INSTALLER: LEAVE THIS MANUAL WITH THE OWNER

IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING
INSTRUCTIONS.

READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN

SERIOUS OR FATAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.  THIS PRODUCT
MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL.  FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND
REGULATIONS. IN THE ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND
OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF
PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as
listed in Clinical Toxicology of Commercial Products, 5th edition. The pressure of the heat transfer

medium must be limited to 30 PSIG by an approved safety or relief valve.

INSTALLATION, OPERATION

& MAINTENANCE

INSTRUCTIONS

Part #: 9040-658 (9/06)

PLUG N’ GO and PIPE N’ GO

INDIRECT-FIRED WATER HEATERS

MODELS COVERED:

PLUG N’ GO PRO-41ZPG, PRO-80ZPG
PIPE N’ GO TD-41ZPGLP, TD-80ZPGLP

 

Содержание PIPE N' GOTD-41ZPGLP

Страница 1: ...F THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE AS APPLICABLE THIS IS THE SAFETY ALERT SYMBOL IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS OBEY ALL SAFETY MESSAGES TH...

Страница 2: ...heater will be supplied just as another zone This means that if all space heating zones call for hot boiler water at the same time the water heater may not be supplied with enough hot boiler water to...

Страница 3: ...e the existing diaphragm expansion tank 3 REQUIRED COMPONENTS AND ACCESSORIES CHECKLIST SHUTOFF VACUUM RELIEF THERMAL EXPANSION MODEL CIRCULATOR ZONE VALVE VALVE BREAKER VALVE TANK DRAIN PRO 41ZPG Inc...

Страница 4: ...bing code BOILER PIPING 1 Plumb the BOILER SUPPLY line The circulator and flow check are factory installed 2 Pipe the BOILER RETURN connection to the boiler return line Be sure the return line is NOT...

Страница 5: ...Thermal Expansion Tank PIPING MODELS WITH PRE INSTALLED CIRCULATOR W INTEGRAL FLOW CHECK 5...

Страница 6: ...ed directly to the threaded pipe marked BOILER SUPPLY Alternately the circulator can be placed anywhere on the boiler supply line 2 Pipe the BOILER RETURN connection to the boiler return line Be sure...

Страница 7: ...Thermal Expansion Tank PIPING USING SEPARATE CIRCULATOR PUMP RECOMMENDED Thermal Expansion Tank PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR 7...

Страница 8: ...he unit Ensure that the proper conduit and connections are used per your local code In lieu of local code the National Electric Code should be followed DHW AQUASTAT FACTORY WIRED LINE OUT CANCELS ON C...

Страница 9: ...LIVE NEUT PR OUT PR IN 1 2 3 4 L1 L2 Indirect Aquastat L1 L2 B2 B HONEYWELL L8148J W MILLIVOLT GAS VALVE WHITE RODGERS 8J48A W 24V GAS VALVE CIRCULATOR RELAY BOX Indirect Aquastat L2 LIVE NEUT PR OUT...

Страница 10: ...al Control models select the appropriate diagram from the following pages Always disconnect power before wiring the control Ensure that the proper conduit and connectors are used per your local code I...

Страница 11: ...X Boiler Aquastat Zone Outputs Priority or DHW Zone Thermostat Inputs Typical Multi Zone Relay Circulator Aquastat AQUASTAT AQUASTAT ZONE VALVES SCHEMATIC 3 PRIORITY W CIRCULATORS SCHEMATIC 4 3 WIRE...

Страница 12: ...12 AQUASTAT BOILER CONTROL SCHEMATIC 5 HONEYWELL L8148E...

Страница 13: ...considered normal and will clear as hot water is used 3 START HEATER Turn power on to the unit The knob should be rotated to the 120 F mark The circulator and boiler should start momentarily If not ch...

Страница 14: ...plumbing 2 Reduce temperature setting 3 Re insert temperature sensor 4 Repair or replace 5 Clean repair or replace Noise from water heater 1 Air in boiler loop 2 Faulty circulator pump 3 Thermal expa...

Страница 15: ...eries Heat Exchanger w Gasket and Nuts Pump not included 41 Gallon 2700 5007 41 Gallon 2700 5007 80 Gallon 2700 5009 80 Gallon 2700 500 Flange Gasket Only 2704 403 2704 403 Aquastat Well Assembly 2700...

Страница 16: ...ter heater must be electrically grounded Electrical supply must come from the boiler side of boiler s emergency shut off switch in order to prevent unsafe boiler operation Chlorine Aggressive Water Th...

Страница 17: ...ns ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED Limitations of Remedies THE REMEDIES CONTAINED IN THIS WA...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...20 Part 9040 658 9 06...