Pura Buv-12 Скачать руководство пользователя страница 1

INSTALLATION MANUAL & OWNER’S GUIDE

Stainless Steel Ultraviolet Water Purification System

Buv-6

Buv-8

Buv-12

55003.0612

System Tested and Certified by 

NSF International against NSF/

ANSI Standard 55 for Disinfection 

Performance, Class B

Содержание Buv-12

Страница 1: ...UAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System Buv 6 Buv 8 Buv 12 55003 0612 System Tested and Certified by NSF International against NSF ANSI Standard 55 for Disinfection Per...

Страница 2: ...bled and they are unable to reproduce Since the cell is now sterile or dead it is no longer a threat PURA Systems PURA recommends that all UV systems include pre filters to process the water before it...

Страница 3: ...nd warnings on the water disinfection system 10 If an extension cord is necessary a cord with a proper rating should be used A cord rated for less Amperes or Watts than the disinfection system rating...

Страница 4: ...that may be used for the installation Routine Maintenance It is important that any water treatment system be properly maintained to ensure consistent water quality The information provided on this pag...

Страница 5: ...I make sure that this is taken into consideration prior to any installation The system can either be installed vertically inlet port at the bottom Figure 1A or horizontally Figure 1B When selecting a...

Страница 6: ...ter from potentially entering the controller 5 Install the UV lamp and sleeve as outlined on pages 8 9 6 When all plumbing connections are made slowly turn on the water supply and check for leaks The...

Страница 7: ...the locations have passed the chlorine disinfection solution you will need to leave the solution sit for a period of 20 30 minutes Reinstall the pre filter cartridge into the filter and then flush the...

Страница 8: ...er being careful not to angle the lamp as it is removed from the chamber If the lamp is removed on an angle pressure will be applied on the inside of the quartz sleeve causing the sleeve to fracture S...

Страница 9: ...ction on page 8 9 Slowly turn on the water and pressurize the reactor to verify that there are no leaks 10 Reconnect to power source NOTE If the system is put on a temporary bypass or if it becomes co...

Страница 10: ...system 3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient tempera ture 4 Water Appears Milky A Caused by air in the water lines A Run w...

Страница 11: ...ance Data Sheet While testing was performed under standard laboratory conditions actual performance may vary This Class B system or component conforms to NSF ANSI 55 for the supplemental bactericidal...

Страница 12: ...rranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PROD...