Troubleshooting

 

PROBLEM

 

CAUSE

 

CORRECTION

1.  Pressure Drop

A. Sediment pre-filter clogged

B. Flow regulator

A.   Replace filter cartridge with appropriate 5 

micron cartridge.

Note: check source water supply as fluctuations 
may occur in source pressure
B.  Flow regulator will result in pressure drop when 

approaching full flow.

2.  High Bacteria Counts

A. Quartz sleeve is stained or dirty

B. Change in feed water quality

C.  Contamination in water lines after UV 

system

D.  Possible break-through of sediment 

through pre-filter

A.   Clean sleeve with scale cleaner and elimi-

nate source of staining problem (ie. soften 
hard water, see page 5-6).

B.  Have source water tested to ensure that 

water quality is still within allowable limits for 
this system.

C.  It is imperative that effluent water stream be 

shocked with chlorine (bleach) before water 
leaves UV system - disinfection system must 
have a bacterial free distribution system to 
work effectively (see page 4).

D.  Have source water tested for turbidity - may 

need stepped filtration in order to catch all 
sediment entering water system (20 micron 
filter followed by UV system).

3.  Heated Product 

Water

A.  Common problem caused by infre-

quent use of water

A.   Run water until it returns to ambient tempera-

ture.

4. Water Appears Milky

A.  Caused by air in the water lines

A.   Run water until air is purged.

5. Unit Leaking Water

A.  Problem with o-ring seal on gland 

nuts

B.  Condensation on reactor chamber 

caused by excessive humidity and 
cold water

C.  Inadequate inlet/outlet port connec-

tions

A.   Ensure o-ring is in place, check for cuts or 

abrasions, clean o-ring, moisten with water/
lubricant and re-install, replace if necessary.

B.  Check location of disinfection system and 

control humidity.

C.  Check thread connections, reseal with 

Teflon® tape and re-tighten.

6.  System Shutting Down 

Intermittently

A.  Interrupted power supply

A.   Ensure system has been installed on its own 

circuit, as other equipment may be drawing 
power away from UV (ie. pump or fridge). 
UV system should not be installed on a circuit 
which is incorporated into a light switch.

7.  Lamp Failure Alarm 

On - New Lamp

A.  Loose connection between lamp 

and connector

B.  Moisture buildup in connector may 

keep lamp and connector from mak-
ing a solid connection

A.   Disconnect lamp from connector and recon-

nect, ensuring that a tight fit is accomplished.

B.  Eliminate chance of any moisture getting to 

the connector and/or lamp pins.

Содержание Buv-12

Страница 1: ...UAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System Buv 6 Buv 8 Buv 12 55003 0612 System Tested and Certified by NSF International against NSF ANSI Standard 55 for Disinfection Per...

Страница 2: ...bled and they are unable to reproduce Since the cell is now sterile or dead it is no longer a threat PURA Systems PURA recommends that all UV systems include pre filters to process the water before it...

Страница 3: ...nd warnings on the water disinfection system 10 If an extension cord is necessary a cord with a proper rating should be used A cord rated for less Amperes or Watts than the disinfection system rating...

Страница 4: ...that may be used for the installation Routine Maintenance It is important that any water treatment system be properly maintained to ensure consistent water quality The information provided on this pag...

Страница 5: ...I make sure that this is taken into consideration prior to any installation The system can either be installed vertically inlet port at the bottom Figure 1A or horizontally Figure 1B When selecting a...

Страница 6: ...ter from potentially entering the controller 5 Install the UV lamp and sleeve as outlined on pages 8 9 6 When all plumbing connections are made slowly turn on the water supply and check for leaks The...

Страница 7: ...the locations have passed the chlorine disinfection solution you will need to leave the solution sit for a period of 20 30 minutes Reinstall the pre filter cartridge into the filter and then flush the...

Страница 8: ...er being careful not to angle the lamp as it is removed from the chamber If the lamp is removed on an angle pressure will be applied on the inside of the quartz sleeve causing the sleeve to fracture S...

Страница 9: ...ction on page 8 9 Slowly turn on the water and pressurize the reactor to verify that there are no leaks 10 Reconnect to power source NOTE If the system is put on a temporary bypass or if it becomes co...

Страница 10: ...system 3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient tempera ture 4 Water Appears Milky A Caused by air in the water lines A Run w...

Страница 11: ...ance Data Sheet While testing was performed under standard laboratory conditions actual performance may vary This Class B system or component conforms to NSF ANSI 55 for the supplemental bactericidal...

Страница 12: ...rranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PROD...

Отзывы: