DRIVE PURE OXYGEN CONCENTRATOR  MODELS CH5000S and CH5000

.......................................................................................................................

10

Symbol Key

Description

Warning, Consult Accompanying Documents

Follow Instructions for Use

Manufacturer

Degree of Protection Against Electrical Shock: Type BF Unit

Class II Equipment

Do Not Dispose of in Household Waste

No Smoking

No Oil or Grease

Prescription Only

Do Not Disassemble

Serial Number

Drip Proof Equipment

SN

ONLY

Separation Distances

Recommended separation distances between portable and mobile 

RF Communications equipment and the Pure Oxygen Concentrator

The Pure Oxygen Concentrator is intended for use in the electromagnetic environment in 
which radiated RF disturbances are controlled. The customer or user of the Pure Oxygen 
Concentrator can help prevent electromagnetic interference by maintaining a minimum 
distance between portable and mobile RF communications (transmitters) and the Pure 
Oxygen Concentrator as recommended below. According to the maximum output power 
of the communication equipment.

  

 

 

     Separation distance according to transmission frequency in meters

   

Max Output Power

      150 kHz to 80 MHz      80 MHz to 800 MHz 

800 MHz to 2.5 GHz

  

(Watts)

 

D = (3.5/V

1

)(PP) D=(3.5/V

1

)(PP) D=(7/V

1

)(PP)

 0.01 

0.12 

0.12 

0.23

 0.1 

0.37 

0.37 

0.74

 

 1 

1.17 

1.17 

2.33

 10 

3.69 

3.69 

7.38

 100 

11.67 

11.67 

23.33

This equipment has been tested and is in compliance with the EMC limits specified in IEC/
EN 60601-1-2. These limits are designed to provide a reasonable protection against harmful 
interference in a residential installation. If you do experience interference from other equip-
ment you may try to correct or reduce the interference by one of the following measures:
 

·  Reposition, relocate, or increase the separation distance between the equipment

 

·  Connect the equipment into an outlet on a circuit that is different from that to which  

 

  the other device is connected

IP21

Содержание CH5000

Страница 1: ...Product Information and User Instructions Models CH5000S and CH5000 Caution This device is only to be used by or on the prescription of a physician...

Страница 2: ...ning Introduction to Your Pure Oxygen Concentrator The Pure Oxygen Concentrator is designed as a stationary supplemental oxygen source A physician has prescribed supplemental oxygen because you are no...

Страница 3: ...s of the concentrator Rear View Figure B 7 Ventilation Slots 8 Humidifier bottle holder 9 Connection Adapter for humidifier bottle 10 Humidifier Bottle not included 11 Filter Door NORMAL OXYGEN ALARM...

Страница 4: ...of a physician or healthcare provider Oxygen supplied by this device should not be considered life supporting or life sustaining For those individuals who a healthcare professional has determined int...

Страница 5: ...the Oxygen Outlet Barb Figure D 5 Fill the humidifier bottle with distilled water 6 Using the strap firmly secure the humidifier bottle to the concentrator Figure E 7 Run the Connection Adapter under...

Страница 6: ...oximately every 12 months or as needed Please contact your equipment provider for a replacement Cannula Tubing and Humidifier Bottles Clean and replace as recommended and directed by the manufacturer...

Страница 7: ...unit has lost the power connection and the switch is in the on position See section A of the troubleshooting section of this manual Intermittent Beep No power to Unit See section A of the trouble sho...

Страница 8: ...in back are blocked Check the rear cooling vents are not blocked or restricted If unit ceases to alarm after a minimum of two minutes and proper flow appears to have returned this was the issue 3 Blo...

Страница 9: ...ws ranging 0 5 to 5 LPM Outlet Pressure 5 5 PSI 0 5 PSI Flow Range 0 5 to 5 LPM Low Flow Alarm 0 5 LPM Pressure Relief 35 PSI 5 PSI 247kPa 35 kPa Change in Maximum Recommended Flow when Back Pressure...

Страница 10: ...rtable and mobile RF communications transmitters and the Pure Oxygen Concentrator as recommended below According to the maximum output power of the communication equipment Separation distance accordin...

Страница 11: ...than a Drive Medical Authorized Service Professional shall immediately void this warranty Drive Medical will not accept damages or charges for labor parts or expenses incurred in making field repairs...

Страница 12: ...Drive Medical 99 Seaview Blvd Port Washington NY 11050 Toll free 877 224 0946 www drivemedical com...

Отзывы: