PUREAIR AIR PURIFICATION SYSTEM
PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY
INSTALLATION INSTRUCTIONS FOR PUREAIR AIR PURIFICATION SYSTEM
MODELS PCO14-23, PCO16-28 AND PCO20-28
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Shipping & Packing List
Assembled PureAir air purification system which
includes:
1 - Cabinet
1 - Control box assembly (includes frame, ballasts
and associated wiring)
1 - MERV 16 pleated filter
2 - UVA lamps (taped to the cabinet and the insert foil
packaging)
1 - Titanium dioxide PureAir Insert
1 - Power cord (120VAC)*
*230VAC power cord available separately (part number
91X44).
A warranty certificate and registration card are also
included.
Shipping Damage
Check equipment for shipping damage. If damage is
found, immediately contact last carrier.
General Information
The PureAir air purification system uses photocatalytic
oxidation (PCO) technology to significantly reduce levels
of airborne volatile organic compounds, cooking odors,
common household odors, airborne dust particles, mold
spores and pollen. The PureAir system is available in
three models: PCO14-23, PCO16-28 and PCO20-28.
Each unit may be connected to either 120VAC or 230VAC
power supply. If 230VAC power supply is used, a 230VAC
power cord must be ordered separately.
Lab tests confirm a 50% reduction in total volatile organic
compounds (TVOC) within the first 24 hours of initial
operation of the PureAir air purification system. It may
take up to 48 hours after initial system start-up to reduce
the airborne chemicals that have built up in a home over a
long period of time.
For peak performance, unit should be installed in homes
with TVOC levels that are less than 1000 micro-gram /
cubic meter. Home source removal and ventilation may be
required to lower TVOCs to this level.
NOTICE
This system is NOT intended to be used for removal
of active mold growth or continuous sources of
high levels of chemicals in the air.
For existing mold growth, the mold must be proper
ly removed PRIOR to installation of the PureAir air
purification system.
WARNING
Risk of property damage, injury, or death.
Installation and service must be performed by a
qualified installer or service agency.
WARNING
Electric shock hazard.
Can cause injury or death.
Disconnect all electrical power supplies before ser
vicing. Access panels must be in place during ap
pliance operation.
CAUTION
Sharp edges hazard.
Sharp edges can cause injuries.
Use protective gloves when grasping equipment
edges.
NOTICE
Possible odor emissions. Chemical reactions may
cause temporary odors after initial start-up or after
lamp replacement. Odor may also be present after
paint, cleaning solutions or hobby materials have
been used in the conditioned space.
Some occupants may experience irritation or dis
comfort during this period. If the irritation or dis
comfort lasts longer than 48 hours, the homeowner
should be advised to contact a Lennox dealer.
Unique Field-Supplied Installation Items
Cotton gloves and cloth (to remove finger prints from
lamps)
Aluminum foil tape or water-based mastic (NOT
silicone) to be applied as a sealant.