ULTRATWIN (UL)
INSTRUCTION MANUAL
192
Stability Parameters
P1 and P2
Damping
Damping is used to damp the display, to enable it to keep up with the
process but ignore minor surface fluctuations.
P*870 Fill Damping
This parameter determines the
maximum rate
at which the unit will
respond to an
increase in level
. It should be set slightly higher than the
maximum vessel fill rate.
Default = 32.8084 feet/min.
P*871 Empty Damping
This parameter determines the
maximum rate
at which the unit will
respond to a
decrease in level
. It should be set slightly higher than the
maximum vessel empty rate.
Default = 32.8084 feet /min.
Indicator
P*872 Fill Indicator
This parameter determines the rate at which the LCD
fill
indicator activates.
Default = 32.8084 feet /min.
P*873 Empty Indicator
This parameter determines the rate at which the LCD
empty
indicator
activates.
32.8084 feet /min.
Rate
P*874 Rate Update
This parameter determines the way in which the rate is calculated. If set to
continuous
(
P*874
=
0
), then the rate is calculated and displayed
continuously, i.e. any change seen from shot to shot is calculated and
displayed, but if set to use
values
P*874
=
1(Default)
then the
values
set in
P*875
and
P*876
are used to calculate and display the rate.
P*875 Rate Time
This parameter is the period (in seconds) over which the material level rate
of change is averaged before the
Rate
Value
(
P8*77
) is updated. If the
Rate
Distance
(
P*876
) is exceeded before the
Rate Time
(
P*875
) has expired,
then the
Rate Value
(
P*877
) will be updated immediately.
Default = 60sec.