Maintenance:
Cleaning the Metering Jet and Screen
Rarely does the metering jet itself get plugged. However, the protective mesh screen may
build up debris or large particles that could impede oil flow over time
.
IMPORTANT
:
When the engine or equipment is turned off.
Carefully remove the supply
hose from each supply fitting (residual oil may still be present in fittings, bypass system or
hose). Blow out the oil supply hose with high air pressure before proceeding to refastening
supply hose.
Failure to do so will result in hose, screen or metering jet becoming clogged
again.
Canister and Metering Jet Dis-Assembly
1. Loosen and remove supply fitting on the bottom of the MTS unit.
2. Carefully remove metering jet screen from the supply port (use caution to avoid
damaging port threads).
3. Using a Hex Drive remove the metering jet.
4. Reinstall in reverse order from Step 3.
Metering Jet
Metering jet screen
Bottom of MTS Unit
Supply Fitting