranties need to be approved by Puretec to ensure product was not incorrectl...