Whisper 30 Modular Handbook
4.2 Preparations for Installation
For installation pay attention to the Flow Diagram on Page 19
Sea Water Filter (Strainer)
Place the Strainer direct after the Sea Cock. The Strainer has a 50µ washable Filter inside.
At the Strainer is the
Selector Valve
mounted. Here you can select either Sea Water operation or Fresh Water
Operation. The lower connection is for Sea Water, the upper connection is for the line from the Carbon Filter
(FWF System) or, if installed from the Selector Valve 1 if a Clean/Rinse Kit is installed.
Vane Pump. (Feed Pump)
The outlet of the Strainer has to be connected to the inlet of the vane pump.
Install the Vane Pump at or better below the waterline.
For the first use, fill the Vane pump with water.
Pre-Filter
The Pre-Filter can be installed above the waterline.
Product Water connection
The product water can be picked up at the top of the flow meter. There is an 8mm hose connection. Connect this
to the sample valve at the 5” post carbon filter. This is the lower hose barb. The hose barb at the right is the
sample line.
7