Pure Blue H20, LLC
13813 Monroes Business ParkTampa, FL 33635 USA
www.pureblueh2o.com (844) 787-3148 • (844) PURE-1-4-U
2015.06.30 #8739 PAW
REVERSE OSMOSIS
WATER FILTRATION SYSTEM
MODEL PB-TLRO4H50T
INSTRUCTION MANUAL
Страница 1: ...Blue H20 LLC 13813 Monroes Business Park Tampa FL 33635 USA www pureblueh2o com 844 787 3148 844 PURE 1 4 U 2015 06 30 8739 PAW REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL PB TLRO4H50T INSTRUCTION M...
Страница 2: ...allon Hardness Recommended hardness not to exceed 10 grains per gallon or 170 parts per million Note System will operate with hardness over 10 grains but the membrane life may be shortened The additio...
Страница 3: ...Flow REQUIRED TOOLS MATERIALS Tape Measure 1 8 1 4 Drill Bits Phillips Head Screwdriver Pencil Adjustable Wrench Safety Glasses Utility Knife Drill Pan or Bucket PACKAGE CONTENTS 2 2...
Страница 4: ...location susceptible to freezing INSTALLATION OVERVIEW There are seven easy steps to installing your RO unit They are as follows Step 1 Install Angle Stop Adapter water source for lter system Step 2...
Страница 5: ...rical appliances and outlets are turned off at the circuit breaker before working in the cabinet area STEP TWO INSTALL RO DRAIN CONNECTOR 1 Identify drain outlet location 2 Knock out center hole on fo...
Страница 6: ...toward the back of the Filter System and the two extended anges should be out to each side Note PartNo PB TLRO4SEDT Sediment shouldbeinstage1 PartNo PB TLRO4CB2T Pre Carbon shouldbeinstage2 PartNo PB...
Страница 7: ...e down shank and split washer to slide out and set it aside see faucet drawing in gure 1A on right 4 Route 3 tubes on faucet from top of sink through hole in sink Make sure all tubing is inserted thro...
Страница 8: ...e manifold INLET approximately 5 8 until it stops Note It is not necessary to remove tubing for routine maintenance and filter exchanges however it may easily be disconnected if necessary To disconnec...
Страница 9: ...te 2 By pushing down on the white collar while pulling plug with other hand remove plug from membrane filter drain port 3 Identify 1 4 red tubing attached to faucet body 4 Identify length necessary to...
Страница 10: ...l the 1 4 red tubing from the faucet body 2 Determine if tubing is long enough to reach drain If yes insert restrictor in end of tubing and insert this end into drain port on membrane lter If no repla...
Страница 11: ...ter System is first pressurized water may project from faucet air gap hole until air is passed from RO Filter System Purge 1 Open the RO faucet and leave it open until water begins to trickle out this...
Страница 12: ...h the EPA s website at www epa gov sfaewater arsenic html There are two forms of arsenic pentavalent arsenic As V and trivalent arsenic As III Special sampling procedures are needed for a lab to deter...
Страница 13: ...y 3 factors 1 Incoming water temperature 2 Total dissolved solids TDS present in supply water 3 Incoming water pressure Lower temperatures are directly proportional to slower ow rate All membranes are...
Страница 14: ...lter 2 Hold new lter with label facing a quarter turn to the left The two nozzles on top of lter should be toward the back of the Filter System and the two extended anges should be out to each side 3...
Страница 15: ...months Stage 3 every 2 5 years and Stage 4 annually or more frequently depending on incoming water conditions Failure to do so may cause damage to the system which will void warranty coverage WE MAKE...
Страница 16: ...Pure Blue H20 LLC 13813 Monroes Business Park Tampa FL 33635 USA www pureblueh2o com 844 787 3148 844 PURE 1 4 U...