General information

Directives

This device was constructed in accordance with the fol-
lowing directives:
• See the EC Declaration of Conformity included.

Export

We emphasize that these devices are intended for the Eu-
ropean market only and must not be exported to the USA 
or Canada and operated in those countries! The manufac-
turer does not accept any liability in the event of non-com-
pliance! We explicitly emphasize that non-observance of 
this instruction may result in high liability risks for the ex-
porter and/or operator.

Environmental protection

Environmental regulations – disposal of lamps 
and batteries

UV lamps contain fluorescent materials and other waste 
products containing mercury. Batteries contain heavy 
metal compounds.
Within the European Union the national implementation of 
the Waste Framework Directive 2018/851/EC applies. Ac-
cording to the national waste disposal laws and in accord-
ance with the municipal waste regulations, proof must be 
provided of the proper disposal of lamps and batteries. 
The JK International GmbH Customer Service depart-
ment will be happy to assist you with the disposal of lamps 
and batteries:
– Report the number of lamps and batteries to the Cus-

tomer Service department by telephone or in writing.

The Customer Service department will provide you with 
the name of a free delivery point for your lamps or will 
handle the collection and proper disposal of the lamps in 
cooperation with a disposal company. This service is 
available for a fee. 
Local national laws apply outside Germany. Please con-
tact JK-International GmbH Customer Service.

Packaging

All packaging consists of 100% recyclable materials. 
Packaging brought into circulation by the JK Corporate 
Group that is no longer required can be returned to the JK 
Corporate Group. Your Customer Service or dealer will be 
happy to advise you.

Disposal of Old Devices

The device has been manufactured using recyclable ma-
terials. The JK Corporate Group will provide you with in-
formation on the content or potential hazards of the 
materials used.
In accordance with the 2012/19/EU directive, 
implemented in Germany in the Electrical 
and Electronic Equipment Act (ElektroG), 
the manufacturer is obliged to take back and 
dispose of certain electrical and electronic 
components. The components and devices are labelled 
with the following symbol:
On request, this device will be disposed of correctly by the 
JK Corporate Group

1)

. This service is available free of 

charge. JK-International GmbH Customer Service will be 
happy to advise you.

Registration numbers

Companies within the JK Corporate Group are registered 
as manufacturers in Germany and assume all obligations 
in connection with the German Electrical and Electronic 
Equipment Act.
Registry number JK-International GmbH, JK-Licht divi-
sion (lamps):
WEEE-DE 61515020
Registry number JK-Products GmbH (devices):
WEEE-DE 62655951

Warranty

JK-International GmbH accepts liability for any defects to 
the equipment that arise in accordance with the following 
regulations on behalf of customers who have purchased 
a room air degerminator for private or commercial utilisa-
tion; wear parts such as UV-C lamps and the reflector are 
not covered by the warranty.
Should the product contain faults, JK-International GmbH 
is entitled and obligated to repair or replace the product at 
its own discretion. Where it is not possible to repair or re-
place the product, the customer may withdraw from the 
purchase agreement or reduce the purchase price by a 
suitable amount.
The warranty period is one year from delivery or from ac-
ceptance, if an acceptance process is required.
This does not affect the rights of the customer under the 
existing warranty with regard to any claims that the cus-
tomer might have in accordance with the contract of pur-
chase.

1)

The respective national laws apply. Please contact 
your local dealer.

Содержание STERIBASE 300

Страница 1: ...Operating instructions EC Declaration of Conformity pure STERIBASE 300...

Страница 2: ......

Страница 3: ...1025009 00 en 07 2020 07 Operating instructions Translation of the original operating instructions pure STERIBASE 300 100003739...

Страница 4: ...22 24 818 205 E mail service jk globalservice de Spare part orders for consumables JK INTERNATIONAL GmbH Division JK Licht K hlershohner Stra e 60 53578 Windhagen GERMANY Tel 49 0 22 24 818 600 Fax 4...

Страница 5: ...Export 10 Environmental protection 10 Warranty 10 Warranty and liability exclusions 11 Description 12 Scope of delivery 12 Description of device 13 Installation and operation 14 Identification on the...

Страница 6: ...nd viruses in the air conducted through it Any other use shall be considered improper The manu facturer cannot be held liable for damage or injuries re sulting from improper use The operator alone bea...

Страница 7: ...ut any maintenance work and before opening the device NeveroperateUV Clampsoutsidethedevice or when it is open DANGER Risk of eye and skin damage due to UV C ra diation Connection to the mains can be...

Страница 8: ...scape Please adhere to the prescribed maintenance inter vals This device may be used by children over the age of 8 persons with reduced physical sensory or mental ca pabilities and persons who have li...

Страница 9: ...con tact with glass or mercury powder using a damp paper towel Any paper towels and adhesive tape used during the cleaning process should be placed in the container with the broken lamp Dispose of th...

Страница 10: ...itube basic IP 100001429 40324 1 40324 2 Stackability on a pallet Keep dry Weight including packaging This way up Permitted temperature during transport and storage Centre of gravity CAUTION Device ma...

Страница 11: ...he inside and outside as well as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree...

Страница 12: ...ice or dealer will be happy to advise you Disposal of Old Devices The device has been manufactured using recyclable ma terials The JK Corporate Group will provide you with in formation on the content...

Страница 13: ...nd protective equipment including warning signs continued operation 10 years after date of manufacture without condition assessment by a certified JK International GmbH service technician not complyin...

Страница 14: ...2020 Description Description Scope of delivery 40326 4 1 11 3 2 4 Scope of delivery 2 100003739 pure STERIBASE 300 1 1024949 Operating instructions 3 1503309 Mains power cable 2 5 m b 1007345 Service...

Страница 15: ...and air outlet 2 Control panel 3 STERITUBE PLUS with 2 UV C lamps 4 Pedestal with fan 5 Air inlet filter three part 6 Mains connection with On Off switch 7 Type plate 8 Warning label 9 Maintenance st...

Страница 16: ...he model type and device no a can be found 1 In Germany VDE regulations DANGER Personal danger due to electric shock or burns Assemblyandelectricalconnectionmustcomply with the national regulations 1...

Страница 17: ...chsanweisung 15 24 Installation and operation Setting up the floor standing device Note Please observe the notes on installation and operation on p 6 40329 1 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4056...

Страница 18: ...00 1025009 00 07 2020 Installation and operation Setting up the floor standing device 230 240 V 40350 1 6 Note If the mains switch is switched on the device starts with the lamps switched off Position...

Страница 19: ...anweisung 17 24 Installation and operation Moving the floor standing device Note Please observe the notes on installation and operation on p 6 230 240 V 40562 0 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4...

Страница 20: ...18 24 pure STERIBASE 300 1025009 00 07 2020 Installation and operation Moving the floor standing device 230 240 V 40350 1 6...

Страница 21: ...1025009 00 07 2020 Installation and operation Switching the device on Switching the device off If the mains switch is switched on the de vice starts with the lamps switched off Po sition 0 230 240 V 4...

Страница 22: ...device off Rectify the fault if possible e g clean the filter clear any covered openings check the mains plug and On Off switch Switch the device on If the red LED continues to light up please call Cu...

Страница 23: ...l as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree of soiling Moist cleaning f...

Страница 24: ...tem connecting cable supplied loose H 1640 mm B 600 mm D 550 mm T1 500 mm H T1 T B 40353 2 Mains connection The scope of delivery includes a power cable with protective earth plug CEE 7 7 The followin...

Страница 25: ...230 m h Level 3 300 m h Sound pressure level measurement LpA Level 1 29 4 dB A Level 2 40 5 dB A Level 3 47 2 dB A Sound power measurement LwA Level 1 39 6 dB A Level 2 51 2 dB A Level 3 58 0 dB A Env...

Страница 26: ...24 24 pure STERIBASE 300 1025009 00 07 2020 EC Declaration of Conformity EC Declaration of Conformity...

Страница 27: ......

Страница 28: ...1025009 JK INTERNATIONAL GMBH K hlershohner Stra e 60 53578 Windhagen Tel 49 0 22 24 818 600 www pure lufthygiene de info pure lufthygiene de pure jk group net...