background image

12

This section is only required when utilizing IR flashers or Receivers in your installation.

1 The IR ports at the ‘INFRARED’ box work as follows:

•  IN port (black) is a 35mm stereo socket that accepts an IR input signal coming into the matrix intended 

to be sent to another room over the HDBT output below It extends the IR signal from the matrix to the 

attached neo Receiver’s IR-Flasher port 

You can connect these ports directly to a 3rd party Control system processor/controller A P8-IR-

Optocable might be required 

 

•  OUT port (grey) is a 35mm stereo socket output designed to attach an IR Flasher to control the Source (Blu-

ray, STB, etc) connected to the HDMI input below The original IR signal can come from the  following: 

•  Any IR signal received by an attached neo Receiver will be routed back to the corresponding ‘IR OUT’ port, 

according to the video routing to that HDBT output – eg if the matrix is routing video from HDMI In #2 

on to HDBT out # 5, then the any IR signal received by the neo Receiver attached to HDBT port #5 will be 

routed and blasted out the matrix’s IR OUT port #2

2 The CONTROL port is designed for legacy control systems where direct IR input is required 

3 The GLOBAL is used for a control system to be able to see all IR signals from all zones We 

recommend using a P8-IR-Optocable for connectivity from this port to your control system 

The HDMI IR IN ports above the HDMI outputs are a little different:

•  INPUT port is only required when using an external HDBaseT extender It is designed to receive 

the incoming IR signal from the HDBaseT set connected to the HDMI output The IR signal will 

then be routed to the corresponding ‘IR OUT’ port on the matrix according to the video routing 

Note: 

If a display is connected locally (i.e. there is no HDBaseT extender set connected to HDMI output) then this IR 

INPUT port should generally not be required in an installation.

IR RECEIVER AND TRANSMITTER PORTS 

Содержание neo:4Pro

Страница 1: ......

Страница 2: ...ion 5 Panel Descriptions 6 Infrared Blaster Cable Pack 8 Neo Lite Receiver 8 Installation 9 IR Receiver And Transmitter Ports 12 Wiring Guidelines 13 Neo Web Interface 14 Monitoring Portal 24 EDID Man...

Страница 3: ...080p 60 4 4 4 up to 70 meters 230 feet With CEC control and support for multiple video control methods the neo 4Pro is the uncompromising solution for residential and commercial installations The Puls...

Страница 4: ...to Source Yes IR Receiver Port 3 5mm 5V stereo jack IR Transmitter Port 3 5mm 5V stereo jack Ethernet Ports 1 x RJ45 control only Available On Internet Yes thru the Pulse Eight s Remote Monitoring Por...

Страница 5: ...als or chemicals Having them in your electronic device can sometimes cause a signal error or degradation to the internal chips and circuitries Because we cannot accurately predict how or when they can...

Страница 6: ...No network cable is connected AMBER Flashing It discovers the IP address AMBER Solid The network has the IP but cannot ping the router GREEN Flashing The network cannot reach the internet GREEN Solid...

Страница 7: ...connect the power Ethernet Connect to network Required for connection to Web Interface Third Party Control and Cloud Remote Monitoring Portal Global IR Used for a control system to be able to see all...

Страница 8: ...being received IR Receiver RX The IR Receiver port black can used to distribute IR signals back to the matrix when connecting an IR Receiver IR Flasher TX The IR Flasher port grey is used to control t...

Страница 9: ...ompatible IR Flasher Emitter Transmitter cable to the IR Out port grey on the matrix and the IR bud placed over the source device s IR window 1 Connect the appropriate category cable Cat6 or higher re...

Страница 10: ...sink devices e g TVs directly via high speed HDMI cables Note Can also be used in conjunction with a Pulse Eight neo HDMI Extender Set sold separately for reaching further distances Connecting The HDM...

Страница 11: ...before it begins its initialization sequence Note The initialization process takes between 20 seconds and up to 2 minutes However it is possible that a rmware update may be available the rst time the...

Страница 12: ...o that HDBT output e g if the matrix is routing video from HDMI In 2 on to HDBT out 5 then the any IR signal received by the neo Receiver attached to HDBT port 5 will be routed and blasted out the mat...

Страница 13: ...13 WIRING GUIDELINES This is an example of a wiring diagram of the neo 4Pro...

Страница 14: ...he Web Interface to configure the matrix according to the installation s requirements The Web Interface can be accessed using a computer connected to the same router network as the matrix and by visit...

Страница 15: ...our Pulse Eight installations remotely in one place For more information refer to the Accessing the Monitoring Portal section in this manual Note If you do not already have an Installer Id then you wi...

Страница 16: ...er s web interface EDID Pro le Drop down menu to select an alternative EDID pro le for the selected Input See the EDID Management section of this manual for more information EDID Details This will bri...

Страница 17: ...lected output from the end user s web interface Source Filtering Toggle switches to select which inputs can be routed to the selected output display Link Status Indicates if the HDBT link is active Re...

Страница 18: ...your installation to identify potential faults The IR Noise Test will check to see if any unwanted IR noise is being received over a sustained period of time for each port Failing this test would ind...

Страница 19: ...All four of these Channels should be below the 40 line Otherwise the cable quality will be marked as Poor Also all four of these Channels should be within 3 of each other for example 35 36 35 34 Othe...

Страница 20: ...ther details It is possible to add the neo 4Pro matrix to your Alexa smart home setup in order to control the attached Sink and Sources using voice commands 1 Install the neo Alexa skill from Amazon o...

Страница 21: ...l does require a persistent network connection Discovery Tool You can download a discovery tool from your monitoring portal at http monitoring pulse eight com this program will run on Windows 7 or new...

Страница 22: ...ide button then enabling this function allows you to use a combination of keys on the remote instead to achieve the missing function IR Control IR Activity A useful test for IR activity The panel list...

Страница 23: ...urrent firmware version installed You may be asked for this information if you request support It also details the firmware versions for the HDBaseT components transmitters and connected receivers in...

Страница 24: ...etails including your Installer ID Under the My Installs tab you can add projects and assign your installed systems in order to easily access and monitor certain installations To create an install cli...

Страница 25: ...25 Once created you will then be able to assign systems to the install by clicking the Add button in the Products section This will then bring up a page with a dropdown menu to select a system...

Страница 26: ...t Uptime System Status Inputs System Status Outputs External Network Details Local Network Con guration System Commands Reboot Function My Products Under the My Products tab all your assigned Pulse Ei...

Страница 27: ...updates available for the system There is also a toggle switch to turn on Hot x Updates whereby updates are delivered automatically to the system Installation Report displays all crucial information...

Страница 28: ...support the resolutions supported by all the displays connected to the outputs Clone Display Copies the same EDID as TV attached to the output X UltraHD 4K 1080p 720p It sets the EDID to support 4K 1...

Страница 29: ...K that is then distributed to all connected displays Any legacy display supporting up to 1080p only will likely display an error or no picture When this occurs it is possible to use a separate 4K Down...

Страница 30: ...t TMDS clock of 340 MHz which is equivalent to 10 2 Gbps Any video format above this datarate such as 4K 60Hz 4 4 4 or 4K 60 HDR is not supported Picture snow HD noise signi es a failure to fully esta...

Страница 31: ...ighting and plasma screens may also interfere with IR signals Infrared Not Functioning 1 Make sure to use the compatible IR asher receiver for this video matrix 2 Check and see if the LED beside the I...

Страница 32: ...ts 2 year return to base for repair BRONZE IR Cables Brackets and our Tech Tools 1 year advanced replacements Pulse Eight Current Product Within the advanced replacement warranty year s 1 Contact supp...

Страница 33: ...nded in coverage for any such transfer 2 TOTAL SATISFACTION RETURN POLICY If you are the original purchaser of the Product and you are not satisfied with this product for any reason you may return it...

Страница 34: ...connected to your product may change from time to time Without limiting the generality of the disclaimers above all product information is provided for your convenience as is and as available Pulse e...

Страница 35: ...35 NOTES...

Отзывы: